Electrical Connections; Electrical Connections-4-Wire - Frigidaire GLEQ942CS0 Installation Instructions Manual

Gas & electric dryer
Hide thumbs Also See for GLEQ942CS0:
Table of Contents

Advertisement

GREEN
GROUND
SCREW
GREEN
NEUTRAL
GROUND
WIRE
STRAIN
RELIEF
MOUNTING
BRACKET

ELECTRICAL CONNECTIONS

FOR 3-WIRE SYSTEM
ELECTRIC Dryer
1. Remove the screws securing the terminal block access
cover and the strain relief mounting bracket located on
the back of the dryer upper corner.
2. Install a U.L. approved strain relief into the power cord
entry hole of the mounting bracket. Finger tighten the nut
only at this time.
3. Thread a U.L. approved 30 amp. power cord, NEMA
10-30 type SRDT, through the strain relief.
4. Attach the power cord neutral (center wire) conductor to
the silver colored center terminal on the terminal block.
Tighten the screw securely.
5. Attach the remaining two power cord outer conductors to
the outer brass colored terminals on the terminal block.
Tighten both screws securely.
Do not make a sharp bend or crimp wiring/
conductor at connections.
6. Reattach the strain relief mounting bracket to the back of
the dryer with two screws. Tighten screws securely.
7. Tighten the screws securing the cord restraint firmly
against the power cord.
8. Tighten the strain relief nut securely so that the strain
relief does not turn.
9. Reinstall the terminal block cover.
SILVER TERMINAL
NUT
TIGHTEN NUT
TO THESE
THREADS
POWER CORD
GREEN POWER CORD
GREEN
GROUND WIRE
GROUND
SCREW
GREEN
NEUTRAL
GROUND
WIRE
RED
ELECTRICAL CONNECTIONS
FOR 4-WIRE SYSTEM
ELECTRIC Dryer
1. Remove the screws securing the terminal block access
cover and the strain relief mounting bracket located on
the back of the dryer upper corner.
2. Install a U.L. approved strain relief in the entry hole of
the mounting bracket. Finger tighten the nut only at this
time.
3. Remove the green neutral ground wire from the green
ground screw located above the terminal block.
TYPICAL 4
CONDUCTOR
30 AMP NEMA 14-30 TYPE SRDT OR ST
4. Thread a U.L. approved 30 amp power cord, NEMA 14-30
type ST or SRDT through the strain relief.
5. Attach the green power cord ground wire to the cabinet
with the green ground screw.
6. Attach the white (neutral) power cord conductor from the
power cord and the green ground wire from the dryer
harness to the silver-colored center terminal on the
terminal block. Tighten the screw securely.
7. Attach the red and black power cord conductors to the
outer brass-colored terminals on the terminal block.
Do not make a sharp bend or crimp wiring/
conductor at the connections.
8. Tighten the screws securing the cord restraint firmly
against the power cord.
9. Tighten the strain relief nut securely so the strain relief
does not turn.
10. Reinstall the terminal block access cover.
9
SILVER TERMINAL
TERMINAL BLOCK
TIGHTEN
BLACK
NUT
TO THESE
WHITE
THREADS
NUT
STRAIN
RELIEF
MOUNTING
BRACKET
POWER
CORD
BLACK
WHITE
RED 240V
TYPICAL 4
CONDUCTOR
GREEN

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Glgq942cs0Electric dryerGas dryer

Table of Contents