Machine Compartment Components (Continued)
NOTES:
Ƀ Engineering Model Numbers with R134a gas - Follow normal
sealed system purging, capturing, brazing and charging
procedures for models: WUW35X15DS01, WUW35X24DS01,
WUW55X15DS01, WUW55X24DS01, WUW55X15HS00, and
WUW55X24HS00.
Ƀ Engineering Model Numbers with R600a gas (new
compressor and PCB) - Follow R600a sealed system purging,
capturing, lokring, and charging procedures outlined in
Service Manual
W11105483
WUW35X24DS02, WUW55X15HS01, and WUW55X24HS01.
Condenser
1. Complete the steps
1-10
removal instructions.
2. Incline the cabinet backward and set blocks under the front
feet. Remove the condenser cover screws. Remove the
condenser cover.
A. Condenser cover
for models: WUW35X15DS02,
from Machine Compartment Cover
A
COMPONENT ACCESS (Cont.)
3. Remove three (3) screws securing the condenser. Remove the
condenser.
A. Condenser
A
n
Wine Center