Electrical Connections; Electrical Connections-4-Wire - Frigidaire GLGR642AS5 Installation Instructions Manual

Gas & electric dryer
Hide thumbs Also See for GLGR642AS5:
Table of Contents

Advertisement

GREEN
GROUND
SCREW
NEUTRAL
GROUND
WIRE
STRAIN
RELIEF
MOUNTING
BRACKET

ELECTRICAL CONNECTIONS

FOR 3-WIRE SYSTEM
Non-Canadian ELECTRIC Dryer
1. Remove the screws securing the terminal block access cover
and the strain relief mounting bracket located on the back
of the dryer upper corner.
2. Install a U.L. approved strain relief into the power cord entry
hole of the mounting bracket. Finger tighten the nut only at
this time.
3. Thread a U.L. approved 30 amp. power cord, NEMA 10-30
Type SRDT, through the strain relief.
4. Attach the power cord neutral (center wire) conductor to
the silver colored center terminal on the terminal block.
Tighten the screw securely.
5. Attach the remaining two power cord outer conductors to
the outer brass colored terminals on the terminal block.
Tighten both screws securely.
Do not make a sharp bend or crimp wiring/
conductor at connections.
6. Reattach the strain relief mounting bracket to the back of
the dryer with two screws. Tighten screws securely.
7. Tighten the screws securing the cord restraint firmly against
the power cord.
8. Tighten the strain relief nut securely so that the strain relief
does not turn.
9. Reinstall the terminal block cover.
SILVER TERMINAL
NUT
TIGHTEN NUT
TO THESE
THREADS
POWER CORD
GREEN POWER CORD
GREEN
GROUND WIRE
GROUND
SCREW
NEUTRAL
GROUND
WIRE
RED
ELECTRICAL CONNECTIONS
FOR 4-WIRE SYSTEM
Non-Canadian ELECTRIC Dryer
1. Remove the screws securing the terminal block access cover
and the strain relief mounting bracket located on the back
of the dryer upper corner.
2. Install a U.L. approved strain relief in the entry hole of the
mounting bracket. Finger tighten the nut only at this time.
3. Remove the ground wire from the green ground screw
located above the terminal block.
TYPICAL 4
CONDUCTOR
RECEPTACLE
30 AMP NEMA 14-30 TYPE SRDT OR ST
30 AMP NEMA 14-30 TYPE SRDT OR ST
30 AMP NEMA 14-30 TYPE SRDT OR ST
30 AMP NEMA 14-30 TYPE SRDT OR ST
30 AMP NEMA 14-30 TYPE SRDT OR ST
4. Thread a U.L. approved 30 amp power cord, NEMA 14-30
type ST or SRDT through the strain relief.
5. Attach the green power cord ground wire to the cabinet
with the green ground screw.
6. Attach the white (neutral) power cord conductor from the
power cord and the ground wire from the dryer harness to
the silver-colored center terminal on the terminal block.
Tighten the screw securely.
7. Attach the red and black power cord conductors to the
outer brass-colored terminals on the terminal block.
Do not make a sharp bend or crimp wiring/
conductor at the connections.
8. Tighten the screws securing the cord restraint firmly against
the power cord.
9. Tighten the strain relief nut securely so the strain relief
does not turn.
10. Reinstall the terminal block access cover.
8
SILVER TERMINAL
TERMINAL BLOCK
TIGHTEN
BLACK
NUT
TO THESE
WHITE
THREADS
NUT
STRAIN
RELIEF
MOUNTING
BRACKET
POWER
CORD
BLACK 240V
WHITE NEUTRAL
RED 240V
TYPICAL 4
CONDUCTOR CORD
GREEN GROUND

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents