Page 1
TE-5M-MD and TE-5MNS-MD Marked with CE DESCRIPTION: Series 5 are centrifugal magnetic drive pumps, eliminating the need for a shaft seal. All are serviceable with a screwdriver. OPERATION: Pumps are not self-priming, lack a suction lift, and thus require a flooded suction.
Page 2
TE-5MNS-MD: Polypropylene, Noryl, Buna N, 316 Stainless Steel, Carbon, Ceramic, Ceramic Magnet. LIMITED WARRANTY: March pumps are guaranteed only against defects in workmanship or materials for a period of one year from date of manufacture pumping water. For the complete warranty and to register online go to www.marchpump.com/warranty-registration For the General Installation Manual, see this link https://www.marchpump.com/wp-content/uploads/2019/07/march-pump-general-installation-guide-0750-040.pdf...
Safety Instructions & Preventive Maintenance Read this sheet and the appropriate pump instruction manual before installing and operating any pump. Failure to follow safety instructions may result in injury or death. Health Precautions These pumps utilize magnets. Any individuals with pacemakers, implanted defibrillators, electronic medical devices, metallic heart valves, or sickle cell anemia should consult a health care professional before working with these pumps.
Do not cover the motor. Check all electrical connections with the wiring diagram found on the motor. Most March Pumps are not self-priming pumps. Liquid must flow naturally to the pump. Do not operate the pump until liquid is inside of the pump. Never run the pump dry.
Assembly/Disassembly Magnets Magnets on specific models may be strong enough to pull the wet end and motor end quickly together during assembly or disassembly. WARNING: Do not put fingers between the two mating surfaces (between impeller magnet and/or impeller vanes and the rear pump housing) during assembly or disassembly, especially for the 7.5, 8, and 10 Series.
Draining the Pump 1. Wear appropriate safety gear. 2. Disconnect the power. 3. Close suction and discharge valves. 4. Remove pipe/hose/tube from suction and discharge. 5. Unscrew/untighten fasteners from wet end. 6. Direct outlet downward into appropriate container. NOTE: Observe local laws and regulations for handling and disposing hazardous liquids. Do not get motors wet.
Vibration/Noise Motor not properly secured. • Piping not properly secured. • Pump cavitation from improper suction. • • Drive magnet rubbing against rear housing. Warranty Please see Warranty Page on March Website. www.marchpump.com/warranty-registration 0750-0984-1000 R3 (Revised 01/17/2024) - 5 -...