Frigidaire FEB755CESF Installation Instructions Manual

Electric built-in single and double oven models
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

INSTALLATION INSTRUCTIONS

ELECTRIC BUILT-IN
INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER
SINGLE AND DOUBLE OVEN MODELS
IMPORTANT NOTE TO INSTALLER:
instructions completely and carefully. Be sure to leave these instruc-
tions with the consumer.
IMPORTANT NOTE TO CONSUMER:
use and care book for future reference. Observe all governing codes
and ordinances. Save these instructions for local inspectors.
Your new wall oven has been designed to fit a wide variety of cutout
sizes to make the job of installing easier.
installation should be to measure your current cutout dimensions and
compare them to the cutout dimension chart for your model shown on
page 2. You may find that little or no cabinet work will be necessary.
1. CARPENTRY
Refer to Figures 1 or 2 for the dimensions applicable to
your model oven, and the space necessary to receive the
oven. The oven support surface may be solid plywood or
similar material, however the surface must be level from
side to side and from front to rear.
2. ELECTRICAL REQUIREMENTS
OBSERVE ALL GOVERNING CODES
AND LOCAL ORDINANCES
IMPORTANT:
SAVE THESE INSTRUCTIONS FOR
THE LOCAL ELECTRICAL INSPECTOR'S USE.
A. A three-wire or four-wire single phase 120/240 Volt,
60 Hz AC only electrical supply (or three-wire or four-
wire 120/280 Volt if specified on nameplate) is required
on a separate circuit fused on both sides of the line
(time-delay fuse or circuit breaker is recommended). DO
NOT fuse neutral. The fuse size must not exceed the
circuit rating of the appliance specified on the
nameplate.
Before you begin – read these
Keep these instructions with your
The first step of your
NOTE: Wire sizes and connections must conform with
the fuse size and rating of the appliance in accordance
with the National Electrical Code and local codes and
ordinances.
WARNING:
AN EXTENSION CORD SHOULD NOT BE
USED WITH THIS APPLIANCE. SUCH USE MAY RESULT IN
A FIRE, ELECTRICAL SHOCK, OR OTHER PERSONAL
INJURY.
B. The appliance should be connected to the fused
disconnect (or circuit breaker) box through flexible
armored or non-metallic sheathed cable. The flexible
armored cable extending from the appliance should be
connected directly to the junction box. The junction box
should be located as shown in Figure 1 with as much
slack as possible remaining in the cable between the box
and the appliance, so it can be moved, if servicing is ever
necessary.
C. A suitable strain relief must be provided to attach
the flexible armored cable to the junction box.
- 1 -
318064300 (9806) Rev. B
Printed in Canada

Advertisement

Table of Contents
loading

Summary of Contents for Frigidaire FEB755CESF

  • Page 1: Installation Instructions

    Observe all governing codes and ordinances. Save these instructions for local inspectors. Your new wall oven has been designed to fit a wide variety of cutout sizes to make the job of installing easier.
  • Page 2 49-1/4” 47-3/4” 11-1/2” 25-3/8” 6’ CABLE Allow at least 19-3/8” clearance for complete oven door opening as show in FIGURE 8. DO NOT INSTALL THIS OVEN IN A BASE CABINET WITH A COUNTERTOP ABOVE IT. PRODUCT DIMENSIONS AND CABINET WIDTH MODEL 24”...
  • Page 3: Electrical Connection

    Remove and lay aside the lower vent grille that is taped to the outer side panel of the oven. The grille will be fastened to the lower front of the oven after it has been installed in the cabinet. There is a 1-1/2” height adjustment on these models. (see figure 4) With this adjustment and a 1/2”...
  • Page 4: Checking Operation

    SERIAL PLATE LOCATION The Serial Plate is located along the side of the oven door in the open position. BEFORE YOU CALL FOR SERVICE Check to make sure the house fuses or circuit breaker for your oven are not blown or open.
  • Page 5: Instrucciones Para La Instalación

    INSTRUCCIONES PARA LA INSTALACIÓN HORNO ELÉCTRICO EMPOTRADO LA INSTALACIÓN Y EL SERVICIO DEBE DE HACERLOS UN INSTALADOR CALIFICADO DOBLE Y SENCILLO MODELOS DE HORNO AVISO IMPORTANTE PARA EL INSTALADOR: atención todas estas instrucciones. No se olvide de dejar estas instrucciones con el usuario.
  • Page 6 HORNOS SENCILLOS DE 24 Y 27 PULGADAS MÍNIMO 1-1/2 PULGADAS 28-1/32” 30-3/4” 31” 25-3/8” 6 PIES DE CABLE MÍNIMO 18 PULGADAS FIGURA 1 HORNOS DOBLOS DE 24 Y 27 PULGADAS MÍNIMO 1-1/2 PULGADAS 49 1/4” 47-3/4” 11-1/2” 25-3/8” 6 PIES DE CABLE FIGURA 2 Deje por lo menos 19-3/8 pulgadas de espacio para que la puerta se pueda abrir completamente, como se...
  • Page 7: Conexión Eléctrica

    3. AJUSTE DE LA ALTURA DEL HORNO Retire y deje a un lado la rejilla que está sujeta con cinta adhesiva al panel exterior del horno. Esta rejilla se sujetará a la parte baja frontal del horno, después de que este se haya instalado en el armario.
  • Page 8: Instalación

    ADVERTENCIA: Si está conectado a un sistema eléctrico de cuatro alambres (casa movible), el armazón del eletrodomestico NO TIENE QUE estar conectado al alambre neutro del sistema eléctrico de cuatro alambres. Separe el alambre blanco y el alambre pelado que salen del extremo final cable suministro...

Table of Contents