Summary of Contents for Digital Security Controls WLS9000
Page 1
WLS9000 Integral Wireless Alarm System DRAFT Manual Revision 0.01 – Sept 30th, 1999 WARNING: THIS DOCUMENT IS THE PRIVATE PROPERTY OF DIGITAL SECURITY CONTROLS LTD. IT CONTAINS CONFIDENTIAL INFORMATION AND IS NOT TO BE COPIED OR DISTRIBUTED.
Table of Contents 1.0 INTRODUCTION................................4 ..................................4 RODUCT NTENTIONS ................................5 ARDWARE ESCRIPTION WLS9000 Main Controller ................................5 Spread Spectrum Wireless................................5 Voice Prompting Components..............................5 Speaker Control ..................................5 Piezo......................................5 4.1.10 Remote Sounder ..................................5 4.1.11 Microphone for Central Station Talk/Listen ........................... 6 Terminal/Jack Connections.................................
Page 3
Downloading Software Version Support........................... 48 New Product Support and Structure ............................48 PC-LINK Support..................................48 New DLS Identifier..................................48 10.0 PROGRAMMING WORKSHEETS ..........................49 15.0 DOCUMENT REVISION ENDNOTES ........................75 Digital Security Controls Ltd. Private and Confidential Installation Manual DATE : 09/30/97 DRAFT...
1.1 Product Intentions The WLS9000 is an integrated wall or desk mounted security system. This panel is designed to conserve time in its installation, but yet retain a large variety of user-friendly features found in our modular systems. The WLS9000 incorporates a number of features not available in other DSC products, especially those that are intended to decrease installation time and increase end user friendliness.
Status LED Control Speaker Control The WLS9000 has an on-board speaker that is used for the annunciation of the voice prompts. There is a function key that provides volume control of these prompts. This functionality is handled by the Main Controller.
Function Key 8’s “Forward” Function. • Accessing the configuration wizard. • Hardwired Zone Configuration. 4.3 Plastics The WLS9000 requires all new plastics. The complete WLS9000 project comprises of the following plastics parts: • Front Housing (08-843) • Rear Housing w/Made in Canada (08-844) •...
5.2.1 New Function Key Types The WLS9000 has the following new Function Key Types: Status –The Status button on the WLS9000 may be pressed to annunciate the current status of the system. For example: “Zones are open. Zone 1. System is OFF. To turn ON, enter your access code. For more options, press star.”...
Hardwired Zone ‘Enrolling’ – The Wizard can also be used to enroll Hardwired zones. Serial Numbers X00001 and X00002 have been reserved for the two on-board zones. When a zone is enrolled in the Wizard as one of these zones, the WLS9000 will automatically assign the next available zone number and enter it in Section [020].
A method of selecting either the internal piezo/speaker or external remote sounder for the annunciation of alarms and Audio has been implemented in the WLS9000. This feature is to deter thieves from “homing in” on the source of the alarm and tampering with the WLS9000, thus resulting in a potential security breech.
WLS9000 will prompt: “Zone X” When the zone is restored, the WLS9000 will only sound a series of beeps similar to how Door Chime functions in our current products. If a label was programmed for the above Zone, the WLS9000 would annunciate (after the beeps): “Back Porch Window”...
Software department. 5.2.11 Recording of Custom Labels The WLS9000 has the capability of recording custom labels that may be assigned to a zone like any other ESCORT Label. Labels [246] to [253] are reserved for Custom Labels 1-8. These labels can be recorded via Installer’s Programming in Sections [701]-[708] using the following format: When in Sections [701]-[708], the ‘Record’...
ALARMS ANNUCIATED WHILE ARMED Zone Alarm conditions will be annunciated on all the WLS9000 by Verbally annunciating them as they occur. This also occurs for 24 Hour alarms while disarmed.
When a Pendant Test is executed, the WLS9000 will sound a steady 1 second tone. Note: the LED update is not kept up for the duration of the test. The WLS9000 will not be returned to the ready state for 30 seconds or when the “#” key is pressed.
15 24 Hour Medical is similar to 24 Hour Burglary except for System Event output type and SIA identifier. 16 24 Hour Panic is similar to 24 Hour Burglary except for System Event output type and SIA identifier. Digital Security Controls Ltd. Private and Confidential...
Entry Delay 2: (001-255) Seconds This value determines the Entry delay time for Delay 2 type zones. The default Entry Delay 2 time is 45 seconds. Exit Delay: (001-255) Seconds Digital Security Controls Ltd. Private and Confidential Installation Manual DATE : 09/30/97 DRAFT...
ON = Hardwired Zones are EOL Both hardwired zone loops on the WLS9000 use EOL supervision. OFF = Hardwired Zones are Normally Closed Both hardwired zone loops on the WLS9000 use Normally Closed loops. [2]-[3] Not Used [4] Tampers/Faults Annunciation Option...
Page 17
3 squawks per second for the final 10 seconds. OFF = No Bell Squawk On Exit Delay. Note: This audible option applies to ALL manual arming modes (Stay, Away, No Entry, etc) Digital Security Controls Ltd. Private and Confidential Installation Manual...
Page 18
When a valid [P] key alarm is generated, the Keypad buzzer will sound a series of 3 beeps to acknowledge the alarm and the bell or siren will sound for the length of Bell timeout. OFF = [P] Key Silent. Digital Security Controls Ltd. Private and Confidential Installation Manual...
Page 19
A telephone line trouble will generate a trouble indication, the Trouble LED will come ON and the keypad sounder will beep until a key is pressed. [016] Fourth System Options Code Digital Security Controls Ltd. Private and Confidential Installation Manual...
Page 20
OFF = WLSKeys Uses Access Codes. The WLS9000 will NOT accept the disarm keycode from an unidentified Wireless Key, thereby an access code must be associated to a WKEY for proper operation. [2] Verbal Door Chime Option ON = Verbal Door Chime is Enabled.
8.2.7 Remote/Local Annunciation Options (Section [017] Options 4 and 5) New toggle options have been added in Section [017] has been added to the WLS9000 that allows the Installer to have alarm/audio annunciation at the Local Unit, Remote Sounder, or both.
Page 22
OFF = The bell output will pulse when the zone is in alarm. [3] Chime Options ON = The WLS9000 will chime both when the zone is violated and when the zone is secured. Door Chime will work in both the armed and disarmed states.
If programmed, this reporting code will be transmitted to the monitoring station on Opening if an alarm occurred during the previous armed period. This reporting code is sent to the Alarm & Restoral call direction group of the System. Recent Closing Digital Security Controls Ltd. Private and Confidential Installation Manual DATE : 09/30/97...
Page 24
Similarly, an opening by these access codes will result in transmission of the corresponding reporting code. These reporting codes are sent to the Opening and Closing call direction group of the System. See also Duress Alarm Reporting Code. Auto Arm Cancellation Digital Security Controls Ltd. Private and Confidential Installation Manual DATE : 09/30/97 DRAFT...
Page 25
These reporting codes are sent to the System Maintenance Call Direction Group. Remote Sounder Trouble & Restoral If the WLS9000 does not receive a supervisiory signal for ten seconds, this trouble condition will be logged and communicated. These reporting codes are sent to the System Maintenance Call Direction Group.
Appendix A has all identifiers and the automatically constructed reporting codes. Note: XX represents the Zone/User Number. 00 represents a System Event which is not specific to a zone or user number. Digital Security Controls Ltd. Private and Confidential Installation Manual DATE : 09/30/97...
Page 27
Sounder / Relay System Peripheral Communications Protective Loop Sensor 4XX = Open / Close Group Open / Close Remote Access Access Control 5XX = Disables / Bypasses System Digital Security Controls Ltd. Private and Confidential Installation Manual DATE : 09/30/97 DRAFT...
Page 28
Fire Supervisory 24 Hour non-Burg SUPER - FIRE SUPERVISORY - # Low Water Pressure SUPER - LOW WATER PRESSURE - # Low CO2 SUPER - LOW CO2 Digital Security Controls Ltd. Private and Confidential Installation Manual DATE : 09/30/97 DRAFT...
Page 29
Remote Arm / Disarm OPENING - REMOTE CLOSING - REMOTE Quick Arm (Not Applicable) CLOSING - QUICK ARM Keyswitch O / C OPENING - KEYSWITCH CLOSING - KEYSWITCH Remote Access Digital Security Controls Ltd. Private and Confidential Installation Manual DATE : 09/30/97 DRAFT...
Each group can be assigned to the following Call Directions Option 1 1st Telephone Number (and 3rd Telephone Number if enabled for Alternate or Backup) Option 2 2nd Telephone Number Digital Security Controls Ltd. Private and Confidential Installation Manual DATE : 09/30/97 DRAFT...
Program the time of the test transmission in this section. Enter a 4-digit time using the 24 hour clock format (HH:MM). Valid entries are from 00 to 23 for the hours (HH) and 00 to 59 for the minutes (MM). To disable the test transmission, enter [9999] in this section. Digital Security Controls Ltd. Private and Confidential Installation Manual...
4 attempts. If unsuccessful, the system will switch to pulse (rotary) dialing for the final 4 attempts. OFF = DTMF Dial for all Attempts. If DTMF dialing is enabled, the WLS9000 will dial telephone numbers using DTMF dialing for all dialing attempts. [5] 3rd Phone Number Enabled / Disable ON = 3rd Phone Number Enabled.
Page 33
(ie Pager Format, etc). Reporting Code Entry Option ON Option OFF Digital Security Controls Ltd. Private and Confidential Installation Manual DATE : 09/30/97 DRAFT...
The system will not answer incoming calls using the Double Call routine unless the User enables the DLS window. This option can be enabled by turning Option 2 ON. [2] DLS Window Options ON = User Can Enable DLS Window. Digital Security Controls Ltd. Private and Confidential Installation Manual DATE : 09/30/97...
Page 35
This 4-digit Hexadecimal code allows the downloading computer to confirm the identity of the control panel. [405] Double-Call Timer This timer sets the amount of time that can be taken between calls when using Double Call to contact the WLS9000. Valid entries are 001 to 255 (seconds)
Note: If enabled, the manual bypassing of a zone will not bypass the tamper or fault states (DEOL). OFF = System Tampers Do Not Require Installer Reset. [5] Access Code Length Options ON = 6-digit Access Codes. Digital Security Controls Ltd. Private and Confidential Installation Manual DATE : 09/30/97 DRAFT...
Page 37
[5] I.D. Tone Options ON = I.D. Tone Enabled. After the telephone number is dialed, the panel will emit a tone (as specified by Option 6) for 500 Digital Security Controls Ltd. Private and Confidential Installation Manual DATE : 09/30/97...
Page 38
This is the time the panel waits between the first dialing attempt and the force dial attempt. Valid Entries are 001-255 seconds. Default is 020. [709] Busy Tone Duration Digital Security Controls Ltd. Private and Confidential Installation Manual DATE : 09/30/97...
[807] ESCORT Programming [000] Function Key Programming This section is used to program the Function Keys of the WLS9000. Upon entering this section, a 1 digit entry from 1 to 8 is required to select the function key to be programmed:...
Page 40
Status (Query) Pressing this key will result in the WLS9000 annunciating its current status. The user can then proceed to do other functions by pressing the corresponding keys on the WLS9000, or wait for the WLS9000’s audio prompting to time out.
To cancel the test mode, re-enter this section. If the user attempts to arm while in Walk Test, the WLS9000 will sound an error tone and prompt that the function is not available.
Event Buffer and most troubles can also be transmitted to the monitoring station. To view troubles, press [*] then [2]. The WLS9000 will verbally prompt you with the trouble conditions on the system. Troubles 1, 5, 6 and 7 can be expanded for more details by pressing the corresponding [1][5][6] or [7] key.
Page 43
6-8. Not Used Note: The WLS9000 does not prompt the individual troubles within Trouble #1. The user should call for assistance in the case of a “Service Required” trouble. Please note that the specific trouble will be logged in the Event Buffer.
Page 44
To turn the feature on or off, enter [*][4]. If the feature is being turned ON, the WLS9000 will prompt “Door Chime is ON”. If the feature is being turned OFF, the WLS9000 will prompt “Door Chime is OFF”.
Page 45
To erase a code, select the code and enter [*] as the first digit. If [*] is entered, the system will delete the code immediately and the user will be prompted to select another code. USER’S FUNCTIONS COMMAND Digital Security Controls Ltd. Private and Confidential Installation Manual...
Page 46
The system can be programmed to arm at the same time . Upon entry of this section, enter 4 digits for the 24 Hour Auto-Arm time. At the selected Auto-Arm time, the WLS9000 will sound for 1 minute to warn that an Auto-Arm is in progress. The siren can also be programmed to squawk once every 10 seconds during this warning period.
Page 47
This command is used to arm the system while at home. When the system is armed in this mode, the “Armed” light will be ON flashing and WLS9000 will prompt that there are zones bypassed. Once the panel is armed in this mode, using [*][1] will remove the bypass from the “Stay/Away”...
New Product Support and Structure The DLS files must be rearranged and to accommodate all new aspects of the WLS9000. These files must also remain relatively close to that of our Power line of products to ensure that this new panel keeps a “familiar feel” for those already acquainted with our products.
Exit Delay Enter 3 digits from 001-255 I___II___II___I Bell Cut-off Enter 3 digits from 001-255 [006] INSTALLER'S CODE Default 5555 I___II___II___II___I [007] MASTER CODE Default 1234 I___II___II___II___I Digital Security Controls Ltd. Private and Confidential Installation Manual DATE : 09/30/97 DRAFT...
Page 50
OFF I___I Option 6 Not Used OFF I___I Option 7 Bypass Status Displayed While Armed Bypass Status Not Displayed While Armed OFF I___I Option 8 Not Used Digital Security Controls Ltd. Private and Confidential Installation Manual DATE : 09/30/97 DRAFT...
Page 51
21 24 Hour Latching Tamper 22 Momentary Keyswitch 23 Maintained Keyswitch 24 Not Used 25 Interior Delay 87 Delayed 24Hr Fire (Wireless) 88 Standard 24Hr Fire (Wireless) Digital Security Controls Ltd. Private and Confidential Installation Manual DATE : 09/30/97 DRAFT...
Page 52
I____I I____I I____I I____I I____I [131] ZONE 31 I____I I____I I____I I____I I____I I____I I____I I____I [132] ZONE 32 I____I I____I I____I I____I I____I I____I I____I I____I Digital Security Controls Ltd. Private and Confidential Installation Manual DATE : 09/30/97 DRAFT...
Page 53
Zone 30 is Disabled OFF I___I Option 7 Zone 31 is Enabled Zone 31 is Disabled OFF I___I Option 8 Zone 32 is Enabled Zone 32 is Disabled Digital Security Controls Ltd. Private and Confidential Installation Manual DATE : 09/30/97 DRAFT...
Page 54
Zone 10 Alarm Restore I___II___I Zone 14 Alarm Restore I___II___I Zone 11 Alarm Restore I___II___I Zone 15 Alarm Restore I___II___I Zone 12 Alarm Restore I___II___I Zone 16 Alarm Restore Digital Security Controls Ltd. Private and Confidential Installation Manual DATE : 09/30/97 DRAFT...
Page 55
Zone 2 Tamper Restoral I___II___I Zone 6 Tamper Restoral I___II___I Zone 3 Tamper Restoral I___II___I Zone 7 Tamper Restoral I___II___I Zone 4 Tamper Restoral I___II___I Zone 8 Tamper Restoral Digital Security Controls Ltd. Private and Confidential Installation Manual DATE : 09/30/97 DRAFT...
Page 56
Closing by System Code 42 I___II___I Closing by Duress Code 34 I___II___I Partial Closing I___II___I Closing by System Code 40 I___II___I Special Closing I___II___I Closing by System Code 41 Digital Security Controls Ltd. Private and Confidential Installation Manual DATE : 09/30/97 DRAFT...
Page 57
I___II___I Not Used I___II___I System Test [353] WIRELESS MAINTENANCE REPORTING CODES I___II___I General Zone Low Battery Alarm I___II___I General Zone Low Battery Restore [360] COMMUNICATOR FORMAT OPTIONS Digital Security Controls Ltd. Private and Confidential Installation Manual DATE : 09/30/97 DRAFT...
Page 58
Test Transmission Cycle (land-line) (000-255 days)/(000-255 mins) I___II___II___I Zone Low Battery Transmission Delay (000-255 days) I___II___II___I Delinquency Transmission Delay (000-255 days/hours) [371] TEST TRANSMISSION TIME OF DAY Digital Security Controls Ltd. Private and Confidential Installation Manual DATE : 09/30/97 DRAFT...
Page 59
[402] DOWNLOADING COMPUTER'S TELEPHONE NUMBER (32 Digits) I__II__II__II__II__II__II__II__II__II__II__II__II__II__II__II__II__II__II__II__II__II__II__II__II__II__II__II__II__II__II__II__I [403] DOWNLOADING ACCESS CODE Default 9000 I__II__II__II__I Enter 4 Hexadecimal Digits. [404] PANEL IDENTIFICATION CODE Default 9000 I__II__II__II__I Enter 4 Hexadecimal Digits. Digital Security Controls Ltd. Private and Confidential Installation Manual DATE : 09/30/97 DRAFT...
Page 60
[801] NOT USED [802] AUDIO INTERFACE [10] Port Assignments, Zones 1-8 • Enter the nearest Intercom Port Number (01= Main Unit, 02= Remote Sounder, 00 = Not Used) Digital Security Controls Ltd. Private and Confidential Installation Manual DATE : 09/30/97 DRAFT...
Page 61
Incoming Sounds on Main Unit Enabled Incoming Sounds on Main Unit Disabled I___I Option 3 Incoming Sounds on Rem. Sndr Enab. Incoming Sounds on Rem Sndr. Disabled I___I Option 4-8 Not Used Digital Security Controls Ltd. Private and Confidential Installation Manual DATE : 09/30/97...
Page 62
NOTE: If any event is enabled for Talk/Listen In, Communications MUST be enabled. [55] Audio Duration Default I___II___I (Valid entries are 01-99 Seconds) [60] Telephone Ring Mask Default Option ON Option OFF Digital Security Controls Ltd. Private and Confidential Installation Manual DATE : 09/30/97 DRAFT...
Page 63
000000 I___II___II___II___II___II___I [32] Zone 32 Serial Number 000000 I___II___II___II___II___II___I HANDHELD KEYPAD SERIAL NUMBERS [33] Keypad #1 Serial Number 000000 I___II___II___II___II___II___I [34] Keypad #2 Serial Number 000000 I___II___II___II___II___II___I Digital Security Controls Ltd. Private and Confidential Installation Manual DATE : 09/30/97 DRAFT...
Page 64
000000 I___II___II___II___II___II___I [55] Wireless Key #15 Serial Number 000000 I___II___II___II___II___II___I [56] Wireless Key #16 Serial Number 000000 I___II___II___II___II___II___I Note: Serial Numbers are also Programmed via the Wizard. Digital Security Controls Ltd. Private and Confidential Installation Manual DATE : 09/30/97 DRAFT...
Page 65
Wireless Key Function Key 1 I___I I___I [62] Wireless Key Function Key 2 I___I I___I [63] Wireless Key Function Key 3 I___I I___I [64] Wireless Key Function Key 4 I___I I___I Digital Security Controls Ltd. Private and Confidential Installation Manual DATE : 09/30/97 DRAFT...
Page 66
Default Option ON Option OFF I___I Option 1 Zone 25 Supervision Enabled Zone 25 Superv. Disabled I___I Option 2 Zone 26 Supervision Enabled Zone 26 Superv. Disabled Digital Security Controls Ltd. Private and Confidential Installation Manual DATE : 09/30/97 DRAFT...
Page 67
Select an unused zone that will go open when a jamming signal is present. (Valid entry = 01 – 32, 00 = Jam Detect disabled) [805]-[806] NOT USED Digital Security Controls Ltd. Private and Confidential Installation Manual DATE : 09/30/97...
Page 68
Door Chime Disabled for Zone Openings I___I Option 03 Chime Enabled for Zone Closings Door Chime Disabled for Zone Closings I___I Option 04-08 Not Used (For Future Use) Digital Security Controls Ltd. Private and Confidential Installation Manual DATE : 09/30/97 DRAFT...
Page 69
Code always Req’d for Local Access No code Required for Local Access xxvii [030] ALARM TONE PERIOD FOR VERBAL ALARM Default I___II___II___I Valid entries are 001-255 seconds Digital Security Controls Ltd. Private and Confidential Installation Manual DATE : 09/30/97 DRAFT...
Page 70
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ Fire Zone Note: Zone Labels are also Programmed Via the Wizard! Digital Security Controls Ltd. Private and Confidential Installation Manual DATE : 09/30/97...
Page 71
RECORD CUSTOM LABEL #3 [704] RECORD CUSTOM LABEL #4 [705] RECORD CUSTOM LABEL #5 [706] RECORD CUSTOM LABEL #6 [707] RECORD CUSTOM LABEL #7 [708] RECORD CUSTOM LABEL #8 Digital Security Controls Ltd. Private and Confidential Installation Manual DATE : 09/30/97 DRAFT...
Page 72
[247] Custom Record #2 [248] Custom Record #3 [249] Custom Record #4 [250] Custom Record #5 [251] Custom Record #6 [252] Custom Record #7 [253] Custom Record #8 Digital Security Controls Ltd. Private and Confidential Installation Manual DATE : 09/30/97 DRAFT...
Page 73
SETBACK ZONES DEFAULT MORE SLOW ZERO DECREASE MONDAY SPECIAL DECEMBER MUSIC SPEECH DEVICES MARCH STAR DEVICE SAFE ENTER MESSAGE SCHEDULED EIGHT ELEVEN NEXT SPECIAL - FUNCTIONS FAST Digital Security Controls Ltd. Private and Confidential Installation Manual DATE : 09/30/97 DRAFT...
Page 74
[996][Installer’s Code][996] RESTORE RF FACTORY DEFAULT PROGRAMMING • ENTER [996] [INSTALLER’S CODE] [996] xxviii [999][Installer’s Code][999] RESTORE ALL WLS9000 FACTORY DEFAULT PROGRAMMING • ENTER [999] [INSTALLER’S CODE] [999] Digital Security Controls Ltd. Private and Confidential Installation Manual DATE : 09/30/97...
Moved Alarm Tone Period feature to the ESCORT (Section [030]). xxviii 1.01 Section 10.0 Exchanged Sections 992 and 999 (999 now defaults all; 992 defaults the Controller). Digital Security Controls Ltd. Private and Confidential Installation Manual DATE : 09/30/97 DRAFT...
Need help?
Do you have a question about the WLS9000 and is the answer not in the manual?
Questions and answers