3. Maintenance Schedule
Your PurePressure Axis trichome separator is engineered to go the distance. Make
sure to do the following to ensure long term reliability.
Preventative v. Reactive
Preventive maintenance is based on the theoretical rate of a component's failure and typically occurs before a
failure happens.
Reactive maintenance takes place after a problem has occurred and typically costs more money because of down
time.
Maintenance schedule:
The maintenance schedule for mechanical parts is factored by hours of operation. For this list, we are assuming
the machine is running for a 40 hour work week.
A facilities maintenance schedule should be adjusted based on the amount of time the motor is running.
Daily:
Clean & wipedown
Visual inspection
Weekly:
Inspect hinges & hinge hardware for loose or backed out bolts
120 hours: Check belt tension. See belt tensioning instructions for additional detail
Monthly:
Inspect the interior of the control stand electrical enclosure for moisture
Check vertical movement and pivoting for smooth operation.
Check filter regulator for condensation.
6 Months: Grease hinges
20,000 hours (L10 predicted life): Replace bearings, drive belt, motor and gearbox
If you encounter an issue with your Axis that is not described in the following