1. DESCRIPTION
1.1 K80S HELMET: It is composed of: a fiberglass shell covered with 3 coats of paint,
the last one of which, the most external one, is polyurethane; a lift-up polycarbonate
visor; a polyamide collar which closes efficiently and comfortably round the operator's
neck; a head-band adjustable from 53 to 63 cm (6-5/8 to 7-7/8 hat size).
1.2 BLOWER UNIT: They are composed of an ABS case and a fan unit actuated by an
electric micromotor.
1.3 BREATHING HOSE ASS.Y: It is composed of an ethyl vinyl acetate, convoluted
hose with couplings for helmet – blower unit connection.
1.4 BATTERY ASSEMBLY : It is composed of: a sealed 6V6Ah rechargeable lead-acid
battery.
1.5 BATTERY CHARGER: It is composed of: a stabilized battery charger with electric
cord.
1.6 SP8 CONVERTOR CORD (for T8N).
1.7 CARTRIDGES: ZA2P3 CARTRIDGE (HE/OV): made up of 2 parts: the first of
technical paper and the other of activated carbon. Both parts are packed into a single
plastic housing with covers and seals.
1.8 AIRFLOW INDICATORS: composed of a transparent tube with indicator ball inside.
To check the airflow performance of the respirator it is supplied with, before each use.
2. TECHNICAL CHARACTERISTICS
2.1 K80S (0302009) HELMET:
Shell : Fiberglass - Face shield : Polycarbonate – Head suspension: Polyethylene –
Face shield gasket: polyethylene foam.
Noise level < 80dB.
2.2 BLOWER UNITS:
Blower unit
Type of
N. of
model
filter
filters
T8N
ZA2P3
2
0303038
ZA2P3
2
T9
0303006
2.3 BATTERY ASSEMBLY:
Blower
Type of
Voltage
unit
battery
model
T8N
Rechargeable
6V 6Ah
0303038
Lead acid
Service
T9
machine
12V to 15V
0303006
battery
- Self discharge: 50% of its capacity
in 6 months at 40° C
in 16 months at 20° C
2.4 BATTERY CHARGING:
Blower unit
Charger model
model
BP-6 (0105086)
T8N
0303038
SP8 converter cord
(0105074)
2.5 ZA2P3 CARTRIDGE (HE/OV):
The ZA2P3 combined cartridges are allowed for respiratory protection against
organic vapors and particulates at a high efficiency level.
USER'S INSTRUCTIONS
K80S-T9 - K80S-T8N
POWERED AIR PURIFYING RESPIRATORS
Cartridge
Battery
Power
2 X ZA2P3
Power cord
0309153
0601019
Converter cord
2 X ZA2P3
6V6Ah
0601019
0309064
0105074
Battery charger
2 X ZA2P3
6V6Ah
0105086
0601019
0309064
Voltage
Airflow at
Expected
20°C 60%
micromotor
R.H .-Battery
life
fully charged
l.p.m.
Hours
6
>170
700
12
>170
500
Terminal
Running
Approx.
voltage
time at
battery life
under
20°C
load
Hours
2 years or 300
5.1
>4
cycles
-
-
Charging time
Input
Output
Hours
7V
110V 50/60Hz
900mA
DC
12-24V
7V, 1.2A
Cord
Breathing
hose
0309109
SP8
0309081
0309109
BP-6
0309109
0309081
Before occupational use of these cartridges the employer shall implement a cartridge
change schedule based on objective information or data that will ensure the cartridges
are changed before the end of their service life (as per requirements of the OSHA
1910.134 Respiratory Protection Standard).
Time use limitations:
Replace cartridges in accordance with an established change schedule or earlier if
smell, taste or irritation from contaminants is detected and, in any case, prior to the
expiry date indicated on the label affixed to the cartridge.
(See also label and User's Instructions packed with filter).
IN CASE OF DOUBT REGARDING THE TYPE OR EFFICIENCY OF THE
CARTRIDGES CONTACT KASCO AT kasco@kasco.eu
3. OPERATION
3.1 The blower unit, powered by battery, takes in filtered air and sends it, through the
breathing hose, to the inside of the helmet. The helmet goes into positive over pressure
and the wearer breathes filtered air only. Filtered expired air is expelled through the
diaphragm valves.
3.2 The blower unit may be connected to a tractor or other service machine dash if the
respirator is equipped with an SP8 converter cord,
4. USE
4.1 For the protection of the eyes and respiratory system of the wearer while working in
non I.D.H.L. environments containing dusts, fumes, mists, organic vapors,
pesticides
4.2 LIMITATIONS (FOR RESPIRATORS EQUIPPED WITH ZA2P3 CARTRIDGES)
a) Do not use in atmospheres immediately dangerous to life or health.
b) Do not wear for protection against organic vapors with poor warning properties.
c) Do not wear for protection against organic vapors which generate high heats of
reaction.
d) Max. use concentration shall be lower than the max. concentrations listed on the
User's Instructions sheet packed with the filter, where that concentration produces
atmospheres immediately dangerous to life or health.
e) Do not use with fumigants.
f) Do not use in closed environments (tanks, silos etc.).
g) Do not use in atmospheres containing less than 19.5 % oxygen.
h) Do not use for protection against carbon monoxide (co) or natural gas.
i) Do not use in explosive atmospheres.
5. OPERATING INSTRUCTIONS
5.1a 6V6Ah BATTERY RECHARGING:
(See battery charger use instructions packed with each battery charger)
5.1b 6V6AH BATTERY RECHARGING with SP8 CONVERTOR CORD:
(See also instructions packed with SP8)
Mount socket to tractor dash and connect it to a 12V battery respecting the
-
polarities indicated on the socket.
Connect SP8 Converter plug to the tractor or service machine.
The battery, even if fully charged, can remain connected to the SP8 without it
undergoing damage, if the latter is kept energized.
ALWAYS CHARGE BATTERY AFTER USE.
CHARGE BATTERY WITH THE SUPPLIED BATTERY CHARGER ONLY.
5.2a T8N BLOWER UNIT SET-UP
Slip belt through guides on battery and blower unit.
Plug connection cord to battery on one end and to blower unit on the other and
tighten nuts to ensure contact.
8
Make sure that the unit is functioning and that the fan rotates in a clockwise
direction.
8
Screw filter or filters onto unit.
5.2b T9 BLOWER UNIT SET-UP
Plug converter cord to the blower unit on one end and to the tractor or service
machine dash socket on the other.
Make sure that the blower unit is functioning and that the fan rotates in a
anticlockwise direction.
5.3 HELMET SET-UP:
Remove protective film from visor. The film was applied to preserve the
transparency of the polycarbonate until the moment of use.
IST-USO-0905086
Rev. 4 – 03/10/2016
Airflow
Belt
3-way filter
indicator
connection
0806022
0307021
0309023
0806008
0307021
0307021
0806008
IDP 109
Page 1 of 2
NIOSH
APPROVAL
TC-23C-1562
TC-23C-1572
TC-23C-1572

Advertisement

loading

Summary of Contents for Kasco K80S-T9

  • Page 1 1.5 BATTERY CHARGER: It is composed of: a stabilized battery charger with electric IN CASE OF DOUBT REGARDING THE TYPE OR EFFICIENCY OF THE cord. CARTRIDGES CONTACT KASCO AT kasco@kasco.eu 1.6 SP8 CONVERTOR CORD (for T8N). 1.7 CARTRIDGES: ZA2P3 CARTRIDGE (HE/OV): made up of 2 parts: the first of 3.
  • Page 2 Damage due to misapplication and/or misuse. The liability of KASCO under the foregoing warranty is limited to the repair or replacement at KASCO’s option without charge for labor or materials of any part upon return of the entire respirator or other product or of the particular part to the KASCO factory within the warranty period, at the sole expense of the purchaser, which part shall upon examination appear to the satisfaction of KASCO to have been defective in material or workmanship.
  • Page 3 KASCO Via Romania 12  ‐ 42124 Reggio Emilia ‐ ITALY Tel: +39 0522 308232 ‐ Fax: +39 0522 939803 THESE RESPIRATORS ARE APPROVED ONLY IN THE FOLLOWING CONFIGURATIONS: RESPIRATOR COMPONENTS ALTERNATE ALTERNATE CAUTIONS AND  BLOWER AIRFLOW ALTERNATE TC‐ PROTECTION FACEPIECE - CORD ASS.Y BREATHING UNIT INDICATOR BELT LIMITATIONS HELMET HOSE 23C‐1562 OV/HE X ABCFHIJLMNOP 23C‐1572 OV/HE ABCFHIJLMNOP 1. PROTECTION HE High Efficiency Particulate Air filter for powered air purifying respirators HE ‐ High Efficiency Particulate Air filter for powered air‐purifying respirators...

This manual is also suitable for:

K80s-t8n031306303131410313195