Moving The Range - Whirlpool WGG745S0FE Owner's Manual

Double oven freestanding gas and dual fuel range
Table of Contents

Advertisement

Available languages

Available languages

4. Gas orifice spuds are stamped with a number on the side.
Replace the Propane gas orifice spud with the correct Natural
gas orifice spud.
A. Stamped number
Refer to the following chart for the correct Natural gas orifice
spud placement.
Natural Gas Orifice Spud Chart
Burner Rating
5,000 BTU
7,300 BTU
10,000 BTU
17,000 BTU
NOTE: Refer to the model/serial/rating plate located on the oven
frame behind the top right-hand side of the oven door for proper
sizing of spuds for each burner location.
5. Place Propane gas orifice spuds in the orifice spud bag.
IMPORTANT: Keep the Propane gas orifice spuds in case of
reinstallation with Propane gas.
6. Replace the burner base.
7. Replace burner cap.
8. Repeat steps 1 through 7 for the remaining burners.
Number
100AM
125AM
140AM
200AM

Moving the Range

WARNING
Tip Over Hazard
A child or adult can tip the range and be killed.
Install anti-tip bracket to floor or wall per installation
instructions.
Slide range back so rear range foot is engaged in the
slot of the anti-tip bracket.
Re-engage anti-tip bracket if range is moved.
Do not operate range without anti-tip bracket installed
and engaged.
Failure to follow these instructions can result in death or
serious burns to children and adults.
When moving range, slide range onto cardboard or hardboard to
avoid damaging the floor covering.
If removing the range is necessary for cleaning or maintenance:
For power supply cord-connected ranges:
1. Slide range forward.
2. Turn manual shutoff valve to the closed position.
3. Unplug the power supply cord.
4. Disconnect the gas supply tubing.
5. Complete cleaning or maintenance.
6. Reconnect the gas supply tubing.
7. Open the manual shutoff valve in the gas supply line.
8. Plug in power supply cord.
9. Slide range back so rear range foot is under anti-tip bracket.
10. Refer to the "Verify Anti-Tip Bracket Is Installed and Engaged"
section to verify engagement.
11. Check that range is level.
25

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents