28 INSTALLATION
4
Check the display for results.
During the test cycle, monitor the Flow Sense™
display on the control panel. If no bars are
displayed, when the cycle ends, the exhaust
system is adequate. If the exhaust system is
severely restricted, the display will show four
bars. Other problems may also be shown with
error codes. Refer to the next page for error
code details and solutions.
NO BARS:
OK
Four bars indicates that the exhaust system is
severely restricted. Have the system checked
immediately, as performance will be poor.
5
End of cycle.
At the end of the test cycle,
The test cycle will end and the dryer will shut off
automatically after a short delay.
• Check the error code before you call for service
Error
Possible
Code
Causes
tE1 or
• Temperature
tE2
sensor failure.
• Humidity
HS
sensor failure.
• Electric dryer
power cord is
not connected
correctly, or
house power
supply is
PS or
incorrect.
PF or
nP
• House fuse is
blown, circuit
breaker has
tripped, or
power outage
has occurred.
FOUR BARS:
RESTRICTED
will display.
Solutions
• Turn off the dryer and
call for service.
• Turn off the dryer and
call for service.
• Check the power
supply or the
connection of the
power cord to the
terminal block. Refer
to the Connecting
Electric Dryers
section of this
manual for complete
instructions.
• Reset circuit breaker
or replace fuse. Do
not increase the fuse
capacity.
If the problem is a
circuit overload, have it
corrected by a qualified
electrician.
• Gas supply or
service turned
gAS
off. (Gas
Model only.)
• Check the duct condition
TM
If the Flow Sense
LED is turned on, check the
exhaust system for restrictions and damage. Repair
or replace the exhaust system as needed.
NOTE
When the dryer is first installed, this test should
be performed to alert you to any existing
problems with the exhaust duct in your home.
However, since the test performed during normal
operation provides more accurate information on
the condition of the exhaust duct than does the
installation test, the number of bars displayed
during the two tests may not be the same.
Do not interrupt the test cycle, as this could result
in inaccurate results.
Even if no bars are displayed during the test
cycle, some restrictions may still be present in the
exhaust system. Refer to the Venting the Dryer
section of this manual for complete exhaust
system and venting requirements.
Your dryer features Flow Sense™, an innovative
sensing system that automatically detects
blockages and restrictions in the dryer ductwork.
Keeping ductwork clean of lint buildup and free
of restrictions allows clothes to dry faster and
reduces energy use.
• Confirm that house
gas shutoff and the
dryer gas shutoff are
both fully open.