Pinnacle Climate Technologies Remington REM-80-OFR-O User's Manual & Operating Instructions

Pinnacle Climate Technologies Remington REM-80-OFR-O User's Manual & Operating Instructions

Kerosene radiant heater
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

CONSUMER: READ AND SAVE THESE INSTRUCTIONS
Locating Your Serial Number:
Your serial number can be found on a blue label on the left side cover. It will begin with the letter
"S" followed by 9 digits. For Example: S160901126. Have your Serial Number ready before calling
customer service at 866-676-1989.
DANGER
SERVICING THE HEATER. Be sure to comply with the instructions and warnings provided
with this heater. Failure to comply can result in fire or explosion that can cause property loss,
bodily injury, or loss of life. Only persons who can follow and understand these instructions
should operate or service this heater. If you need heater info; such as an operating manual,
labels, etcetera, contact Pinnacle Climate Technologies at 866-676-1989.
DANGER
PERMITTED ONLY FOR: THE TEMPORARY HEATING OF
ADEQUATELY VENTILATED BUILDINGS OR STRUCTURES UNDER
CONSTRUCTION, ALTERATION OR REPAIR. This is an unvented
portable heater that uses air (Oxygen) from within the area in which
it is used. Failure to provide adequate combustion and ventilation air
will result in asphyxiation, carbon monoxide poisoning, bodily injury or
death. Refer to "Ventilation" on Page 7.
MODEL NUMBERS:
REM-80-OFR-O / REM-125-OFR-O
GENERAL HAZARD WARNING:
READ AND UNDERSTAND ALL OF THE INSTRUCTIONS
IN THIS MANUAL BEFORE ASSEMBLING, STARTING, OR
NOT FOR USE IN RESIDENTIAL LIVING
AREAS OR IN ENCLOSED SPACES
WITHOUT ADEQUATE VENTILATION.
FOR OUTDOOR USE. INDOOR USE
1 Industrial Blvd #101, Sauk Rapids, MN 56379 USA • Toll Free
Fax: 320-251-2922 • Web:
KEROSENE RADIANT HEATER
User's Manual &
Operating Instructions
www.remingtonheater.com
• Email: info@pinnacleclimate.com
© 2018 Pinnacle Climate Technologies, Inc.
Factory ID: 001
U.S. Patent No. 9,644,863
(866) 676-1989
RGRF-403

Advertisement

Chapters

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Remington REM-80-OFR-O and is the answer not in the manual?

Questions and answers

Summary of Contents for Pinnacle Climate Technologies Remington REM-80-OFR-O

  • Page 1 Only persons who can follow and understand these instructions should operate or service this heater. If you need heater info; such as an operating manual, labels, etcetera, contact Pinnacle Climate Technologies at 866-676-1989. NOT FOR USE IN RESIDENTIAL LIVING...
  • Page 2: Table Of Contents

    THE INSTALLATION OF THIS HEATER SHALL COMPLY WITH THE REGULATIONS OF THE AUTHORITIES HAVING JURISDICTION. Look for this icon throughout the manual for helpful tips on how to assemble, use and clean your OFR heater. © 2018 Pinnacle Climate Technologies, Inc. Kerosene Radiant Heater User’s Manual...
  • Page 3: Safety Information

    OPERATION. DO NOT TOUCH. KEEP CHILDREN, ANIMALS, every 100,000 Btu/Hr (29 kW) heater rating. CLOTHING AND COMBUSTIBLES AWAY Refer to “Ventilation” on page 7 for further FROM HEATER. instructions. © 2018 Pinnacle Climate Technologies, Inc. Kerosene Radiant Heater User’s Manual...
  • Page 4: Specifications

    (BEHIND REMOVABLE COVER) 125-OFR-O TOP SAFETY GUARD RADIANT CONE HANDLE FRONT SAFETY GUARD RADIANT FUEL VISORS WHEEL ADJUSTMENT FRAME º KNOB (CAN TILT DRAIN UP TO 15°) WHEEL BOLT © 2018 Pinnacle Climate Technologies, Inc. Kerosene Radiant Heater User’s Manual...
  • Page 5: What's In The Box

    (see Figure 3) . shell ring. Attach with screws removed in step 1 (see Figures 4 and 5). Figure 3 Figure 4 Figure 5 Heat Shield © 2018 Pinnacle Climate Technologies, Inc. Kerosene Radiant Heater User’s Manual...
  • Page 6 5. Attach top safety guard using the two outer-most extra screws on the top of the radiant cone (see Figure 9). Note: Save the box and packaging materials for future storage. © 2018 Pinnacle Climate Technologies, Inc. Kerosene Radiant Heater User’s Manual...
  • Page 7: Operation

    - NEVER store Kerosene in the living space. Kerosene should be stored in a well ventilated area outside the living area. - NEVER store Kerosene in direct sunlight or near a source of heat. © 2018 Pinnacle Climate Technologies, Inc. Kerosene Radiant Heater User’s Manual...
  • Page 8 The power indicator lamp will light and Always keep outlet covered when not in use heater will ignite (see Figure 10). Electrical Outlet Power Switch 80-OFR-O Only Figure 10 Figure 11 © 2018 Pinnacle Climate Technologies, Inc. Kerosene Radiant Heater User’s Manual...
  • Page 9: Maintenance

    1/8 to 1/4 Re-gap the terminals to 0.140” (3.5 mm) of a turn counterclockwise to reduce the air (see Figure 12). pressure until the unit is operating properly. © 2018 Pinnacle Climate Technologies, Inc. Kerosene Radiant Heater User’s Manual...
  • Page 10 The fuel filter and oil filter should be cleaned 125-OFR-O Nozzle at least twice per heating season by rinsing Figure 14b it in clean Kerosene or diesel. Contaminated or old fuel could make cleaning necessary immediately. © 2018 Pinnacle Climate Technologies, Inc. Kerosene Radiant Heater User’s Manual...
  • Page 11: Wiring Diagram

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE WIRING DIAGRAMS 80-OFR-O AC 250V 3.15A ELECTRIC OUTLET AC 120V/60Hz 125-OFR-O © 2018 Pinnacle Climate Technologies, Inc. Kerosene Radiant Heater User’s Manual...
  • Page 12: Troubleshooting Guide

    1. Be sure pump pressure is adjusted correctly. Poor combustion and / or soot 2. Poor fuel quality. 2. Be sure Kerosene/ diesel is not old production. or contaminated. © 2018 Pinnacle Climate Technologies, Inc. Kerosene Radiant Heater User’s Manual...
  • Page 13: Exploded View

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE EXPLODED VIEW 80-OFR-O © 2018 Pinnacle Climate Technologies, Inc. Kerosene Radiant Heater User’s Manual...
  • Page 14: Parts List

    75-036-0460 Nipple 75-040-0610 Diffusion Cap 75-036-0500 Blower Motor Assembly 75-045-0200 Photocell 72-038-0200 Return Pipe 75-055-0100 Return Hose 75-024-0745 Electronic Pump Bracket 75-027-0255 Heat Shield 75-012-0320 Fuel Pressure Gauge 70-028-0200 © 2018 Pinnacle Climate Technologies, Inc. Kerosene Radiant Heater User’s Manual...
  • Page 15 NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE EXPLODED VIEW 125-OFR-O © 2018 Pinnacle Climate Technologies, Inc. Kerosene Radiant Heater User’s Manual...
  • Page 16 72-037-0350 Temperature Overheat Sensor 72-040-0100 Heat Plate 72-012-0400 Safety Guard 72-012-0200 Front Frame 72-042-0410 Top Safety Guard 72-012-0250 Radiant Visors 72-012-0220 72-035-0630 Radiant Cone Gaskets 72-035-0615 Burner Housing Assembly © 2018 Pinnacle Climate Technologies, Inc. Kerosene Radiant Heater User’s Manual...
  • Page 17: Limited Warranty

    9 digits. For Example: S160901126. Have your Serial Number ready before calling customer service at 866- 676-1989. Model #:________________________________ Serial #:________________________________ Serial Number Label Date of Purchase: ________________________ © 2018 Pinnacle Climate Technologies, Inc. Kerosene Radiant Heater User’s Manual...
  • Page 18 1 Industrial Blvd #101, Sauk Rapids, MN 56379 USA • Toll Free (866) 676-1989 Fax: 320-251-2922 • Web: www.remingtonheater.com • Email: info@pinnacleclimate.com © 2018 Pinnacle Climate Technologies, Inc.
  • Page 19 Solamente personas que puedan seguir y comprender estas instrucciones deben operar o dar servicio a este calentador. Si necesita información sobre el calentador, como un manual de operación, etiquetas, etc. comuníquese con Pinnacle Climate Technologies al 866-676-1989. NO DEBE USARSE EN ÁREAS HABITABLES RESIDENCIALES NI EN ESPACIOS ID de fábrica: 001...
  • Page 20 LA INSTALACIÓN DE ESTE CALENTADOR DEBE CUMPLIR CON LAS REGLAS DE LAS AUTORIDADES QUE TENGAN JURISDICCIÓN. Busque este símbolo en el manual para encontrar consejos útiles sobre cómo armar, usar y limpiar su calentador OFR. © 2018 Pinnacle Climate Technologies, Inc. Manual del usuario del calentador radiante de queroseno...
  • Page 21: Información De Seguridad

    100,000 BTU/h (29 kWh) que MANTENGA A NIÑOS, ANIMALES, ROPA Y genere el calentador. Consulte “Ventilación” en la COMBUSTIBLES LEJOS DEL CALENTADOR. página 7 para obtener más instrucciones. © 2018 Pinnacle Climate Technologies, Inc. Manual del usuario del calentador radiante de queroseno...
  • Page 22: Especificaciones

    RADIANTE PROTECCIÓN DE SEGURIDAD DELANTERA VISORES TAPA DE RADIANTES COMBUSTIBLE BASTIDOR DE PERILLA DE LAS RUEDAS º AJUSTE (PUEDE PERNO DE INCLINARSE RUEDA DRENAJE HASTA 15°) © 2018 Pinnacle Climate Technologies, Inc. Manual del usuario del calentador radiante de queroseno...
  • Page 23: Qué Hay En La Caja

    (vea la Figura 3). Sujete con los tornillos que retiró en el paso 1 (vea las Figuras 4 y 5). Figura 3 Figura 4 Figura 5 Escudo de calor © 2018 Pinnacle Climate Technologies, Inc. Manual del usuario del calentador radiante de queroseno...
  • Page 24 (vea la Figura 9). Nota: Guarde la caja y los materiales de empaque para cuando guarde la unidad posteriormente. © 2018 Pinnacle Climate Technologies, Inc. Manual del usuario del calentador radiante de queroseno...
  • Page 25: Funcionamiento

    área bien ventilada, fuera del espacio habitable. - NUNCA almacene el queroseno expuesto directamente a la luz solar ni cerca de una fuente de calor. © 2018 Pinnacle Climate Technologies, Inc. Manual del usuario del calentador radiante de queroseno...
  • Page 26 Siempre mantenga cubierto el tomacorriente y se encenderá el calentador (vea la Figura 10). cuando no lo use. Tomacorriente Interruptor de eléctrico encendido Sólo 80-OFR-O Figura 10 Figura 11 © 2018 Pinnacle Climate Technologies, Inc. Manual del usuario del calentador radiante de queroseno...
  • Page 27: Mantenimiento

    Después de extraer la bujía, limpie las terminales la unidad funcione adecuadamente. con una cepillo de alambre. Reajuste la separación de las terminales a 3.5 mm (0.140 pulg.) (vea la Figura 12). © 2018 Pinnacle Climate Technologies, Inc. Manual del usuario del calentador radiante de queroseno...
  • Page 28 Boquilla 125-OFR-O o diésel limpio. Si el combustible está contaminado o viejo, es necesario limpiar los filtros de inmediato. Figura 14b © 2018 Pinnacle Climate Technologies, Inc. Manual del usuario del calentador radiante de queroseno...
  • Page 29: Diagrama Eléctrico

    IMPRESOS DE REVISIÓN DE ERROR TIERRA INTERRUPTOR MOTOR DEL ANTIVUELCO SOPLADOR BUJÍA ENCENDEDOR PCI DE CONTROL FOTOCÉLULA RETORNO INTERRUPTOR DE ALIMENTACIÓN BOMBA SENSOR BAJO DE CALOR © 2018 Pinnacle Climate Technologies, Inc. Manual del usuario del calentador radiante de queroseno...
  • Page 30: Guía Para La Solución De Problemas

    1. Asegúrese que la presión de la bomba Mala combustión o producción esté ajustada correctamente. de hollín. 2. Mala calidad de combustible 2. Asegúrese que el queroseno/diésel no esté viejo ni contaminado. © 2018 Pinnacle Climate Technologies, Inc. Manual del usuario del calentador radiante de queroseno...
  • Page 31: Vista Detallada

    NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN VISTA DETALLADA 80-OFR-O © 2018 Pinnacle Climate Technologies, Inc. Manual del usuario del calentador radiante de queroseno...
  • Page 32: Lista De Piezas

    Conjunto del motor del ventilador 75-045-0200 Fotocélula 72-038-0200 Manguera de retorno 75-055-0100 Manguera de retorno 75-024-0745 Soporte de la bomba electrónica 75-027-0255 Escudo de calor 75-012-0320 Manómetro de combustible 70-028-0200 © 2018 Pinnacle Climate Technologies, Inc. Manual del usuario del calentador radiante de queroseno...
  • Page 33 NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN VISTA DETALLADA 125-OFR-O © 2018 Pinnacle Climate Technologies, Inc. Manual del usuario del calentador radiante de queroseno...
  • Page 34 Protección de seguridad 72-012-0200 Bastidor frontal 72-042-0410 Protección de seguridad superior 72-012-0250 Visores radiantes 72-012-0220 72-035-0630 Empaques del cono radiante Conjunto de la cubierta del quemador 72-035-0615 © 2018 Pinnacle Climate Technologies, Inc. Manual del usuario del calentador radiante de queroseno...
  • Page 35: Garantía Limitada

    O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN GARANTÍA LIMITADA Pinnacle Climate Technologies, Inc. garantiza este Si Pinnacle Climate Technologies, Inc. descubre que el calentador únicamente al comprador minorista original, artículo está en condiciones normales de funcionamiento como libre de defectos en materiales y mano de o que no está...
  • Page 36 1 Industrial Blvd #101, Sauk Rapids, MN 56379 USA • Llamada sin costo (866) 676-1989 Fax: 320-251-2922 • Sitio web: www.remingtonheater.com • Correo electrónico: info@pinnacleclimate.com © 2018 Pinnacle Climate Technologies, Inc.

This manual is also suitable for:

Remington rem-125-ofr-o

Table of Contents