Problem
The interior lighting is
not working.
The refrigerating unit
switches on with
increasing frequency
and for longer
periods.
The "alarm" indicator
(figure "/3) lights up.
(it is too warm in the
appliance).
The green control
light (figure "/4) is
not lit.
Possible cause
The bulb is faulty.
The chest lid is being
opened frequently.
The ventilation
openings are
covered. Figure *
The chest lid is being
opened frequently.
Lots of food has been
placed in the freezer.
The ventilation
openings are
covered. Figure *
The appliance is
beside a heat source.
The appliance is
switched off.
Power failure; the
fuse protection has
been switched off;
the mains plug is not
firmly inserted.
Remedy
Replace the bulb:
1. Unplug the appliance from the
mains or switch off the circuit
breaker.
2. Remove the lamp cover, figure (.
3. Change the bulb (replacement
bulb: 220-240 V alternating
current, E14 socket, see faulty
light for the wattage).
Do not open the lid unnecessarily.
Remove any obstructions.
Do not open the lid unnecessarily.
Switch on SuperFreezing before
placing food in the freezer.
Remove any obstructions.
Maintain the minimum distance or
use an insulating plate.
Connect the mains plug.
Check whether there is power,
check the fuses.
en