Electrical Requirements (For Dual Fuel Models) - U.s.a. Only; Electrical Requirements (For Dual Fuel Models) - Canada Only - Whirlpool WGG745S0FE Owner's Manual

Double oven freestanding gas and dual fuel range
Table of Contents

Advertisement

Available languages

Available languages

Electrical Requirements (for Dual
Fuel models) - U.S.A. Only
WARNING
Electrical Shock Hazard
Electrically ground appliance.
Failure to do so could result in death, fire, or electrical
shock.
Be sure that the electrical connection and wire size are adequate
and in conformance with the National Electrical Code, ANSI/
NFPA 70-latest edition and all local codes and ordinances.
A copy of the above code standards can be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
WARNING: Improper connection of the equipment-grounding
conductor can result in a risk of electric shock. Check with a
qualified electrician or service technician if you are in doubt as to
whether the appliance is properly grounded. Do not modify the
power supply cord plug. If it will not fit the outlet, have a proper
outlet installed by a qualified electrician.
Electrical Connection
Check local codes and consult gas supplier. Check existing
electrical supply and gas supply. See "Gas Supply Requirements"
sections. It is recommended that all electrical connections be
made by a licensed, qualified electrical installer.
■ Range must be connected to the proper electrical voltage and
frequency as specified on the model/serial/rating plate. The
model/serial/rating plate is located on the right vertical surface
of the oven door frame.
■ This range is manufactured with a 4-wire power supply cord
rated at 240 V, 40 A, rated at 194°F (90°C) and investigated for
use with this range
Range
Rating*
120/240 V
120/208 V
8.8 - 16.5 kW
7.8 - 12.5 kW
16.6 - 22.5
12.6 - 18.5
kW
kW
10
Specified Rating of Power
Supply Cord Kit and Circuit
Protection
Ampere
Temp Rating
40 or 50
194°F (90°C)
50
194°F (90°C)
*The NEC calculated load is less than the total connected load
listed on the model/serial rating plate.
■ When a 4-wire, single phase 240 V, 60 Hz., AC only electrical
supply is available, a 40 A minimum circuit protection is
required on 30" (76.2 cm) ranges, fused on both sides of the
line.
■ A time-delay fuse or circuit breaker is recommended.
■ This range is equipped with a UL or CSA International Certified
Power Cord intended to be plugged into a standard 14-50R
wall receptacle. Be sure the wall receptacle is within reach of
range's final location.
■ Do not use an extension cord.
■ The wiring diagram is located on the back of the range or in a
clear plastic bag.
Electrical Requirements (for Dual
Fuel models) - Canada Only
WARNING
Electrical Shock Hazard
Electrically ground appliance.
Failure to do so could result in death, fire, or electrical
shock.
Be sure that the electrical connection and wire size are adequate
and in conformance with the CSA Standard C22.1, Canadian
Electrical Code, Part 1 - latest edition, and all local codes and
ordinances.
A copy of the above code standards can be obtained from:
Canadian Standards Association
178 Rexdale Blvd.
Toronto, ON M9W 1R3 CANADA
■ Check with a qualified electrical installer if you are not sure the
range is properly grounded.
Range
Rating*
120/240 V
120/208 V
8.8 - 16.5 kW
7.8 - 12.5 kW
16.6 - 22.5
12.6 - 18.5
kW
kW
Specified Rating of Power
Supply Cord Kit and Circuit
Protection
Ampere
Temp Rating
40 or 50
194°F (90°C)
50
194°F (90°C)

Hide quick links: