Page 1
Operations Manual Endurance Pro X2 - Dual Heat Semi-automatic Dough Press Model #: DP2010PRDE WWW.PROLUXE.COM Version: 41219...
Page 2
Make sure there is a proper electrical wall outlet located within reach of the Proluxe equipment is a result of the cord and plug attached to the press. highest quality engineering and time- Then place the press in an area that tested design.
Page 3
(A) Pull Pressing Handle for raising and lowering the upper platen. Proluxe shall not be liable for the This action forces the mating of injury, loss or damage, direct or the platens.
2. Counter – Cycle counter counts WARNING the number of applications from In case of power cord damage, 1 to 9999 (see additional Notes – do not attempt to repair or Counter). replace the power cord. Contact the manufacturer or the local 3.
Dough Pressing Operations SETTING CRUST THICKNESS CONTROL: *The thickness is determined by dough Press Only Press & Par Bake weight and temperature setting on each Dough Press Press Temp Temp Product Time Time platen. 150°F 325°F 7-15 Pizza both both seconds seconds platens...
ADDITIONAL NOTES: Temperature No. DPPC1. (See our catalog and price list for information.) Note Note: This spray will not affect Fahrenheit/Centigrade (Celsius) the taste of your crust in any Conversion way. The temperature controller can be programmed to display either 6.
Page 7
International Symbols Preventative Maintenance Suggestions The Proluxe DP2010 machines are relatively maintenance free. For a long and trouble-free life, the following preventative maintenance should be followed: Daily Care: 1. Platens: These platens should only be cleaned with mild soap and warm water then wiped off with a clean, soft cloth or soft sponge.
Page 8
The lubricant used must be USDA H-1 authorized for food machinery. This lubricant can be ordered through Proluxe as part number # 110-002. Please follow these simple instructions: 1. Locate the grease port on the Service Problems: machine.
Page 11
PROLUXE PARTS LIST FOR DP2010RPRDE DP2010RPRDE ITEM # DESCRIPTION QTY. 208 ~ AC HOUSING, MACHINED 1101781542204 LOCK PLUG, 5/8" ID DP17502 CABLE STRAIN RELIEF 3231 SCREW, SOCKET FLAT HEAD,1/4-20 X 3/4 SF142034 HANDLE SOCKET 11016650 NUT, LOCK NUT 1/2-20, DP2300...
Page 12
PROLUXE PARTS LIST FOR DP2010RPRDE DP2010RPRDE ITEM # DESCRIPTION QTY. 208 ~ AC SCREW, SOCKET HEAD 3/8-16 X 3/4 SSH381634 OVERLAY, DIGITAL CONTROL PANEL ODP1300 CONTROL, FACIA PLATE ASSEMBLY 11086027 DIGITAL CONTROL 110178154052 SPACER, NYLON 1/4 110969111 NUT, HEX 6-32...
Page 13
PROLUXE PARTS LIST FOR DP2010RPRDE DP2010RPRDE ITEM # DESCRIPTION QTY. 208 ~ AC CONTACT N/O SCREW TYPE, GE 110101751 SWITCH, MOM P/S OP SCREW ON GE P9XPLOSO BUTTON BLACK MUSHROOM SCREW ON GE P9ARB3N MANUAL, DP2010 MDP2010PRD BUSHING, ALIGNMENT 110415602...
Page 14
PROLUXE PARTS LIST FOR DP2010RPRDE DP2010RPRDE ITEM # DESCRIPTION QTY. 208 ~ AC KITTED, LOWER PLATEN COMPLETE ASSEMBLY 1106132208AK KITTED, PINION GEAR ASSEMBLY 1109360K KITTED, GAS SPRING, 30LB FORCE DP12810K PLDP2010RPRDE RF 032118 CUSTOMER MANUAL...
Page 18
PROLUXE PARTS LIST FOR DP2010LPRDE DP2010LPRDE ITEM # DESCRIPTION QTY. 208 ~ AC HOUSING, MACHINED 1101781542204 LOCK PLUG, 5/8" ID DP17502 CABLE STRAIN RELIEF 3231 SCREW, SOCKET FLAT HEAD,1/4-20 X 3/4 SF142034 HANDLE SOCKET 11016650 NUT, LOCK NUT 1/2-20, DP2300...
Page 19
PROLUXE PARTS LIST FOR DP2010LPRDE DP2010LPRDE ITEM # DESCRIPTION QTY. 208 ~ AC SCREW, SOCKET HEAD 3/8-16 X 3/4 SSH381634 OVERLAY, DIGITAL CONTROL PANEL ODP1300 CONTROL, FACIA PLATE ASSEMBLY 11086027 DIGITAL CONTROL 110178154052 SPACER, NYLON 1/4 110969111 NUT, HEX 6-32...
Page 20
PROLUXE PARTS LIST FOR DP2010LPRDE DP2010LPRDE ITEM # DESCRIPTION QTY. 208 ~ AC CONTACT N/O SCREW TYPE, GE 110101751 SWITCH, MOM P/S OP SCREW ON GE P9XPLOSO BUTTON BLACK MUSHROOM SCREW ON GE P9ARB3N MANUAL, DP2010BZ MDP2010PRD BUSHING, ALIGNMENT 110415602...
Page 21
PROLUXE PARTS LIST FOR DP2010LPRDE DP2010LPRDE ITEM # DESCRIPTION QTY. 208 ~ AC LOWER PLATEN COMPLETE ASSEMBLY 1106132208AK KITTED, PINION GEAR ASSEMBLY 1109360K KITTED, GAS SPRING, 30LB FORCE DP12810K PLDP2010LPRDE RC 032118 CUSTOMER MANUAL...
Page 23
DOUGHPRO DP2000 Trouble Shooting Guide Symptom Probable Cause Action to be Taken Power Button on Digital Controller Power Cord is not plugged in. Plug power cord into wall 's receptacle face is depressed but doesn’t turn and depress power button on controller Circuit Breaker is tripped off in the Reset circuit breaker that the Grill is...
Page 24
DOUGHPRO DP2000 Trouble Shooting Guide Symptom Probable Cause Action to be Taken Heater Platen overheating If the Relay (depending the year of Replace Relay If the Controller's heat- the model) on the coil side are on LED is not lit indicating the receiving 12vdc indicates the controller is working properly.
Exclusions: 1. WOOD / GAS FIRED OVENS: PROLUXE warranty applies to the main body of the oven being steel / refractory and insulation shall be free from defects in materials and workmanship for a period of four years from the date of purchase. The gas equipment shall be free from defects in materials and workmanship for a period of one (1) year from the date of purchase.