Installation Instruction

The ballast has 3 ports:
1. Dry contact signal output port
1. The no. 1 port is a relay dry contact output. When the ballast is working normally, the dry
contact is shorted, otherwise the dry contact is open. The withstand voltage is 250V,
ampere rating is 5A. It can be connected to PLC, solenoid valve and others. If it is not
used, please put the threaded cap on to avoid humidity and dust.
2. The no. 2 port is power input port: standard power input port with 3pins. When plug the
power cable into the input port, please push the plug into deep bottom of the port to
have good contact.
3. The no. 3 port is the power output for UV lamp
# Note: please disconnect power before unplug all connectors.
There are two ways to mount the ballast: (1) with hanging plate and (2) double sided tape.
Digital panel display operation instruction
1. Press the button and hold it for 5 seconds, the timer will reset to the factory defaults.
2. Quick press the button, the LED shows the used time of the lamp, then quick press the
button again it shows the start-up times. If left idle for 2 seconds, the LED will return to
show the remaining time.
3. When the remaining time is less than 300 hours, the ballast will sound alarm, and the
LED will blink. Quick press the button, the ballast will stop sounding.
4. When the lamp life expired, the ballast sounds alarm, LED turns red, the lamp is turned off.
5. When no lamp is connected or the lamp is damaged, the ballast sounds alarm and LED
turn red.
6. When situation as item 4 or item 5 happens, please turn to a new lamp and reset
according to step 1 as above.
Toubleshooting for Electronic Ballast
No
Problem
When the ballast is connected to
1
power, there is no display on LCD.
When the ballast is connected to
2
power, the lamp is not lighted up,
but the ballast alarm sounds.
2. Power input port
Please check the power is connected
properly.
Please turn off power, check the connections
between the ballast and the lamp separately,
and tighten them again.
Solclear UV Sterilizer I 11
3. Lamp output port
Solution

Advertisement