VISCA Camera-Issued Messages
Acknowledge/Completion Messages
Command Messages
Acknowledge
z0 4y FF
(y:Socket No.)
Completion
z0 5y FF
(y:Socket No.)
z = Device address + 8
Error Messages
Command Messages
Syntax Error
z0 60 02 FF
Command Buffer Full
z0 60 03 FF
Command Canceled
z0 6y 04 FF
(y:Socket No.)
No Socket
z0 6y 05 FF
(y:Socket No.)
Command Not Executable
z0 6y 41 FF
(y:Socket No.)
Network Change Message
Command Message
Network Change
z0 38 FF
Comments
Returned when the command is accepted.
Returned when the command has been executed.
Comments
Returned when the command format is different or when a command with illegal
command parameters is accepted.
Indicates that two sockets are already being used (executing two commands) and the
command could not be accepted when received.
Returned when a command which is being executed in a socket specified by the cancel
command is canceled. The completion message for the command is not returned.
Returned when no command is executed in a socket specified by the cancel command,
or when an invalid socket number is specified.
Returned when a command cannot be executed due to current conditions. For example,
when commands controlling the focus manually are received during auto focus.
Comments
Issued when power is being routed.