Electrical Adjustment Instructions - Emerson SYLVANIA EWV601A Service Manual

Hide thumbs Also See for SYLVANIA EWV601A:
Table of Contents

Advertisement

ELECTRICAL ADJUSTMENT INSTRUCTIONS

General Note: "CBA" is an abbreviation for
"Circuit Board Assembly."
NOTE:
1.Electrical adjustments are required after replacing
circuit components and certain mechanical parts.
It is important to do these adjustments only after
all repairs and replacements have been com-
pleted. Also, do not attempt these adjustments
unless the proper equipment is available.
2.To perform these alignment / confirmation proce-
dures, make sure that the tracking control is set in
the center position: Press either "L5 ? ? " or "K" button
on the remote control unit first, then the "PLAY"
button (Front Panel only).
Test Equipment Required
1.Oscilloscope: Dual-trace with 10:1 probe,
V-Range: 0.001~50V/Div.,
F-Range: DC~AC-20MHz
2.Alignment Tape (FL8A)
Head Switching Position Adjust-
ment
Purpose:
To determine the Head Switching point during
playback.
Symptom of Misadjustment:
May cause Head Switching noise or vertical jitter
in the picture.
Test point
Adj.Point
TP751(V-OUT)
TP302(RF-SW)
(Switching Point)
J177(GND)
(MAIN CBA)
Measurement
Tape
Equipment
FL8A
Oscilloscope
Connections of Measurement Equipment
TP751
Main CBA
J177
TP302
Mode
VR501
PLAY
(SP)
Spec.
6.5H±1H
(412.7µs±60µs)
Oscilloscope
CH1
Trig. (+)
CH1
CH2
Reference Notes:
Play back the Alignment tape and adjust VR501 so
that the V-sync front edge of the CH1 video output
waveform is at the 6.5H(412.7
from the rising edge of the CH2 head switching pulse
waveform.
Input
-----
CH2
1-7-1
Figure 1
EXT. Syncronize Trigger Point
1.0H
6.5H
Switching Pulse
µ
V-Sync
0.5H
s) delayed position
U25NEA

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sylvania kvs600aSylvania ssv6001a

Table of Contents