3. Inspect the alignment of the "C" (access) panels during the assembly process. Verify that their
removal and replacement allows adequate space and positioning within the openings and with the
adjacent panels prior to attaching any bracket to the concrete.
4. Set the "C" access panels and the "F" (side) post in place with about a 3/16" gap on each side of the
"C" panels as the roof is assembled.
A. Set the "D1" (roof) panel on a "B1-A-B2" (side-end-side) assembly. Using two (2) hex headed screws,
fasten the "D1" (roof) panel to the "B1-A-B2" (side-end-side) assembly through the holes provided
(Fig 1).
B. Insert an Inside Roof Clip into the "D1" (roof) panel at the "B#" panel studs (Fig. 1C). Using one (1)
hex headed screw for each, attach the clip to the "B#" panel studs as shown.
C. Repeat step 4A and 4B for the "D2" (roof) panel and second "B1-A-B2" (side-end-side) assembly.
The information contained herein is intended for the use of the individual(s) named above and those authorized to receive it. Dissemination, distribution
or copy of this information is strictly prohibited.
NOTE: model sizes and configurations vary, see the chart.