Advertisement

Quick Links

f
Installation Instructions
ELEKTROMAT
SI 260.5-80,00
Model: 10005218 10012
-en-
Status: 26.03.2021

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ELEKTROMAT SG 186F and is the answer not in the manual?

Questions and answers

Summary of Contents for GFA ELEKTROMAT SG 186F

  • Page 1 Installation Instructions ELEKTROMAT SI 260.5-80,00 Model: 10005218 10012 -en- Status: 26.03.2021...
  • Page 2 GfA ELEKTROMATEN GmbH & Co. KG Wiesenstraße 81 D-40549 Düsseldorf www.gfa-elektromaten.de info@gfa-elektromaten.de...
  • Page 3: Table Of Contents

    Table of contents General safety information ....................4     Safe operation ......................... 4   Technical Data ........................ 6     Integrated safety brake ....................7     Mechanical installation ....................8     Electrical installation ..................... 12     Limit switch adjustment ....................
  • Page 4: General Safety Information

    The safe operation of the product can only be ensured if it is used as specified. Follow the installation instructions. Observe all specifications, especially warnings, when installing the product in the overall system. GfA is not liable for damage resulting from non-observance of the installation instructions. The resulting overall system must be reassessed for its safety in accordance with applicable standards and directives (e.g.
  • Page 5 Warning - Failure to follow these installation instructions may result in severe injury or death.  Please read these instructions before using the product.  Keep these instructions handy.  Include these instructions when passing on the product to third parties. Warning - Danger from improper use of the product! ...
  • Page 6: Technical Data

    2 Technical Data Type SG 186F Output torque 2600 Output speed Output shaft / hollow shaft 80,00 Locking torque moment 8255 Safety brake (testhouse/approval number) 11-003301-PR Maximum output speed open / close 5 / 5 for frequency inverter operation Supply voltage 3~ 400 Operating current 3,90...
  • Page 7: Integrated Safety Brake

    3 Integrated safety brake A safety brake is integrated into the gearbox of this ELEKTROMATEN. The safety brake protects against the door dropping due to breakage or wear of the gear teeth. The safety brake works regardless of the mounting position, speed and rotating direction. It is maintenance-free.
  • Page 8: Mechanical Installation

    4 Mechanical installation Requirements The permissible loads on walls, mountings, connection and transmission elements must not be exceeded even for maximum holding or locking torque (▶ observe technical data). Connection elements ▶ Use self-locking ▶ Use a screw that ▶ Use adequately connection elements with precisely fits the hole.
  • Page 9 Mounting 2 elongated holes are provided for mounting. ▶ Installation is only permitted with an additional torque mount (Ⓑ). Warning – Injury or danger to life possible!  Check installation aid (Ⓐ) before each use and replace it in case of damage. BAGAD0 7 0 0 1 _Z0 0 3...
  • Page 10 Installation The following descriptions refer to a door which is not further defined. The door manufacturer's specifications must also be observed. Warning – Injury or danger to life possible!  Use a lifting device with sufficient load-carrying capacity for installation tasks. ▶...
  • Page 11 ▶ Attach the drive unit. BAGAE0 7 0 0 3 _Z0 0 1 ▶ Remove transport protection. BAGAE0 7 0 0 4 _Z0 0 2 ▶ Tighten all connection elements (M20) with BAGAE0 7 0 0 5 _Z0 0 2 a torque of 380 Nm.
  • Page 12: Electrical Installation

    5 Electrical installation Warning - Danger to life from electric current!  Switch the mains OFF and check that the cables are de-energised  Observe the applicable regulations and standards  Make a proper electrical connection  Use suitable tools Performing electrical installation Remove the cover.
  • Page 13: Limit Switch Adjustment

    6 Limit switch adjustment The adjustment of the final limit positions OPEN and CLOSE is described in the instructions for the door control panel.
  • Page 14: Motor Connection

    7 Motor connection Rectifier EGR Motor X13 Motor plug Spring applied brake 8 Alternative motor connection Rectifier EGR Motor X13 Motor plug Spring applied brake...
  • Page 15: Limit Switch Connection

    9 Limit switch connection Thermal contact S10 Emergency manual operation X12 DES connection Safety circuit Channel B (RS485) Ground Channel A (RS485) Safety circuit Supply voltage...
  • Page 16: Emergency Manual Operation (Hand Chain Operator)

    10 Emergency manual operation (hand chain operator) Emergency manual operation is designed for opening or closing the door without power supply. Its activation interrupts the control voltage. Electrical operation is no longer possible. Warning – Injuries due to incorrect operation! ...
  • Page 17 Switch on by pulling the red handle. Open or close by pulling the chain. Switch off by pulling the green handle.
  • Page 18: Completion Of Commissioning / Testing

    11 Completion of commissioning / testing Check the following components and after that, mount all covers. Gearbox Check drive unit for oil loss (a few drops are not critical). Protect output shaft permanently against corrosion. Safety brake in the gearbox The safety brake requires no maintenance or inspection.
  • Page 19 Emergency manual operation Function to be checked in a de-energised state. Carry out functional test only between final limit positions. Limit switches Check the final limit positions by opening and closing the door completely. The safety zone must not be reached. Brake Warning –...
  • Page 20 Entire drive unit Note!  Have the drive checked annually by a specialist.  Shorter inspection interval for frequently used doors.  Observe the applicable regulations and standards.
  • Page 21: Declaration Of Incorporation / Declaration Of Conformity

    EMC Directive 2014/30/EU within the meaning of RoHS Directive 2011/65/EU The following requirements from Appendix I of GfA ELEKTROMATEN GmbH & Co. KG the Machinery Directive 2006/42/EC are met: declare under our sole responsibility that the 1.1.2, 1.1.3, 1.1.5, 1.2.2, 1.2.3, 1.2.6, 1.3.2,...

This manual is also suitable for:

Elektromat si 260.5-80,0010005218 10012

Table of Contents