SERIES 35-70
120 VAC Microprocessor Based
Direct Spark Ignition Control
FEATURES
3 Enclosure Configurations
n
Case and Cover - dust and foreign object protection
n
Open Board with Stand-Off's - saves space and cost
n
Potted - protection for washdown and extreme vibration
n
2 Wiring Options – ¼" quick connects and multi-pin connector
n
2 Trial for Ignition Options – 1 and 3 try
n
4 Trial for Ignition Times – 4, 7,10 and 15 seconds
n
(customized timings available)
2 Flame Sense Options –
n
single spark and sense and remote sense
2 Reset Options – thermostat/power off and automatic
n
(1 hour reset)
Diagnostic LED – 3 error codes for accurate troubleshooting
n
Flame Current Test Pins – instant access to circuit
n
for troubleshooting
Polarity Insensitive – reduces chance of miswiring
n
APPLICATIONS
Construction and Agriculture Heaters
n
Crop Dryers
n
Ceramic and Black Body Infrared Heaters
n
Commercial Cooking Equipment
n
Any 120 VAC Gas Burner Application under 400K BTU
n
The 35-70 is a 120 VAC direct spark ignition control
for controlling a gas valve and igniting LP or natural
gas fired equipment and gas burner applications that
provide a 120 VAC operating signal.
The microprocessor circuit design provides precise,
repeatable timing sequences for ignition times and
purge times (pre- and inter-) as well as multiple tries
for ignition, one hour automatic reset and flame sensing
during pre-purge. The on-board diagnostics with LED
output provide assistance with trouble-shooting to
ensure safe and efficient burner operation.
Agency Certifications
Recognized under the Component Program of Underwriters
Laboratories Inc., UL 372, UL 1998 Software
Design certified by CSA International, CAN C22.2 #199-M89
and ANSI Z21.20 Automatic Ignition Systems
FM Approved as both an ignition device and a flame safeguard.
Restricted to single try models without 1 hour reset.
TFI time must be 15 seconds or less.
Downloaded from StockCheck.com
www.fenwalcontrols.com
1-800-FENWAL-1
THE TOTAL SOLUTION FOR
GAS IGNITION CONTROL
Fenwal offers a complete range of ignition
control including:
Ignition Controls
n
Spark and Flame Sense Electrodes
n
Spark and Flame Sense Cables
n
Wiring harnesses
n
Designed, developed and manufactured by Fenwal, these components
integrate seamlessly providing maximum system performance.
Getting Started - Samples
To ensure proper system design and operation, Fenwal provides
sample ignition controls, high-voltage wires and electrodes for trial
and evaluation at no charge. To get you started quickly, Fenwal has
identified our most popular ignition controls, see Page 8. Whether
it is an individual control, complete start-up kit or customized control,
Fenwal is ready to provide your gas ignition solution.
Fenwal Ignition Development Center
Send your equipment to us and we'll design, install and qualify a
control to meet your exact application requirements. Fully equipped
and staffed with trained technicians, the Fenwal Ignition Development
Center has proven extremely beneficial for many customers focused on
product quality and reducing time-to-market for their appliances.
Series 35-70, 120 VAC Direct Spark Ignition Control
®
35.70.02
Page 1

Advertisement

Table of Contents
loading

Summary of Contents for Fenwal 35-70 Series

  • Page 1 (pre- and inter-) as well as multiple tries and evaluation at no charge. To get you started quickly, Fenwal has for ignition, one hour automatic reset and flame sensing identified our most popular ignition controls, see Page 8.
  • Page 2 System Response to Flame Failures the gas valve and go into lockout mode. Fenwal controls are configured with several options for managing MULTI TRIAL MODEL loss of flame. The control will begin the ignition cycle with the...
  • Page 3: Mounting And Wiring

    Weight Case and Cover: 10.1oz WARNING: Operation outside specifications could result in failure of the Fenwal product and other equipment with injury or death to people REMOTE SENSE and damage to property ON-BOARD DIAGNOSTICS The LED will flash on for 0.2 seconds then off for 0.2 seconds to indicate an error condition.
  • Page 4: Proper Electrode Location

    Spring Steel Spring Steel Flame Sense Electrode Kanthal D Kanthal APM Ground Rod Kanthal D Kanthal APM Spark Electrode, High Voltage Kanthal D Kanthal APM Downloaded from StockCheck.com Page 4 Series 35-70, 120 VAC Direct Spark Ignition Control www.fenwalcontrols.com 1-800-FENWAL-1...
  • Page 5 The "Universal" electrodes depicted below are just a sampling of the 1,000 electrode styles available. These electrodes are designed for on-site customization. Cut and bend these to fit your application and then send the formed electrode back for Fenwal to detail or send us a print and we will provide you with a quote and samples.
  • Page 6: Remote Sense

    (“XX”) with the length in inches (“L” dimension). Standard wire lengths are 12, 18, 24, 30, 36, 48, and 60 inches. Example: 05-129864-518 = 18 inches. For other lengths, please contact Fenwal. SPECIFICATIONS: Voltage Rating...
  • Page 7 Delivering the 15K to 25K volts of spark energy from the ignition control to the electrode is a vital element of an ignition system. There are 3 material options and multiple terminal configurations available. Shown are the most popular versions offered by Fenwal.
  • Page 8: How To Order

    MOST COMMON CONFIGURATIONS Fenwal offers any option variation listed in the above part number scheme along with customized configurations to meet your exact application requirements. Because of the numerous options available, models not listed in the table below are made to order.

This manual is also suitable for:

35-705700-00136-705701-50535-705500-03135-705501-10535-705505-11335-705506-115

Table of Contents