Basic Functions; Overview Of Functions - Sony FCB-EV7520 Technical Manual

Color camera module
Hide thumbs Also See for FCB-EV7520:
Table of Contents

Advertisement

Overview of Functions

The camera control is performed by VISCA
Commands.
Timing Chart
As VISCA Command processing can only be carried
out one time in a Vertical cycle, it takes the maximum
1V cycle time for an Acknowledge/Completion to be
returned.
If the Command/Acknowledge/Completion
communication time can be less than the 1V cycle
time, then every 1V cycle can receive a Command.
General Commands
Query Commands
1) 1V cycle times on each Monitoring Mode and Shutter Speed.
Monitoring Mode
1080p/60
1080p/59.94
1080p/30
1080p/29.97
1080i/60
1080i/59.94
720p/60
720p/59.94
720p/30
720p/29.97
1/60 sec
16 Byte
1080p/50
1080p/25
1080i/50
720p/50
720p/25
1/50 sec

Basic Functions

In general
• Power On/Off
Powers the camera on and off.
When the power is off, the camera is able to accept
the VISCA Commands although the screen is set
non-displayed.
• I/F Clear
Clears the Command buffer of the FCB camera.
• Address Set
VISCA is a protocol, which normally supports a daisy
chain of up to seven connected cameras via RS-232C
interface. In such cases, the address set command can
be used to assign addresses from 1 to 7 to each of the
seven cameras, allowing you to control the seven
cameras with the same personal computer.
Although the FCB camera does not support direct
connection of cameras in a daisy chain, be sure to use
the address set command to set the address whenever
a camera is connected for the first time.
• ID Write
Sets the camera ID.
• Mute
Blanks the screen and sends out a synchronizing
signal.
• Lens Initialize
Initializes the zoom and focus of the lens. Even when
power is turned on, it initializes the zoom and the
focus.