HITROL HLC-400 Instruction Manual

HITROL HLC-400 Instruction Manual

Level controller & alarm unit
Hide thumbs Also See for HLC-400:

Advertisement

Quick Links

HLC-400
HITROL CO., LTD.
HEAD OFFICE.FACTORY.R&D INSTITUDE
HITROL CO., LTD. 141, Palhakgol-gil, Jori-eup
Paju-si, Gyeonggi-do, Korea
TEL. : (+82)-31-950-9700
FAX. : (+82)-31-943-5600
www.hitrol.com
INSTRUCTION MANUAL
LEVEL CONTROLLER & ALARM UNIT
HLC-400
Doc. no. : HLC300N_IM_Eng_Rev.0.2
Issue date: 2020. 09
HITROL CO., LTD.
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HLC-400 and is the answer not in the manual?

Questions and answers

Summary of Contents for HITROL HLC-400

  • Page 1 HLC-400 HITROL CO., LTD. HEAD OFFICE.FACTORY.R&D INSTITUDE HITROL CO., LTD. 141, Palhakgol-gil, Jori-eup Paju-si, Gyeonggi-do, Korea TEL. : (+82)-31-950-9700 FAX. : (+82)-31-943-5600 www.hitrol.com INSTRUCTION MANUAL LEVEL CONTROLLER & ALARM UNIT HLC-400 Doc. no. : HLC300N_IM_Eng_Rev.0.2 Issue date: 2020. 09 HITROL CO., LTD.
  • Page 2: Table Of Contents

    WARNING is marked before carrying out the work. Y ou should be careful where CAUTION is marked to carry out the work. Y ou should be aware of where NOTICE is marked to carry out the work. HITROL CO., LTD.
  • Page 3: Overview

    HLC-400 HLC-400 is a Level Control & Alarm Unit that controls and alarms by combining with Overview the level sensor (HE, HQ, HR Type) of the storage of tank. The signal of the level sensor can function as the upper and lower alarm of liquid through HLC-400, and the product can be installed inside the control panel.
  • Page 4: Specifications

    E4 / AL.4 (Red) : L.L Detection Cable & Distance Def, 1.25 SQ @ Max. 300m Operating Temperature -20℃ ~ +60℃ Housing Material Dimensions 145mm x 90mm x 72mm Weight 325g Dimensions Unit: mm Actual product may have a tolerance slightly. HITROL CO., LTD.
  • Page 5: Wiring

    ~ 500m) and for low conductivity medium. (Non-recommendation cables may result in some differences in operating and level sensing distances.) Check the LED color after applying of power. ■ Power shall be applied after completing of installation. ■ Remove it with the power disconnected. HITROL CO., LTD.
  • Page 6: Safety And Environment

    - Please refer to the cable recommendations between the controller and the sensor for installation precautions (Page 5). 2) Float Type Level Switch - Check that the float floats normally. - Check the signal when the float operates normally. HITROL CO., LTD.
  • Page 7: Marking

    You can request A/S at our website or by contacting our headquarters. ■ Headquarters ․ Factory ․ Laboratory Contact ADDRESS: HITROL CO., LTD 141, Palhakgol-gil, Jori-eup, Paju-si, Gyeonggi-do, Korea T E L : 031-950-9700 (Headquarters & A/S) F A X : 031-943-5600 (Headquarters & A/S)

This manual is also suitable for:

Hlc-300n

Table of Contents