3. Maintenance Schedule
Your PurePressure Axis trichome separator is engineered to go the distance. Make
sure to do the following to ensure long term reliability.
★
Preventative v. Reactive
○
Preventive maintenance is based on the theoretical rate of a component's failure and typically occurs before a
failure happens.
○
Reactive maintenance takes place after a problem has occurred and typically costs more money because of down
time.
★
Maintenance schedule:
○
The maintenance schedule for mechanical parts is factored by hours of operation. For this list, we are assuming
the machine is running for a 40 hour work week.
○
A facilities maintenance schedule should be adjusted based on the amount of time the motor is running.
○
Daily:
■
Clean & wipedown
■
Visual inspection
○
Weekly:
■
Inspect hinges & hinge hardware for loose or backed out bolts
○
120 hours: Check belt tension. See belt tensioning instructions for additional detail
○
Monthly:
■
Inspect the interior of the control stand electrical enclosure for moisture
■
Check vertical movement and pivoting for smooth operation.
■
Check filter regulator for condensation.
○
6 Months: Grease hinges
○
20,000 hours (L10 predicted life): Replace bearings, drive belt, motor and gearbox
If you encounter an issue with your Axis that is not described in the following
pages, please contact us at