Troubleshooting - IMER COMBI 250 VA Operating, Maintenance, Spare Parts Manual

Hide thumbs Also See for COMBI 250 VA:
Table of Contents

Advertisement

To clean the tank, disassemble from the machine, lock the
head, hold it by the arms and rinse with a direct water jet (this
is to avoid direct contact of the water with electrical parts),
the proceed with manual cleaning using cloths or brushes.
Take care not to damage cables when replacing the machine
on the tank
Take care not to damage the pump when placing the machine
on the surface
13.6 Blade replacement
The diamond blade is made of material that may be damaged
when subject to high temperatures, and therefore must be
cooled during the work phases.
To replace the blade, proceed as follows:
1.Block axial movement of the cutting head by means of the
handwheels (ref. O fig. 7).
2. Disassemble the front guard (ref.D fig.4).
3. Loosen the locknut by rotating clockwise (left thread), using
a 19 mm wrench.
4. Move the cutting head forward slightly and incline to remove
the blade from its seat.
5 . Ensure that there are no foreign objects between the fixing
flange and diamond blade. During disassembly, avoid use of
tools that could dent or deform the flange.
6 . Insert the new blade proceeding in reverse order of the
operation described at point 4. Take special care to ensure
correct direction of rotation of the diamond blade.
7. Tighten the blade locknut fully down by rotating
anticlockwise (left thread), to a torque of 40 Nm.
13.7 Cleaning the cooling water supply circuit
At regular intervals (or when the flow rate of the blade cooling
water is reduced) clean the cooling water supply circuit. To do
this, disassemble the delivery nozzle (ref. S fig. 4) located
inside the blade guard and clean in water.
Periodically clean the cooling water delivery line between the
pump and valve, (ref.V fig. 7) and blade guard using water.
RESIDUAL CURRENT
CIRCUIT PROTECTION
KIT 230V-COD.1169245
KIT 110V-COD.1169249:
IMER INTERNATIONAL S.p.A.
COMBI 250 VA
S1
Control switch
C1
Capacitor
PE
Earthing cable
N
Neutral line cable
L1
Phase line conductor
M1
Blade motor
M2
Pump motor
Id
Current circuit breaker

14. TROUBLESHOOTING

- CAUTION!!! All maintenance operations must be
performed exclusively with the machine switched off ,
with the selector set to 0 and the power plug
disconnected from the mains.
Problem
Cause
Start button is
- No voltage on
pressed but
power line.
motor does not
- Socket and plug
start.
not fitted correctly.
- RCCB switch not
activated
- Power cable from
plug to panel is
disconnected.
- Electric wire loose
inside motor
terminal board.
- Electric wire loose
inside panel.
- Start switch
faulty.
No delivery of
- Refer to machine cleaning
cooling water
tank cleaning .
to blade.
Blade does not
- Incorrect
cut.
direction of blade
rotation.
- Blade worn.
13
GB
Remedy
- Check power line.
- Fit correctly.
- A ctivate RCCB
ON button.
- Replace cable
- A rrange repairs
by electrician
- A rrange repairs
by electrician.
- Change switch.
- Disassemble
blade and
reposition in the
direction as shown
on the blade label.
- Fit new blade.