5.3.

HUMIDITY CONTROL

5.3.1.
When the rooms humidity value is 3% lower than the set humidity on the machine, the compressor will shut down, the fan will delay
for 3 minutes and shut down; and when it's 3% higher than the humidity value set on the machine, both the fan and compressor will
operate.
5.3.2.
When the humidity is set at the minimum value, the machines default is to enter the continuous dehumidifying mode.
5.3.3.
Upon fault of the humidity sensor, it turns to the continuous dehumidifying mode.
5.3.4.
Upon fault of the coil sensor, it turns to the timing defrosting mode (See the defrosting mode).
5.3.5.
When it's shut down, the fan will run for 10 seconds.
5.4.

PROTECTION FUNCTION

5.4.1.
Once shut down, the compressor will take 3 minutes to start. Quick start is available for the first power-on.
5.4.2.
Power off memory: For abrupt power outage or accidental unplugging, the system will automatically return to the operating state right
before the 'incident', and continue at that state for the next power-on.
Full water protection: When the water tank is full, the dehumidifier automatically shuts down and enters the standby state, the
5.4.3.
indicator light "Full Water" on and buzzer alarms.
5.5.

DEFROSTING MODE

Defrosting mode
Automatic Defrosting
Defrosting faults
5.6.
TIMING AND ON/OFF FUNCTION
5.6.1.
When the machine is powered on, set timer for powering off; and when the machine is powered off, set timer for it to power on. Setting
timer for both powering on and off then initiates the cycle timer mode.
5.6.2.
Set timer for powering on: When it's powered off, press the "Timing" Button. As the "Timing On" icon flickers and the time set flickers
in relevant area, press "+" or "-" to adjust the timing. The dehumidifier will make a sound once the button is pressed. When the time set
increases or decreases by "1", holding the button for 2 seconds will continually increase or decrease the time. For non-action for 10s
when it's adjusted to the required value, the dehumidifier accepts the new setting and the "Timing On" icon flickers (Ranging from 0 to
24H, and 0H as default);
5.6.3.
Set timer for powering off: When it's powered on, press the "Timing" Button. As the "Timing Off" icon flickers and the time set flickers
in relevant area, press "+" or "-" to adjust the timing. The dehumidifier makes a sound once the button is pressed. When the time set
increases or decreases by "1", holding the button constantly for 2s can continually increase or decrease the time. For non-action for
10s when it's adjusted to the required value, the dehumidifier accepts the new setting and the "Timing Off" icon flickers (Ranging from
0H to 24H, and 0H as default);
© Jack Sealey Limited
Description
Sensor at normal state
Coil sensor faults
(E1 displayed)
Temp-damp sensor faults
Coil sensor and temp-damp
sensor faults
Original Language Version
A
Power Indicator Light
B
Water Tank Full Indicator Light
C
Timer Indicator Light
D
On/Off Set
E
Set Timer
F
Add to Set Time
G
Reduce Set Time
1. The compressor constantly run over 20 minutes, coil temperature below
0°C constantly over 30 minutes, it starts the defrosting mode.
2. Coil temperature over 5°C for a 90 second period, or defrosting time over
8 minutes, it has stopped defrosting mode.
1. When the ambient temperature is over 25°C, it will not start a defrosting
cycle;
2. When ambient temperature below than 25°C but higher than 15°C, the
compressor runs constantly for 30 minutes, it defrosts for 10 minutes of that
30 minute period;
3. When ambient temperature below than 15°C and higher than 4°C,
compressor runs constantly 20 minutes, it defrosts 12 minutes;
1. The compressor runs constantly over 20 minutes, coil temperature below
0°C constantly run over 20 minutes, it starts defrosting mode.
1. The compressor run constantly over 40 minutes, it defrosts 10 minutes;
2. Coil temperature over 5°C constantly over 90 seconds; or defrosting time
over 25 minutes, it stops defrosting mode.
SDH50.V3 Issue 1 30/03/2021