Advertisement

Quick Links

USER MANUAL
DINgate DSO
Copyright © XEMEX
All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by
any means, electronic, mechanical, photocopying, recording or otherwise, without prior written permission of the publisher.

Advertisement

Table of Contents
loading

Summary of Contents for XEMEX DINgate DSO

  • Page 1 USER MANUAL DINgate DSO Copyright © XEMEX All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording or otherwise, without prior written permission of the publisher.
  • Page 2 User Manual - DINgate DSO OCUMENT Version: Status: Draft Version date: 1/10/2021 Filename: User Manual - DINgate DSO.docx Author: Luc Olieslagers Number of pages: ISTORY HANGES VERSION DATE DESCRIPTION 11/08/2021 Draft 01 October 2021 XEMEX Confidential Page 2 of 16...
  • Page 3: Table Of Contents

    User Manual - DINgate DSO ABLE ONTENTS INTRODUCTION ............................5 Scope ................................5 Target group ..............................5 Disclaimer ............................... 5 Applicable product versions ........................... 5 Intended usage ............................... 5 Technical assistance ............................5 Used symbols ..............................5 Safety precautions ............................6 TECHNICAL DESCRIPTION ........................
  • Page 4 User Manual - DINgate DSO CLEANING ............................. 16 LIFTING AND CARRYING........................16 MAINTENANCE AND SERVICE ......................16 01 October 2021 XEMEX Confidential Page 4 of 16...
  • Page 5: Introduction

    The information in this document is subject to change without notice and should not be construed as a promise by Xemex. Xemex assumes no liability for possible errors in this document. In no event shall Xemex be liable for direct,...
  • Page 6: Safety Precautions

    Do not operate the equipment other than indicated by the technical data. Always adhere to the following checklist: 1. Only qualified personnel or licensed electricians should install the Xemex DINgate DSO. The mains voltages of 230 Vac can be lethal! 2.
  • Page 7: Technical Description

    Mains power connection 230V The DINgate DSO module reads out the ABB B21 or B23 E-meter every 10 seconds and logs the data. Data can be readout using the DLMS protocol via a TCP/IP connection over LTE. The DLMS object model uses the SMR5 specification as a reference. Extra OBIS objects are added to provide LTE connection settings and diagnostics.
  • Page 8: Technical Specifications

    = 8E1 3.3 IR Interface Optical interface to connect to ABB meter without wire connection. Is an alternative for the RS485 Modbus connection between DINgate DSO and the ABB E-meter. 01 October 2021 XEMEX Confidential Page 8 of 16...
  • Page 9: User Interface - Leds

    SIM Insert / extract: push / push 3.6 LTE antenna connection The DINgate DSO is equipped with an LTE Cat-1 modem with GPRS fallback (DINgate DSO 1.0) or an LTE Cat-M modem (DINgate DSO 1.1) functionality. The supported frequency bands are: 3.6.1 DINgate DSO 1.0...
  • Page 10 User Manual - DINgate DSO RF common mode: EN 61000-4-6 Voltage dips: EN 61000-4-11 01 October 2021 XEMEX Confidential Page 10 of 16...
  • Page 11: Installation Instructions

    Failing to obey the ”Guidelines for safety and installation”, the guarantee no longer applies. 4.2 Mounting Mount the device in a DIN rail cabinet. 4.3 Electrical wiring diagram WARNING The DINgate DSO module power connection always needs to be protected with a circuit breaker. 01 October 2021 XEMEX Confidential Page 11 of 16...
  • Page 12: Data Connection With Abb B21 / B23 E-Meter

    User Manual - DINgate DSO 4.4 Data connection with ABB B21 / B23 E-meter 4.4.1 Via IR Interface Place de DINgate DSO module on the left side of the ABB E-meter so both IR interfaces make contact. 4.4.2 Via Modbus Interface B (-)
  • Page 13: Insert/Extract Sim Card

    To extract: push the SIM a bit further in the housing until it clicks and then release it to let it spring back. 4.6 LTE Antenna The antenna used to connect to the DINgate DSO needs to have an SMA male connector. The supported bands need to correspond with the bands provided by the SIM operator within the available LTE and GPRS bands.
  • Page 14: Configuration

    The DINgate DSO modules are preconfigured in production. Some configuration settings can be changed using specific tooling (remote or local via optical interface). This is described in document “Xemex product configuration via Gurux.docx” but out of scope for this document. 01 October 2021...
  • Page 15: Operating Instructions

    User Manual - DINgate DSO 5 Operating instructions The DINgate DSO module in combination with the ABB E-meter acts as small version of a smart meter. The unit supports the industry-standard protocol DLMS-COSEM for the WAN connection. This protocol implements the SMR5 application layer.
  • Page 16 User Manual - DINgate DSO 6 Cleaning Clean the unit with a slightly damp cloth and mild detergent. 7 Lifting and carrying Use care when lifting and carrying the product. 8 Maintenance and Service There are no serviceable parts inside.

Table of Contents