JOYTECH DET-1013b Owner's Manual

JOYTECH DET-1013b Owner's Manual

Infrared ear thermometer

Advertisement

Quick Links

Owner's Manual
Infrared Ear Thermometer
DET-1013b
Model
Contents
Introduction
......................................................02
Lcd Display Introduction ......................................... 04
............................................... 05
..............................................08
....................................................19
.....................................................23
.................................................24
.............................................................26
.............................................................27
.............................................................28
FCC Information .....................................................29
1
........................................... 03
............................ 06
................................. . 09
..........................................11
.................................17
.............................................20
..........................................22
Introduction
The DET-1013b thermometer is specifically designed for safe use
in the eardrum. The Infrared Ear Thermometer is a device capable
of measuring people's body temperature by detecting the intensity
of infrared light emitted from the ear canal of human. It converts
the measured heat into a temperature reading displayed on the LCD.
When properly used, it will quickly assess your temperature in an
accurate manner. The infrared thermometer is intended for the
intermittent measurement of human body temperature by people
of all ages.
Please read all instructions carefully and thoroughly
before using this product.
Warning:
1.
This thermometer is intended for home use only.
It's not meant to replace a visit to the doctor. Please
consult with doctor if you have health concerns.
2. There is no gender or age limitation for using infrared
ear thermometer.
3. To avoid inaccurate readings, always attach a new, clean
probe cover for each temperature reading.
4. Do not expose the thermometer to temperature extremes
(below -25℃/-13
or over 55℃/131
humidity (>95%RH).
5. This thermometer must only be used with this brand
thermometer probe covers.
6. Keep the battery away from children.
7.Remove battery from the device when not in operation for
a long time.
Document No.: JDET-1304-005
Article No.: 003
Version: Z
Date of Issue: 2020.12
) nor excessive
2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DET-1013b and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for JOYTECH DET-1013b

  • Page 1: Table Of Contents

    Date of Issue: 2020.12 Contents Introduction Introduction ............02 The DET-1013b thermometer is specifically designed for safe use in the eardrum. The Infrared Ear Thermometer is a device capable Product Description ........... 03 of measuring people's body temperature by detecting the intensity Lcd Display Introduction .........
  • Page 2: Product Description

    Product Description LCD Display Introduction 1. Probe Cover 2. Probe 3. Test Button 4. Mode Button 5. Battery Cover 6. Setting Button AM and PM sign in Time mode Time and date Low voltage sign Bluetooth Sign Memory mode Object temperature mode Voice sign Unit sign: ℃...
  • Page 3: Body Temperature

    Ear Thermometer Advantages Body Temperature Clinical studies have shown that the ear is an excellent site for temperature measurement because temperatures taken in the ear reflect the body s core temperature. Body temperature is regulated by the hypothalamus, which shares the same blood supply as the tympanic membrane.
  • Page 4: Illustration For Use

    Illustration For Use Illustration For Use To measure ear temperature: 3. Insert the probe along the ear canal as deep as possible into the ear as depicted in Figure 3. Then press the Test BUTTON once To achieve accurate readings, make sure a new, clean probe cover to start the measurement.
  • Page 5: Temperature Taking Hints

    Illustration For Use Illustration For Use Illustration For Use Bluetooth requirements Match your thermometer with a Smart Device 1. If this is your first time using it, bind first.Open "SETTING" The thermometer requires a bluetooth device with: . Bluetooth 4.0 or later menu,choose“Bind and unbind device"...
  • Page 6: Memory Mode

    Care And Cleaning Memory Mode 1. The Memory Mode can be accessed ether in ear mode or object 1. Probe covers are intended for single use only! mode: Absent, damaged, perforated, or soiled probe covers can lead to When the thermometer has been turned on and followed by inaccurate temperature readings.
  • Page 7: Specifications

    Specifications Troubleshooting Ear mode: 32.0℃~43.0℃(89.6℉~109.4℉) Object mode: 0℃~100℃(32℉~212℉) Measuring range Error message Problem Solution Measuring site Ear canal(Ear Mode) Take a measurement Oral (This thermometer converts the ear temperature to Measurement before until appears Reference body site display its “oral equivalent.”) thermometer is ready on the display.
  • Page 8: Service

    IEC 60601-1(Safety) standards. And the manufacturer is – to report unexpected operation or events. ISO 13485 certified. Manufacturer: JOYTECH HEALTHCARE Co., Ltd. Thermometer is warranted by manufacture to be free from defects in No.365, Wuzhou Road, Yuhang Economic Development Zone, Hangzhou city, 311100 Zhejiang,China...
  • Page 9: Electromagnetic Compatibility Information

    Electromagnetic Compatibility Information Electromagnetic Compatibility Information The device satisfies the EMC requirements of the international standard IEC 60601-1-2.The requirements are satisfied under the conditions described in the table below.The device is an electrical medical product and is subject to special precautionary measures with regard to EMC which must be published in the instructions for use.Portable and mobile HF communications equipment can affect the device.Use of the unit in conjunction with non-approved...
  • Page 10 Electromagnetic Compatibility Information Electromagnetic Compatibility Information Table 3 continued NOTE 1At 80 MHz and 800 MHz, the higher frequency range applies.NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people. a The ISM(industrial, scientific and medical) bands between 0,15 MHz and 80 MHz are 6,765 MHzto6,795 MHz;13,553 MHz to 13,567 MHZ;26,957 MHz to 27,283 MHz;...

Table of Contents