Advertisement

Quick Links

 
This quick start guide provides basic setup and operating instructions for the OEM TM-50. The intended use of the OEM TM-50
Taping Machine is to produce taped reels of individually sealed and consistently orientated components. Use of this equipment
in any other way is not recommended.
Work Area: The OEM TM-50 is designed to be operated in a temperature-controlled, light industrial setting. The machine
should be mounted on a flat, dry, stable surface in a well-lit area. Choose a mounting area that is at least 72" x 30" to provide
sufficient space for the assembled machine.
6
2
3
4
Front View
1. Cover Tape Arm
2. Take-up Spindle
3. Take-up Arm
Physical Specifications: Height: 18 inches (46 cm), Width: 42 inches (107 cm), Depth: 18 inches (46 cm), Weight: 105 lbs. (48 kg)
Power Required: 115/230 VAC, 50-60 Hz; 1.1 Amp, 120 Volts; .6 AMP, 220 Volts
Operating Environment: Operating Temperature: 0°C - 50°C (32°F - 122°F), Maximum Humidity: 90% non-condensing
 
Detailed User's Guides which include maintenance instructions, spare parts lists and troubleshooting information are available
on the V-TEK, Inc. website:
Contact Information
V-TEK, Inc.
751 Summit Ave
Mankato, MN 56001
D291720.5c 
OEM TM-50 Quick Start Guide
See pages 2-4 for Quick Start instructions.
1
4. Payout Arm
5. Tape Guides
6. Controller
Only qualified personnel with the proper technical training, experience working on this type of equipment
and awareness of the possible hazards should perform maintenance on the OEM TM-50.
The user is protected from moving parts and exposure to objects being ejected under pressure by a metal
enclosure. The OEM TM-50 should never be operated with the enclosure removed. There are no internal
parts that can be serviced by the user.
Always disconnect the machine from air and power supplies, placing the unplugged cables in clear view
before performing any maintenance tasks.
www.vtekusa.com.
TEL: (507) 387-2039
website:
http://www.vtekusa.com
email: service@vtekusa.com
5
Back View
7. Cable & Power Connections
8.
Air Regulator
Page 1 of 6 
7
8
 
Rev. 3, 10/17/17 

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the OEM TM-50 and is the answer not in the manual?

Questions and answers

Summary of Contents for V-TEK OEM TM-50

  • Page 1   This quick start guide provides basic setup and operating instructions for the OEM TM-50. The intended use of the OEM TM-50 Taping Machine is to produce taped reels of individually sealed and consistently orientated components. Use of this equipment in any other way is not recommended.
  • Page 2 OEM TM-50 Quick Start Guide   Assembly Attach the Cover Tape Arm Using a 3/16” hex wrench, remove the (2) 1/4” SHCS located on the backside of the loading track. Bolt the Cover Tape Arm (1a) to the track support bracket.
  • Page 3 OEM TM-50 Quick Start Guide   Mount the Controller Using a 5/32” hex wrench, remove the (2) 5/16” BHCS from the top of the (2) Controller Pedestals (6a). Attach the Controller Baseplate (6b) to the pedestals using the BHCS. Place the Controller (6c) on the controller baseplate.
  • Page 4 OEM TM-50 Quick Start Guide   Set up Front View 1. Power/E-Stop & Take-up Controls 2. Track Shafts 3. Payout Arm 4. Cover Tape Arm 5. Take-up Arm 6. Sealer Controls 7. Controller 8. Sealer Position Adjusters   Power On...
  • Page 5 OEM TM-50 Quick Start Guide   Load Carrier Tape Remove the Reel Lock (3a) from the payout reel spindle by pulling the two disks apart and sliding it off the spindle. Place a bulk Carrier Tape Reel (3b) on the payout arm, positioning it so the tape unwinds from the top and the sprocket holes are on the inside. Replace the reel...
  • Page 6 OEM TM-50 Quick Start Guide     Configure Controller Settings Set controller parameters for the current job, using the keypad to move through the controller Setup Menu. Select MODE, and then select HEAT or PSA seal.     Test Seal Use the foot switch to advance tape through the sealer.

Table of Contents