Labkotec SET-1000 12 VDC Installation And Operating Instructions Manual

Labkotec SET-1000 12 VDC Installation And Operating Instructions Manual

Level switch for one sensor

Advertisement

Quick Links

Labkotec Oy
Myllyhaantie 6
FI-33960 PIRKKALA
FINLAND
Tel.: +358 29 006 260
Fax: +358 29 006 1260
24.9.2019
Internet: www.labkotec.fi
D15648_E-2
1/14
SET-1000 12 VDC
Level switch for one sensor
Installation and Operating Instructions
Copyright © 2019 Labkotec Oy
We reserve the right for changes without notice

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SET-1000 12 VDC and is the answer not in the manual?

Questions and answers

Summary of Contents for Labkotec SET-1000 12 VDC

  • Page 1 Tel.: +358 29 006 260 Fax: +358 29 006 1260 24.9.2019 Internet: www.labkotec.fi D15648_E-2 1/14 SET-1000 12 VDC Level switch for one sensor Installation and Operating Instructions Copyright © 2019 Labkotec Oy We reserve the right for changes without notice...
  • Page 2: Table Of Contents

    Appendix 2 Electrical parameters ..............13 SYMBOLS Warning / Attention Pay special attention to installations at explosive atmospheres Device is protected by double or reinforced insulation Copyright © 2019 Labkotec Oy 2/14 We reserve the right for changes without notice...
  • Page 3: General

    The SET-1000 itself must be installed in a non- hazardous area. Figure 2. Typical application. High level alarm in a liquid vessel. Copyright © 2019 Labkotec Oy 3/14 We reserve the right for changes without notice...
  • Page 4: Installation

    Only then do the push buttons function properly and the enclosure is tight. Before installation, please read the safety instructions in chapter 6 ! Figure 3. SET-1000 installation and connections of SET/OS2 sensor. Copyright © 2019 Labkotec Oy 4/14 We reserve the right for changes without notice...
  • Page 5: Cabling When Using Cable Junction Box

    Make sure, that the junction box is closed properly. Copyright © 2019 Labkotec Oy 5/14 We reserve the right for changes without notice...
  • Page 6: Cabling When Using Cable Joint

    Figure 6. Cable installation example Figure 7. Figure 8. Installation accessories Level sensor cabling with a cable joint for cable extension. Copyright © 2019 Labkotec Oy 6/14 We reserve the right for changes without notice...
  • Page 7: Operation And Settings

    SET-1000 via its relays. Attention ! Before pressing the Test button, make sure that the change of relay status does not cause hazards elsewhere ! Copyright © 2019 Labkotec Oy 7/14 We reserve the right for changes without notice...
  • Page 8: Altering Settings

    Trigger point of an alarm in the sensor’s sensing element. Trigger level Sensor selection SET/DM3AL sensor or other Labkotec SET series sensor. Buzzer The buzzer can be disabled. The following tasks must only be executed by a person with proper education and knowledge of Ex-i devices.
  • Page 9 – please pay attention to the operational delay. 3. Check the function by lifting the sensor to the air and immersing it back to the medium. Copyright © 2019 Labkotec Oy 9/14 We reserve the right for changes without notice...
  • Page 10: Trouble-Shooting

    3.4 Connect the wire back to the connector. If the problem can not be solved with the above instructions, please contact Labkotec Oy’s local distributor or Labkotec Oy’s service. Attention ! If the sensor is located in an explosive atmosphere, the...
  • Page 11: Repair And Service

    Ex-i devices and is authorized by the manufacturer. In case of queries, please contact Labkotec Oy’s service. SAFETY INSTRUCTIONS SET-1000 level switch must not be installed in explosive atmosphere.
  • Page 12: Appendices

    Year of manufacture xxx x xxxxx xx YY x where YY = year of manufacture See serial number from the type (e.g. 19 = 2019) plate Copyright © 2019 Labkotec Oy 12/14 We reserve the right for changes without notice...
  • Page 13: Appendix 2 Electrical Parameters

    800 m cable in explosion groups IIB or IIC. Feasibility of other cable types and sensors for different distances can be calculated accordingly. Copyright © 2019 Labkotec Oy 13/14 We reserve the right for changes without notice...