REPLACING UV LAMP AND SERVICING UV
SYSTEM:
NOTE : Avoid touching the sides of the quartz sleeve and lamp, handle by the ends
only.
1. Disconnect power.
2. Turn water off and open down stream of system to relieve pressure.
3. Remove the water proof strainer (1) and unscrew the aluminium / PVC nut (2).
4. Carefully withdraw lamp (4) approximately 2 inches from chamber (7).
5. While holding lamp end carefully, remove lamp socket (3).
6. Carefully withdraw lamp from chamber (7).
7. Carefully remove O-ring (5) from the end of the quartz sleeve (6).
8. Carefully remove the quartz sleeve (6).
9. To reinstall, follow step 8 through 1 in reverse.

MAINTENANCE

To operate the Solclear UV sterilizer properly and attain its maximum efficiency,
appropriate maintenance is to be performed as follows:
I.
Quartz sleeve cleaning or replacement:
• Quartz sleeve is to be cleaned every 6-12 months with glass cleaner.
• Quartz sleeve is to be replaced every 24 months.
II. UV lamp replacement is recommended every 8,000-9,000 hours (approximately
12 months for continous service) for Solclear 90 & 150, or 13,000 hours
(approximately 1.5 years of continous service) for Solclear 300 of operation.
Solclear UV Sterilizer I 09