Quick Links

REM-40-GFA-O / REM-60V-GFA-O / REM-125V-GFA-O / REM-150V-GFA-O
Locating Your Serial Number:
Your serial number can be found on a white label on the right side cover of your heater. It will begin
with the letter "G" followed by 9 digits. For Example: G123456789. Have your Serial Number ready
before calling customer service at 866-676-1989.
DANGER
SERIOUS BODILY INJURY AND PROPERTY LOSS OR DAMAGE FROM HAZARDS OF FIRE, EXPLO-
SION, BURN. ASPHYXIATION, CARBON MONOXIDE POISONING AND / OR ELECTRIC SHOCK.
ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD USE
OR SERVICE THIS HEATER. IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN
INSTRUCTIONS MANUAL, LABEL, ETC. CONTACT THE MANUFACTURER.
WARNING
CARDBOARD, A SAFE DISTANCE AWAY FROM THE HEATER AS REC-
OMMENDED BY THESE INSTRUCTIONS. NEVER USE THE HEATER IN
SPACES WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNE COM-
BUSTIBLES, OR PRODUCTS SUCH AS GASOLINE, SOLVENTS, PAINT
THINNERS, DUST PARTICLES OR UNKNOWN CHEMICALS.
MODEL NUMBERS:
CONSUMER: READ AND SAVE THESE INSTRUCTIONS
GENERAL HAZARD WARNING:
FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUC-
TIONS PROVIDED WITH THIS HEATER, CAN RESULT IN DEATH,
FIRE, BURN, INHALATION, AND EXPLO-
SION HAZARD. KEEP SOLID COMBUSTIBLES,
SUCH AS BUILDING MATERIALS, PAPER OR
PROPANE FORCED AIR HEATER
1 Industrial Blvd #101, Sauk Rapids, MN 56379 USA • Toll Free
Fax: 320-251-2922 • Web:
www.remingtonheater.com
User's Manual &
Operating Instructions
• Email: info@pinnacleclimate.com
© 2018 Pinnacle Climate Technologies, Inc.
Factory ID: 001
(866) 676-1989
RGGD-403

Advertisement

Chapters

Table of Contents
loading
Need help?

Need help?

Do you have a question about the REMINGTON REM-40-GFA-O and is the answer not in the manual?

Questions and answers

Summary of Contents for Pinnacle Climate Technologies REMINGTON REM-40-GFA-O

  • Page 1 BUSTIBLES, OR PRODUCTS SUCH AS GASOLINE, SOLVENTS, PAINT THINNERS, DUST PARTICLES OR UNKNOWN CHEMICALS. 1 Industrial Blvd #101, Sauk Rapids, MN 56379 USA • Toll Free (866) 676-1989 Fax: 320-251-2922 • Web: www.remingtonheater.com • Email: info@pinnacleclimate.com © 2018 Pinnacle Climate Technologies, Inc. RGGD-403...
  • Page 2: Table Of Contents

    ANSI Z83.7-2011/CSA 2.14-2011. CHECK WITH YOUR LOCAL FIRE SAFETY AUTHORITY IF YOU HAVE ANY QUESTIONS ABOUT APPLICATIONS. Other standards govern the use of fuel gasses and heating products for specific uses. Your local authority can advise you about these. © 2018 Pinnacle Climate Technologies, Inc. Propane Forced Air Heater User’s Manual...
  • Page 3: Safety Information

    100,000 Btu / Hr (29 kW) heater TOUCH. KEEP CHILDREN, ANIMALS, CLOTH- rating. Refer to “Ventilation” on page 8 for further ING AND COMBUSTIBLES AWAY FROM HEATER. instructions. © 2018 Pinnacle Climate Technologies, Inc. Propane Forced Air Heater User’s Manual...
  • Page 4: Unpacking

    2. Remove all items from carton used without alteration. 3. Check all items for shipping damage. If the heater is damaged, promptly inform dealer where you purchased the heater. © 2018 Pinnacle Climate Technologies, Inc. Propane Forced Air Heater User’s Manual...
  • Page 5: Specifications

    Specifications subject to change without notice. FEATURES Handle Outer Shell Guard Inner Shell Power Cord Height Controller Gas Valve Knob Base WHAT’S IN THE BOX Heater (1) Hose & Regulator Assembly (1) © 2018 Pinnacle Climate Technologies, Inc. Propane Forced Air Heater User’s Manual...
  • Page 6: Operation

    Tightly close the gas shutoff valve on the LP from the operating cylinder. cylinder after each use. – All fittings must be protected when disconnected from the LP cylinder. © 2018 Pinnacle Climate Technologies, Inc. Propane Forced Air Heater User’s Manual...
  • Page 7 Some LP cylinders have a bleed-OFF valve. This valve should be inspected for leaks after each Supply Valve Regulator Inlet Connector Hose Hose Propane Tank Figure 2 Figure 3 © 2018 Pinnacle Climate Technologies, Inc. Propane Forced Air Heater User’s Manual...
  • Page 8: Ventilation

    (2,800 sq. cm) for each 100,000 BTU / Hr (29 kW). of heater output. Provide a larger opening if more heaters are being used. © 2018 Pinnacle Climate Technologies, Inc. Propane Forced Air Heater User’s Manual...
  • Page 9: Storage/Maintenance

    WIRING DIAGRAMS 40-GFA Figure 6 60V-GFA / 125V-GFA / 150V-GFA © 2018 Pinnacle Climate Technologies, Inc. Propane Forced Air Heater User’s Manual...
  • Page 10: Troubleshooting Guide

    Heater stops running clear of obstructions. by itself. 2. Damaged control valve. 2. Replace control valve. 3. Dust or debris accumulated 3. Clean inside of heater. in heater. © 2018 Pinnacle Climate Technologies, Inc. Propane Forced Air Heater User’s Manual...
  • Page 11: Exploded View

    22-521-0001 22-521-0002 22-521-0002 22-521-0002 PCB Case 22-506-0001 22-506-0001 22-506-0001 22-506-0001 Valve Knob 22-516-0001 22-516-0001 22-516-0001 22-516-0001 Power Cord 22-131-0001 22-131-0001 22-131-0001 22-131-0001 Regulator Assembly 22-041-0004 22-041-0004 22-041-0005 22-041-0005 © 2018 Pinnacle Climate Technologies, Inc. Propane Forced Air Heater User’s Manual...
  • Page 12: Limited Warranty

    Pinnacle Climate Technologies, Inc. will repair or replace and return the item, freight pre-paid. If Pinnacle Climate Technologies, Inc. finds the item to be Locating Your Serial Number: Your serial number can be found on a white label on the right side cover of your heater. It will begin with the letter “G”...
  • Page 13 GASOLINA, DISOLVENTES, SOLVENTES DE PINTURA, PARTÍCULAS DE POLVO O SUSTANCIAS QUÍMICAS DESCONOCIDAS. 1 Industrial Blvd #101, Sauk Rapids, MN 56379 USA • Llamada sin costo (866) 676-1989 Fax: 320-251-2922 • Sitio web: www.remingtonheater.com • Correo electrónico: info@pinnacleclimate.com © 2018 Pinnacle Climate Technologies, Inc. RGGD-403...
  • Page 14 LOCALIDAD SI TIENE ALGUNA DUDA SOBRE EL USO DE ESTE CALENTADOR. Otras normas rigen el uso de gases combustibles y productos de calefacción para usos específicos. Sus autoridades locales pueden asesorarle sobre esas normas. © 2018, Pinnacle Climate Technologies, Inc. Manual del usuario del calentador de aire forzado de propano...
  • Page 15: Información De Seguridad

    ESTÉ EN FUNCIONAMIENTO. NO LO TOQUE. genere el calentador. Consulte “Ventilación” MANTENGA A NIÑOS, ANIMALES, ROPA en la página 8 para obtener más instrucciones. Y COMBUSTIBLES LEJOS DEL CALENTADOR. © 2018, Pinnacle Climate Technologies, Inc. Manual del usuario del calentador de aire forzado de propano...
  • Page 16: Desempaque

    3. Inspeccione todos los artículos por si tuvieran con este calentador debe utilizarse sin hacerle daños por el envío. Si el calentador está dañado, ninguna modificación. © 2018, Pinnacle Climate Technologies, Inc. Manual del usuario del calentador de aire forzado de propano...
  • Page 17: Especificaciones

    Coraza interior Controlador Perilla de control de altura de gas Base QUÉ HAY EN LA CAJA Conjunto de manguera Calentador (1) y regulador (1) © 2018, Pinnacle Climate Technologies, Inc. Manual del usuario del calentador de aire forzado de propano...
  • Page 18: Funcionamiento

    Cierre firmemente la válvula de corte de gas en el tanque de LP después de cada uso. – Todas las uniones deben protegerse cuando estén desconectadas del tanque de LP. © 2018, Pinnacle Climate Technologies, Inc. Manual del usuario del calentador de aire forzado de propano...
  • Page 19 Debe inspeccionar esta válvula para ver Válvula de suministro Regulador Conector de entrada Manguera Manguera Tanque de propano Figura 2 Figura 3 © 2018, Pinnacle Climate Technologies, Inc. Manual del usuario del calentador de aire forzado de propano...
  • Page 20: Ventilación

    (0.28 m ) por cada 100,000 BTU / h (29 kWh) de emisión del calentador. Si utiliza más calentadores, provea una abertura más grande. © 2018, Pinnacle Climate Technologies, Inc. Manual del usuario del calentador de aire forzado de propano...
  • Page 21: Almacenamiento / Mantenimiento

    CONDENSADOR AZUL BLANCO AZUL BLANCO NEGRO BLANCO NEGRO FUSIBLE VERDE CABLE ELÉCTRICO CONJUNTO DE LA PLACA AZUL DE CIRCUITOS IMPRESOS INTERRUPTOR TÉRMICO TIERRA (CORAZA) © 2018, Pinnacle Climate Technologies, Inc. Manual del usuario del calentador de aire forzado de propano...
  • Page 22: Guía Para La Solución De Problemas

    2. Perilla de control dañada. 2. Reemplace la perilla de control. 3. Hay polvo o restos de material 3. Limpie el interior del calentador. acumulados dentro del calentador. © 2018, Pinnacle Climate Technologies, Inc. Manual del usuario del calentador de aire forzado de propano...
  • Page 23: Vista Detallada

    22-506-0001 22-506-0001 22-506-0001 Perilla de la válvula 22-516-0001 22-516-0001 22-516-0001 22-516-0001 Cable eléctrico 22-131-0001 22-131-0001 22-131-0001 22-131-0001 Conjunto del regulador 22-041-0004 22-041-0004 22-041-0005 22-041-0005 © 2018, Pinnacle Climate Technologies, Inc. Manual del usuario del calentador de aire forzado de propano...
  • Page 24: Garantía Limitada

    NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN GARANTÍA LIMITADA Pinnacle Climate Technologies, Inc. garantiza este Si Pinnacle Climate Technologies, Inc. descubre calentador únicamente al comprador minorista original, que el artículo está en condiciones normales de como libre de defectos en materiales y mano de obra funcionamiento o que no está...