Adjustment Standard (Base Unit); Check Point (Charger Unit); Adjustment Standard (Charger Unit) - Panasonic KX-TG1283JXS Service Manual

Table of Contents

Advertisement

KX-TG1283JXS / KX-TG1283JXT / KX-TCA122CXS / KX-TCA122CXT / KX-TCA121CXS / KX-TCA121CXT
8.4.

Check Point (Charger Unit)

Items
(A)
Charging Check
Note:
After the measuring, sock up the solder of TP.
The connection of adjustment equipment is as shown in Adjustment Standard (Charger Unit) (P.34).
8.5.

Adjustment Standard (Charger Unit)

When connecting the Simulator Equipments for checking, please refer to below.
8.5.1.
Flow Solder Side View
Note:
(A) is referred to Check Point (Charger Unit) (P.34)
Check
Point
-
1. Connect Charge Contact 12Ω/2W resistor between charge+ and charge-.
2. Measure and confirm voltage across the resistor is 2.85V ± 0.2V.
DC POWER
6V
TP3
GND (TP2)
D11
TP3
TP4
R12
Procedure
PbF
TP2
WHITE
PQUP11305Z
BLUE
TP1
12Ω/2W
TP1
Digital
(A)
Volt Meter
34
Check or
Replace Parts
D11, R11, R12
A
GND (TP2)