Copyright 2021 Entrotec Limited. All rights reserved. Installation Specification It is the responsibility of the installer to follow Entrotec’s installation and cable specification as well as ALL relevant wiring regulations. Failure to comply with Entrotec’s installation and cable specification may result in erratic operation of equipment and could invalidate any warranty.
Provision ......................... 11 Provisioning Systems without an Entrotec Connect Server .......... 11 Provisioning Systems with an Entrotec Connect Server ..........13 Provisioning Systems with an Entrotec Connect Server Installed Retrospectively ..14 Configure ........................15 Block Name ........................15 Video and Audio Settings ....................15 Lock Release Time ......................
Overview 2 Overview Call Panel 2.1.1 Front View 2.1.2 Back View FIGURE 2-1 FIGURE 2-2 DO NOT USE Security Fixings, M4, Tool Supplied RS485 to Door Controller Microphone Tamper Switch Panel Camera Relay Output Display Ethernet to Door Controller Speaker Alarm Inputs Keypad 12VDC from Door Controller PSU...
Factory Default Settings 4 Factory Default Settings Setting Default IP Address 192.168.1.110 Subnet 255.255.0.0 Gateway 192.168.1.1 Device Admin Code 8, 8, 8, 8, 8, 8 Block No. Door No. 8001 5 Assign an IP address 5.1.1 Configure Network Settings on Device Before initialising a Call Panel, the default IP address should be configured to avoid conflicts with other devices with the same default settings.
NOTE Settings differ between systems WITH and WITHOUT an Entrotec Connect Server. For systems without an Entrotec Connect Sever, one Call Panel on the system is assigned as the SIP server. Connect to Web Service and Initialise Device Connect a laptop or PC to the same network as the Call Panel.
Page 9
Initialise Enter a new admin password for the device and press Next. WARNING It is important to choose a secure password and manage it correctly. If a password is forgotten, the device may have to be restored to default settings. This may result in data loss. Enter a recovery email address (optional) and press Next.
Login to Call Panel 7 Login to Call Panel Connect a laptop or PC to the same network as the Call Panel. Assign your PC or laptop an IPv4 address from the same range used by the door entry system. iii.
For systems where a PRO-ECS is fitted, or will be fitted later, use section 8.2. For systems where no PRO-ECS will be fitted, use section 8.1. Provisioning Systems without an Entrotec Connect Server For systems without an Entronet Connect Sever, one Call Panel on the system is assigned as the SIP server.
Page 12
Provision Select SIP Server. FIGURE 8-2 Uncheck Enable, this disables the internal device SIP Server which is on as default. For Sever Type select VTO. vii. Enter the Main Call Panel IP Address, Port 5060. viii. Press Save. NOTE The device will reboot if the SIP Server is enabled or disabled. This might take up to 2 minutes. 8.1.2 Configure SIP ID Login to the Call Panel as described in section 7.
Uncheck Enable, this disables the internal device SIP Server which is on as default. For Sever Type select Express\DSS. Enter the Entrotec Connect Server IP Address, Port 5080. Optional - enter the Domain VDP, SIP Server Username and SIP Server Password.
Set the Door No. - each Call Panel on a block should have a unique number. Press Confirm. FIGURE 8-6 Provisioning Systems with an Entrotec Connect Server Installed Retrospectively When planning to install the ECS at a later stage, the door entry system can be configured so that the main door panel will work temporarily as the SIP server.
Configure 9 Configure Block Name Login to the Call Panel as described in section 7. Navigate to Local Settings > Basic. iii. Set the Block Name - the text displayed on the first line when the panel is in idle state. Press Confirm.
Configure Lock Release Time Login to the Call Panel as described in section 7. Navigate to Local Settings > Access Control > Local. iii. Set the Unlock Retry Interval and Unlock Time, for the desired lock release time. Press Save - these settings update the onboard relay parameters. FIGURE 9-3 Navigate to Local Settings >...
FIGURE 10-1 Enter the Password which must be a 6-digit number. WARNING It is important to choose a secure password and manage it correctly. iii. Enter the recovery Email, this can be set to support@entrotec.co.uk FIGURE 10-2 Press OK to save.
Page 18
Apartment Station Configuration 10.3.2 Configure Network Settings From the home screen, press and hold Settings for 5 seconds. FIGURE 10-3 When the Password Verification screen appears, enter the device admin password setup in during initialisation. iii. Press OK. FIGURE 10-4 The admin menu will open in the Network tab.
Navigate to the User Config tab. Enter the Flat No. a. Systems WITHOUT an Entrotec Connect Server, enter the desired Flat No. e.g. 23 b. Systems WITH an Entrotec Connect Server, enter the desired Flat No. followed by #0 e.g. 23#0. NOTE The #0 parameter identifies the apartment station as the Master within the same property.
Apartment Station Configuration 10.4.2 Configure Doors Navigate to the Door Config tab. Enter the details for the Main Call Panel and any Sub Call Panels. FIGURE 10-8 NOTE Password is the Call Panel Device Admin Password. iii. If the Enable switch is OFF set it to ON after making any changes. If the Enable switch is ON set it to OFF, then ON again.
The User Password can be changed or disabled to allow easier access to the user menu. 11 Device Registration NOTE This section is only for systems WITHOUT an Entrotec Connect Server where the function of the SIP Server is assigned to the main call panel. Required Info To register devices to the Main Call Panel (SIP Server), the following is required.
Page 22
Device Registration Enter the Flat No. Enter Nick Name if required, this is displayed at the Call Panel when scrolling the contacts. Press Save. FIGURE 11-2 Repeat steps viii-xi for additional Apartment Stations. 11.2.2 Register Sub Call Panels Login to the Main Call Panel as described in section 7. Navigate to System Settings >...
Page 23
Device Registration 11.2.3 Register IP Cameras Login to the Main Call Panel as described in section 0. vii. Navigate to System Settings > Camera Settings. viii. Choose the first unused entry and press Modify. FIGURE 11-5 Enter a user-friendly Camera Name. Enter the IP Address for the camera and device specific settings as required.
Device Registration Check Status Login to the Main SIP Server Call Panel as described in section 7. xii. Navigate to System Settings > Status. FIGURE 11-7 All SIP devices registered to the Main Call Panel are displayed. If a device has gone offline, it will display the last Off Time.
Page 25
Device Registration Device List IP Address Block ID SIP ID Type Description 192.168.1.111 8001 Call Panel Ashwood Court, Front Door...