Download Print this page

March Pumps TE-7.5-MD Series Manual

Pumps w/1 phase motor

Advertisement

Quick Links

DESCRIPTION & OPERATION: Series 7.5 are centrifugal magnetic drive pumps. See the parts list
for a breakdown of parts. Pumps are not self-priming, lack a suction lift, and thus require a flooded
suction. Pumps cannot be run dry because the impeller requires the liquid being pumped for
lubrication. The direction of motor rotation should be clockwise when facing the inlet of the pump.
For liquids with a specific gravity greater than water, have a higher viscosity, or for elevated
temperatures, a trimmed impeller may be necessary. For application assistance, contact March
Pump.
Model Abbreviations: K: Kynar, P: Polypropylene
ELECTRICAL: The motor is 1 phase 115/230 Volt 60 Hz, 110/220 Volt 50 Hz. The motor is U.L.
listed and rated as continuous duty.
CAUTION IN ASSEMBLY & DISASSEMBLY: The magnetic coupling in the pump is strong enough
to warrant caution. When servicing the pump, the attraction of the impeller magnet and drive magnet
may pull the impeller from your grasp. When assembling, hold onto the outer diameter of the impeller
vanes with both hands and gently engage the impeller into the magnet field. Hold the impeller firmly
and resist the magnetic attraction as you slowly put the impeller back in. The magnetic forces are
strongest between 1/3 to 2/3 of engagement and will diminish when the magnets become aligned.
Do not allow the impeller to snap into the rear housing, doing so may result in damage. Exercise
caution in placing any of the magnets near steel, tools, or other sensitive instruments as doing so
may result in damage or personal injury. When attaching drive magnet to motor shaft, position the
face of the drive magnet 5/32 inch above the face of the motor bracket.
SPECIFICATIONS
Product #
Inlet - Outlet
Max Internal Pressure
Max Liquid Temperature
Overall Size (H x W x L) 10" (25.4 cm) x 9.53" (24.2 cm) x 19.58" (49.47 cm) 10.13" (25.7 cm) x 9.53" (24.2 cm) x 20.93" (53.2 cm) 10" (25.4 cm) x 9.53" (24.2 cm) x 19.58" (49.47 cm) 10.13" (25.7 cm) x 9.53" (24.2 cm) x 20.93" (53.2 cm)
MODEL
Max Flow
Max Head
gpm lpm
ft
TE-7.5K-MD 82
310
85
36.8
TE-7.5P-MD 82
310
85
36.8
All specifications & data are based on pumping water & are intended as a guideline only. Specifications may vary with different motors.
TE-7.5K-MD
0156-0001-0200
2" MPT – 1-1/2" MPT
2" Inlet Flange – 1-1/2" Outlet Flange
60 psi (413 kPa)
190 °F (87 °C)
60 Hz
ELECTRICAL
psi
m
Ph
V
A
Hp
kW Rpm gpm lpm
115
22
26
1
2
1.491 3450 70.8 268
230
11
115
22
26
1
2
1.491 3450 70.8 268
230
11
Series TE-7.5-MD Pumps w/1 Phase Motor
TE-7.5K-MD with Flanges
0156-0001-0270
60 psi (413 kPa)
190 °F (87 °C)
50 Hz
Max Flow
Max Head
ELECTRICAL
ft
psi
m
Ph
V
100
59
25.6
18
1
200
100
59
25.6
18
1
200
TE-7.5P-MD
0156-0059-0400
2" MPT – 1-1/2" MPT
2" Inlet Flange – 1-1/2" Outlet Flange
60 psi (413 kPa)
190 °F (87 °C)
Threaded
A
Hp
kW Rpm
lbs
20
1.5 1.118 2850
64.80
10
20
1.5 1.118 2850
64.80
10
TE-7.5P-MD with Flanges
0156-0059-0470
60 psi (413 kPa)
150 °F (65 °C)
Packed Weight
Flanges
kg
lbs
kg
29.39
65.8
29.84
29.39
65.8
29.84

Advertisement

loading

Summary of Contents for March Pumps TE-7.5-MD Series

  • Page 1 Series TE-7.5-MD Pumps w/1 Phase Motor DESCRIPTION & OPERATION: Series 7.5 are centrifugal magnetic drive pumps. See the parts list for a breakdown of parts. Pumps are not self-priming, lack a suction lift, and thus require a flooded suction. Pumps cannot be run dry because the impeller requires the liquid being pumped for lubrication.
  • Page 2 Polypropylene, Ceramic, Viton, Carbon LIMITED WARRANTY: March pumps are guaranteed only against defects in workmanship or materials for a period of one year from date of manufacture pumping water. For the complete warranty and to register online go to www.marchpump.com/warranty-registration Explosion proof and special voltage motors are available upon special order.

This manual is also suitable for:

Te-7.5k-mdTe-7.5p-md0156-0001-02000156-0001-02700156-0059-04000156-0059-0470