Installation (continued)
3
Mounting the light fixture
Align the mounting holes in the backplate (B)
with the two studs (CC).
Insert the two studs (CC) through the backplate
(B), and secure the fixture with the two acorn
nuts (DD).
Restore the power at the fuse or circuit
breaker box.
CC
DD
B
C
4
Testing the light fixture
The sensitivity switch adjusts the amount of distance
that is required to activate the unit. To set to a desired
level of sensitivity:
Turn on the circuit breaker and the light
switch. The sensor has 1-2 minutes warm up
period before it will detect motion. When first
turned on, wait 1-1.5 minutes.
Set the Time switch to the "TEST" position
and the Sensitivity switch to the "M" position.
The lights turn off in about 5 seconds. Keep
in mind a better sensitivity is achieved by
walking across the coverage area, not walking
towards or away from the motion sensor.
Set the sensitivity to the "H" position for a
higher level of sensitivity and "L" for a lesser
level of sensitivity. The reach is approximately
a 30 ft. radius from the motion sensor if set to
the "H" position.
D to D
2" 6"
Test
Time Switch
6
L
M H
PIR Motion
Sensitivity
Switch