Installation (continued)
Surface Conduit Mount
Remove conduit plug from the bottom
of the fixture from the where conduit
will enter. (Fig. 2)
Make wiring connections inside the
fixture as per the instructions given
below.
Wiring Instructions
If necessary, strip 3/8" of insulation
from junction box or fixture (A) wires
(fig 3).
Connect fixture black wire to house
black wire, the (+) line, and fixture
white wire to house white wire, the (-)
common by twisting the exposed wires
together and using the wire nuts (BB).
Ensure no loose wires.
Connect house ground wire to the
green fixture ground wire, by twisting
the exposed wires together and using
the wire nuts (BB).
7
Securing the light fixture
on the mounting base
Replace the reflector on the mounting
base plate (D) using the two small
screws, using a philips screwdriver,
removed in the Step1.
Close the fixture by tightening the
mounting base tightening screw (C),
using a philips screwdriver, which was
removed earlier in Step 1. (Fig. 1)
Visit www.probrite.com/install for installation video tutorials and product support
(fig 2).
Conduit
(fig 3).
(+) LINE
BLACK
LIGHTING
(-) COMMON
WHITE
FIXTURE
GROUND
GREEN
TIP: Hold stripped ends near each other and
align any frayed strands (do not twist wires).
Push the wires into wire nut (BB) and use your
fingers to twist the wire nut clockwise until tight.
Check for tightness by pulling wires.
C
(fig 1).
8
Installation (continued)
8
Caulking around the
light fixture
Caulk around the mounting plate (D)
and surface with silicone sealant (not
included).
NOTICE: Failure to properly caulk around the
surface and mounting plate (D) could lead
to water damage and is not covered under
warranty.
Operation
1
Selecting Dusk-to-Dawn or
Switch-Activated control
OPTION 1: DUSK-TO-DAWN OPERATION
Dusk-to-dawn operation enables the light fixture to automatically turn
ON when dark outside and turn OFF when the sun rises, thus saving you
energy.
To enable dusk-to-dawn operation
remove temporary black label cover
D
and ensure the photocell (E) has no
cover on it and is unobstructed.
Ensure the switch powering the outlet
connected to the light fixture is turned
to the ON position and leave it ON
at all times to enable dusk-to-dawn
functionality to operate automatically.
TIP: To test if the light fixture (A) and pho-
tocell (E) works properly run power to the
fixture and cover the photocell to turn fixture
ON. Shine a light into the photocell to see if
fixture turns OFF.
NOTE: When attaching this fixture (A) to an
external, surface mount junction box, caulk the
inside of the light fixture before attaching to the
mounting plate (D).
(No cover on photocell for Dusk-to-
Dawn Operation)
NOTE: If photocell (E ) is located in an area
under heavy shade the photocell may not
detect enough light and may turn the light
fixture on.
9
Please call 1-844-507-5651 or email support@probrite.com for further assistance.
D
AUTOMATIC
NIGHTTIME ON
DAYTIME OFF
E