HS - Series Reverse Osmosis Processor
With Built-in Pre-treatment and Membrane Flush
HS-Series
Pressure Tank
Float Tank
Models
Installation, Operation
&
Maintenance Manual
Page 1 of 18

Advertisement

Table of Contents
loading

Summary of Contents for Watts HS Series

  • Page 1 HS - Series Reverse Osmosis Processor With Built-in Pre-treatment and Membrane Flush HS-Series Pressure Tank Float Tank Models Installation, Operation & Maintenance Manual Page 1 of 18...
  • Page 2 Before installing and/or operating Watts HS-Series Reverse Osmosis system, read this manual completely. Keep this manual available for future reference. Further information is available by contacting your local Watts distributor. Phone: (623)505-1512 Pressure Tank Atmospheric Tank Page 2 of 18...
  • Page 3: Table Of Contents

    TABLE OF CONTENTS Specifications Specifications Chart ……………………………… 4 Installation Membrane installation ………………………………. 5 Inlet Connection ………………………………………. 6 Permeate Line Connection …………………..……. 7 Pressure Tank Connection ……………………..…. 8 Atmospheric Storage Tank ………………………… 9 Plumb to Drain ………………………………………. 10 Operation Start Up …………………………………………………..11 Alarms …………………………………………………….12 Maintenance Quarterly Maintenance ………………………………13...
  • Page 4 Specifications Complete System Packages SPECIFICATIONS HS-450 HS-1000 HS-2400 HS-4800 HS-9600 HS-15000 DRY WEIGHT lbs. WET WEIGHT lbs 1700 1750 4000 4100 4900 FEED WATER COLD/Temp ½”/35°-70° ½”/35°-70° ½”/35°-70° ¾”/35°-70° ¾”/35°-70° 1”/35°-70° HOT/ Temp ½”/70°- ½”/70°-140° ½”/70°- ¾”/70°-140° ¾”/70°- 1”/70°-140° 140° 140°...
  • Page 5: Membrane Installation

    Membrane Installation Note: All Membrane Vessels are clearly marked with flow direction. Membrane “Brine Seal” is always facing the water entry to Vessel. Brine Seal Membrane Membrane Vessel Flow Direction Marking Page 5 of 18...
  • Page 6: Inlet Connection

    Inlet Connection HOT and/or COLD FEED WATER CONNECTION Hard plumb Hot and/or Cold water Connections into Blending Valve Using (L) Copper Pipe. Refer to table Below. Valve is marked with HOT and Cold connections. Recommend installing Ball Valves just prior to the Blending Valve. NOTE: Use only Teflon tape on all threaded pipe.
  • Page 7: Permeate Line Connection

    Note: Fittings are included with systems ordered as complete packages only! HS-450 – HS2400 ½” Tubing or PVC pipe HS4800 – HS15K 1” PVC Schedule 40 pipe Permeate Line Connection The HS Series permeate connection is on the bulkhead labeled “OUT TO TANK” Page 7 of 18...
  • Page 8: Pressure Tank Connection

    Pressure Tank Connection Recommended tubing size From bulkhead on unit to tank Note: Fittings are included with Systems ordered as complete packages only! HS450 - HS2400 HS-450 3/8” Flexible poly tubing acceptable. HS-1000 3/8” HS4800 – HS15,000 HS-2400 3/8” Schedule 80 PVC required. HS-4800 ¾”...
  • Page 9: Atmospheric Storage Tank

    Atmospheric Storage Tank Bulkhead & Fitting Systems HS-450 3/8” Plumb Drain Connection located on Bulkhead of RO system to floor HS-1000 3/8” drain, using table specifications below or appropriate air gap drain with minimum drain size of 1 1/4”. HS-2400 3/8”...
  • Page 10: Plumb To Drain

    If the HS-Series was ordered with the atmospheric storage tank, the three tank float switches have been installed at the factory. Check to insure the tank floats have not been damaged. 1. Connect the gray electrical cable containing four (4) wires from the M-Series control box to the corresponding electrical connection on the atmospheric tank.
  • Page 11: Start Up

    Start Up ü Ensure power switch (located on top of control Box). (#1) is in the OFF position. ü Plug the unit into an appropriate power supply. ü If installing a pressure Tank system, open the Ball Valve (#2) on the Bulkhead. ü...
  • Page 12: Alarms

    ALARMS HS-Series processors are equipped with audible alarms. 1. The Constant Tone signals lack of incoming water pressure. (-------------------------------------------------------- Constant Tone) • Check incoming feed pressure to ensure a minimum of 20 psi. • Water pressure below 20 psi will trigger alarm. Incoming feed water pressure must be raised.
  • Page 13: Maintenance

    Maintenance Quarterly Preventive Maintenance for Systems with complete Pre and Post treatment. The M-Series RO processor requires quarterly preventive maintenance consisting of replacing (3) pre-filters and post Filters if supplied. 1. Pre-filters are located on left side of RO processor. 2.
  • Page 14: Annual Maintenance

    Annual Preventive Maintenance Perform quarterly preventive maintenance. Include replacement of O-Rings. Replace RO membrane by loosen retaining clamp at top of stainless steel membrane vessel Carefully pry loose PVC end cap from stainless steel vessel. Pull membrane from vessel using pliers i necessary and discard.
  • Page 15 Annual Preventive Maintenance Lubricate O-Rings on both ends of the Membrane and PVC Vessel Cap with K-Y Jelly or other water soluble lubricant. *Vaseline or other petroleum based lubricants will damage rubber o-ring and cause leaks Insert new membrane into vessel with the Brine Seal on same position as the old one just removed.
  • Page 16: Warranty

    Serial Number are required for obtaining an RGA #. For warranty service, ship your water treatment device with the RGA # printed on the Shipping Label to Watts, freight and insurance prepaid, with proof of original purchase date. Watts will repair or replace the water treatment device and ship it back to you prepaid.
  • Page 17: Glossary Of Terms

    GLOSSARY OF TERMS Atmospheric tank: A storage container requiring additional delivery system to distribute stored water. Typically constructed of polyurethane or stainless steel. Used in situations where greater storage capacity is needed than offered by conventional pressure tanks. Auto By-Pass: A feature that allows tap water to be delivered to downstream demands in the event the RO processor is unable to meet demand.
  • Page 18 GLOSSARY OF TERMS (Continued) Permeate: That portion of the feed water which passes through the membrane to become product water. Permeate Line: Tubing or pipe used to transport purified (RO processed) water from processor to the storage tank. Pressure tank: A water storage device using a pressurized bladder that provides delivery pressure to down stream uses.

This manual is also suitable for:

Hs-450Hs-1000Hs-2400Hs-4800Hs-9600Hs-15000