Filter Disassembly - The Pool Factory APF325PRO Owner's Manual

Table of Contents

Advertisement

MAINTAINING YOUR FILTER
WARNING
This product should be installed
and serviced only by a qualified pool
professional.
Manual Air Relief shown open
Figure 5
O-RING
FILTER DISASSEMBLY INSTRUCTIONS
1. Turn off all system circulation pumps
and all electric power on the equipemt
pad.
2. Set all system valves in a position to
prevent water flow to the filter.
3. The manual air relief valve must be
placed in the OPEN position. (Fig 6)
4. Remove filter drain plug (Fig 4) and
drain water from filter.
5. Using 3/4" wrenches or hex sockets,
loosen and remove the clamp nut and
the clamp bolt. (Fig 5)
Figure 6
7
6. Holding both ends of the filter clamp
carefully spread the clamp ends.
Remove the clamp by lifting over the
upper filter body. Do not to drop the
clamp during removal, because the
clamp could be damaged. Do not strike
the clamp with metal tools as they can
damage the clamp.
7. Lift off upper filter body. Do not use the
pressure gauge to lift the upper filter
body.
REMOVING
CARTRIDGES
1. Remove the top Manifold, which is
exposed when the upper filter body i
removed. (Fig 4)
2. Remove the filter cartridge elements b
using slight rocking motion and lifting up.
3. Clean filter cartridge elements
DRAIN PLUG
WITH O-RING
MANIFOLD
LOWER BODY
Figure 4

Advertisement

Table of Contents
loading

Related Products for The Pool Factory APF325PRO

This manual is also suitable for:

Apf425proApf525pro

Table of Contents