Advertisement

LG

Air Conditioner

OWNER'S MANUAL
Type : Wall Mounted
Visit us at http://www.lgservice.com
IMPORTANT
• Please read this owner's manual carefully and thoroughly
before installing and operating your room air conditioner.
• Please retain this owner's manual for future reference after
reading it thoroughly.
LG

Advertisement

Table of Contents
loading

Summary of Contents for LG CS05AF

  • Page 1: Air Conditioner

    Air Conditioner OWNER'S MANUAL Type : Wall Mounted Visit us at http://www.lgservice.com IMPORTANT • Please read this owner's manual carefully and thoroughly before installing and operating your room air conditioner. • Please retain this owner's manual for future reference after reading it thoroughly.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS A. Safety Precautions ...3 B. Electrical Safety...6 Temporary Use of an Adapter ...6 Temporary Use of an Extension Cord ...6 Symbols used in this Manual...6 C. Product Introduction...7 Indoor Units ...7 Operation Indication Lamps ...7 Self-Diagnosis Function ...7 D.
  • Page 3: Safety Precautions

    Safety Precautions To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by the following indications. Meanings of symbols used in this manual are as shown below. Always use a power plug and socket with a ground terminal.
  • Page 4 Safety Precautions Indoor/outdoor wiring connections must be secured tightly and the cable should be routed properly so that there is no force pulling the cable from the connection terminals. • Improper or loose connections can cause heat generation or fire. Be sure to check the refrigerant to the used.
  • Page 5 Do not use the product for special purposes, such as preserving foods, works of art, etc. It is a consumer air conditioner, not a precision refrigeration system. • There is a risk of damage or loss of property. Do not touch the metal parts of the product when removing the air filter.
  • Page 6: Electrical Safety

    Electrical Safety Electrical Safety • This appliance must be properly grounded. To minimize the risk of an electrical shock, you must always plug into a grounded outlet. • Do not cut or remove the grounded prong from the power plug. •...
  • Page 7: Product Introduction

    Product Introduction Here is a brief introduction of the indoor and outdoor units. Please see the information specific to your indoor unit type. Indoor Units Standard Split Type Display panel LED indicators Plasma filter (Optional) Air filter Air outlet Louvers(Vertical blades) Operation Indication Lamps The display will be activated for 10 seconds during STARTing operaion or by pressing any button on the remote controller.
  • Page 8: Operating Instructions

    Operating Instructions Operating Instructions How to insert the Batteries 1. Remove the battery cover by pulling it according to the arrow direction. 2. Insert new batteries making sure that the (+) and (-) of battery are installed correctly. 3. Reattach the cover by sliding it back into position. NOTE 1.
  • Page 9: Wireless Remote Controller

    Wireless Remote Controller The controls will look like the following. Signal transmitter CANCEL AUTO CLEAN Flip-up door (opened) Operation Mode Cooling Operation Auto Operation or Auto Changeover Healthy Dehumidification Operation Heating Operation • Cooling Model( ), Heat Pump Model( NOTE To use the functions printed in blue at the bottom of the buttons press 2 button.
  • Page 10: Operation Mode

    Operating Instructions Operation Mode For cooling or heating operation set the desired indoor temperature by pressing the ROOM TEMPERATURE SETTING BUTTONS. For cooling the temperature can be set within 18°C~30°C and for heating the temperature range is 16°C~30°C. Set the fan speed with the remote controller. You can select the fan speed in four steps-low, medium, high and CHAOS by pressing the INDOOR FAN SPEED SELECTOR BUTTON.
  • Page 11: Healthy Dehumidification Operation

    Healthy Dehumidification Operation During Healthy Dehumidification Operation Healthy Dehumidification In this case, however, the setting temperature is not displayed on the remote controller and you are not able to control the room temperature either. To run the healthy dehumidification mode follow steps 1, and 2 and 4 (See operation mode) Auto Operation (Optional) In this operation the actual operating mode is automatically set by the...
  • Page 12: Jet Cool/Heat Operation

    Operating Instructions Jet Cool/Heat Operation Jet Cool function can be used to cool the room quickly in hot summer. When this function is turned on, the air conditioner runs in cooling operation mode with super high fan speed and 18°C setting temperature for 30 minutes for fast and effective cooling.
  • Page 13: Energy-Saving Cooling Mode (Optional)

    Energy-Saving Cooling Mode (Optional) Energy-saving cooling mode can save energy in cooling operation, because it can operate efficiently by setting body-adaptation time according to the change of time and temperature and adjusting desired temperature automatically . 1. Press the START/STOP BUTTON to start the unit. 2.
  • Page 14: Sleep Mode

    Operating Instructions Sleep Mode 1. Press the SLEEP MODE AUTO BUTTON to set the time when you want the unit to stop automatically. 2. The timer is programmed in one-hour increments by pressing the SLEEP MODE AUTO BUTTON 1 to 7 times. The sleep mode is available for 1 to 7 times.
  • Page 15: Vertical / Horizontal Airflow Direction Control

    Vertical / Horizontal Airflow Direction Control The up/down airflow (Vertical airflow) can be adjusted by using the remote controller. 1. Press the START/STOP BUTTON to start the unit. 2. Press CHAOS SWING BUTTON. 3. The louvers will swing up & down automatically.
  • Page 16: Wired Remote Controller (Accessory)

    Wired Remote Controller (Accessory) MODEL : PQRCVSA0 Please attach the inform label inside of the door. Please choose proper language depend on your country. Some functions may not be operated and displayed depending on the product type. Read Remote Controller's Owner's manual for detail operation method. 16 Air Conditioner OPERATION INDICATION SCREEN SET TEMPERATURE BUTTON...
  • Page 17: Maintenance And Service

    Maintenance and Service Before performing any maintenance, turn off the main power to the system, disconnect the circuit breaker and unplug the power cord. Clean the unit with a soft dry cloth. Do not use bleach or abrasives. Never use any of these •...
  • Page 18: Outdoor Unit

    Maintenance and Service Outdoor Unit The heat exchanger coils and panel vents of the outdoor unit should be checked regularly. If clogged with dirt or soot, the heat exchanger and panel vents may be professionally steam cleaned. NOTE Dirty or clogged coils will reduce the operating efficiency of the system and cause higher operating costs. Operation Tips! Do not overcool the room.
  • Page 19: Troubleshooting Tips! Save Time And Money

    Troubleshooting Tips! Save time and money! The air conditioner may be operating abnormally when: Problem Possible Causes The air conditioner is unplugged. The fuse is blown/circuit breaker is tripped. Power failure. conditioner does not start High voltage. Airflow is restricted. The air filter is dirty.
  • Page 20 20 Air Conditioner...
  • Page 21 P/No.: MFL63265201 Printed in Korea After reading this manual, keep it in a place easily accessible to the user for future reference.

This manual is also suitable for:

Cs07afCs09afCs12af

Table of Contents