APPENDIX A—TROUBLESHOOTING
If any of the following issues are the result of a user falling while connected to the TriRex, the Pivot Point Assembly
must be replaced before returning the unit to service.
PROBLEM
Engagement Arm (6) assembly is resting on the ground (not engaged in the substrate). (FIG A-1)
POSSIBLE CAUSE
Locking Mechanism (7) is engaged and holding the Engagement Arm (6) down.
SOLUTION
Press down on the Engagement Arm (6) and lift up on the Locking Mechanism (7) to allow the
Engagement Arm (7) to return to its resting position. If the Engagement Arm (6) does not have upward pressure
from the Engagement Arm Shock (19), see next step.
POSSIBLE CAUSE
Engagement Arm Shock (19) is bad.
SOLUTION
Replace the Engagement Arm Shock (19).
PROBLEM
3 Ring Attachment Point (15) for fall arrest is not resting flush with the guide box. (FIG A-2)
POSSIBLE CAUSE
Locking Mechanism (7) is engaged.
SOLUTION
Press down on the Engagement Arm (6) and lift up on the Locking Mechanism (7) to allow the
Engagement Arm (6) to return to its resting position.