  • Page 1 Installation Instructions ELEKTROMAT SI 14.20-25,00 Model: 10002226 10011 -en- Status: 26.03.2021...
  • Page 2 GfA ELEKTROMATEN GmbH & Co. KG Wiesenstraße 81 D-40549 Düsseldorf www.gfa-elektromaten.de info@gfa-elektromaten.de...
  • Page 3: Table Of Contents

    Table of contents General safety information ....................4     Safe operation ......................... 4   Technical Data ........................ 6     Integrated safety brake ....................7     Mechanical installation ....................8     Electrical installation ..................... 12     Limit switch adjustment ....................
  • Page 4: General Safety Information

    The safe operation of the product can only be ensured if it is used as specified. Follow the installation instructions. Observe all specifications, especially warnings, when installing the product in the overall system. GfA is not liable for damage resulting from non-observance of the installation instructions. The resulting overall system must be reassessed for its safety in accordance with applicable standards and directives (e.g.
  • Page 5 Warning - Failure to follow these installation instructions may result in severe injury or death.  Please read these instructions before using the product.  Keep these instructions handy.  Include these instructions when passing on the product to third parties. Warning - Danger from improper use of the product! ...
  • Page 6: Technical Data

    2 Technical Data Type SG 50F Output torque Output speed Output shaft / hollow shaft 25,00 Locking torque moment Safety brake (testhouse/approval number) 14-003612-PR01 Maximum output speed open / close 35 / 20 for frequency inverter operation Supply voltage 3N~ 400 Operating current 2,00 Operating frequency...
  • Page 7: Integrated Safety Brake

    3 Integrated safety brake A safety brake is integrated into the gearbox of this ELEKTROMATEN. The safety brake protects against the door dropping due to breakage or wear of the gear teeth. The safety brake works regardless of the mounting position, speed and rotating direction. It is maintenance-free.
  • Page 8: Mechanical Installation

    4 Mechanical installation Prerequisites The permissible loads on walls, fastenings, mountings and transmission elements must not be exceeded, even for maximum holding torques or locking torques (▶ refer to technical data). Connection elements: ▶ Self-locking connection ▶ Utilize the hole diameter ▶...
  • Page 9 Mounting Eight threads are provided for mounting. ▶ Use at least 2 of these (①). Keys are used to connect to the door shaft. ▶ Use a key that is at least as long as the hollow shaft (②). BAGAD0 1 0 0 1 _Z0 0 2 8 x (M8x16)
  • Page 10 Installation The descriptions below apply to general door specifications. The specifications of the door manufacturer must also be observed during installation. Warning - Potential injury or danger to life!  During installation, be sure to use a lifting device that has a sufficient load- carrying capacity.
  • Page 11 ▶ Attach the drive unit. BAGAE0 1 0 0 3 _Z0 0 3 ▶ Tighten all connection elements (M8) to 25 BAGAE0 1 0 0 6 _Z0 0 2 Nm. Install all other connection elements according to the specifications of the door manufacturer.
  • Page 12: Electrical Installation

    5 Electrical installation Warning - Danger to life from electric current!  Switch the mains OFF and check that the cables are de-energised  Observe the applicable regulations and standards  Make a proper electrical connection  Use suitable tools Performing electrical installation Remove the cover.
  • Page 13: Limit Switch Adjustment

    6 Limit switch adjustment The adjustment of the final limit positions OPEN and CLOSE is described in the instructions for the door control panel.
  • Page 14: Motor Connection

    7 Motor connection Motor X13 Motor plug 8 Alternative motor connection Motor X13 Motor plug...
  • Page 15: Limit Switch Connection

    9 Limit switch connection Thermal contact S10 Emergency manual operation X12 DES connection Safety circuit Channel B (RS485) Ground Channel A (RS485) Safety circuit Supply voltage...
  • Page 16: Emergency Manual Operation (Emergency Hand Crank)

    10 Emergency manual operation (emergency hand crank) The emergency manual operation is designed for opening or closing the door without power supply. Its activation interrupts the control voltage. Electrical operation is no longer possible. Warning – Injuries due to incorrect operation or falling objects! ...
  • Page 17 Warning – Risk of injury due to uncontrolled movements and falling objects! The drive unit could start up unexpectedly and injure people should a wrong emergency hand crank be used. A wrong crank will drop out of the mounting and injure people.
  • Page 18: Completion Of Commissioning / Testing

    11 Completion of commissioning / testing Check the following components and after that, mount all covers. Gearbox Check drive unit for oil loss (a few drops are not critical). Protect output shaft permanently against corrosion. Safety brake in the gearbox The safety brake requires no maintenance or inspection.
  • Page 19 Emergency manual operation Function to be checked in a de-energised state. Carry out functional test only between final limit positions. Limit switches Check the final limit positions by opening and closing the door completely. The safety zone must not be reached. Entire drive unit Note! ...
  • Page 20: Declaration Of Incorporation / Declaration Of Conformity

    EMC Directive 2014/30/EU within the meaning of RoHS Directive 2011/65/EU The following requirements from Appendix I of GfA ELEKTROMATEN GmbH & Co. KG the Machinery Directive 2006/42/EC are met: declare under our sole responsibility that the 1.1.2, 1.1.3, 1.1.5, 1.2.2, 1.2.3, 1.2.6, 1.3.2,...