Maintenance; Warranty - NuAire AVT Series Installation Manual

Aire-volve twin fans for outdoor use
Table of Contents

Advertisement

Installation Manual
6.0 CONTROL
6.1 LED Indication
PWR
GREEN: Power on & OK. RED: To much power is taken by
peripherals or there is a short circuit in the net cable. Check
the cable and use a junction box (ES-JB) to connect some of
the peripherals
Standby LED on when fan is not running.
Fan 1
GREEN: Fan 1 is running, RED: Fan 1 faulty.
Fan 2
GREEN: Fan 2 is running, RED: Fan 2 faulty.
Heating* GREEN: Heating selected RED: Heating faulty.
Cooling* Not applicable. See note.
Fault
LED on when a fault is present on unit.
Frost*
Not applicable. See note.
TX
LED on when the controller is transmitting data.
RX
LED on when the controller is receiving data.
* The control panel is common to all the Ecosmart products and
will have indicators for functions that are not available in this
particular fan. However these indicators will not be illuminated.
A Commissioning Procedure document (Document No. 671153) is
available on request from Nuaire.
22
Commissioning Panel Details
MIN =
Minimum speed
adjustment
MAX =
Maximum speed
adjustment
SL run on = Switched Live Run-On
Timer adjustment
TRICKLE = Selects trickle running:
0 = off, 1 = selected
TEST =
Test button
6.2 Using Test Button
The test button allows the individual blowers within the unit to be
checked for its operation. If the fan is running already, press the button
once to stop the fan, press again to switch on the standby fan, press
again to stop and so on. The fan will return to normal operation
after 30 seconds.
6.3 Setting Unit Airflow
6.3.1 Maximum Airflow
Ensure the power supply is switched off and that a link wire is
connected from the supply L to the SL terminal. Unplug all items
connected to the 'Net' connectors.
Switch on the power supply. Ensure unit cover is securely attached.
Wait for the fan to complete its self-test operation.
Remove the cover of the units external commissioning box. Measure
the airflow using standard commissioning instruments at a suitable
point in the ductwork. If adjustment is required, rotate the pot marked
'MAX' to obtain the desired airflow.
6.3.2 Minimum Trickle (Nominally 40%)
Repeat the same procedure as for maximum airflow above but without
the link wire between supply L and SL terminal. Ensure the trickle
switch is in the 'ON' position. The adjustment must be made on the pot
marked 'Min'.
The minimum setting (nominally 40%) must be below the maximum
setting, otherwise minimum setting will be automatically set to be the
same as the maximum.
After setting the airflows, re-connect all the items disconnected
previously. Ensure that the cover over the mains terminals is replaced
and that the cover of the controls enclosure is securely fastened.
Nuaire |
Western Industrial Estate
LED indicators
Pwr
Standby
Min
Max
SL run on
Fan 1
Fan 2
Heating
Cooling
Fault
0
1
Frost
Tx
Trickle
Test
Rx
|
|
| nuaire.co.uk
Caerphilly
CF83 1NA

7.0 MAINTENANCE

It is important that maintenance checks are recorded and that the
schedule is always adhered to, in all cases, the previous report should
be referred to.
7.1 Routine Maintenance
•Clean all areas of unit and treat any areas of corrosion.
•Check all access doors for leakage and if necessary locks should be
adjusted and any replacement gasket materials should be replaced
as required.
7.2 Annually
•Thoroughly inspect the unit and its components for corrosion,
acting immediately to treat/restore any damaged areas.
•All electrical terminals within the unit should be tightened.
•Check all earth connections.
•Check control dampers blades.
•Check operation of damper actuators and linkages and adjust as
necessary.

8.0 WARRANTY

The 5 year warranty starts from the day of delivery and includes parts
and labour for the first year. The remaining period covers replacement
parts only.
This warranty is void if the equipment is modified without
authorisation, is incorrectly applied, misused, disassembled, or not
installed, commissioned and maintained in accordance with the details
contained in this manual and general good practice.
The product warranty applies to the UK mainland and in accordance
with Clause 14 of our Conditions of Sale. Customers purchasing from
outside of the UK should contact Nuaire International Sales office for
further details.
Failure to maintain the unit as recommended will invalidate the
warranty.
9.0 END-OF-LIFE AND RECYCLING
Where possible Nuaire use components which can be largely recycled
when the product reaches its end-of-life:
•Fans, motors, controls, actuators, cabling and other electrical
components can be segregated into WEEE recycling streams.
•Sheet metal parts, aluminium extrusion, heating/cooling coils and
other metallic items can be segregated and fully recycled.
•EPP, plastic ducting, nylon corner pieces, plastic heat exchangers,
packaging material and other plastic components can be
segregated into mixed plastic and widely recycled.
•Cardboard packaging, wood, used filters and other paper
components can be largely recycled or fully processed in energy
from waste centres.
•Remaining Items can be further segregated and processed in
accordance with the zero waste hierarchy. Please call After Sales
Support for further information on items not listed above.
Ensure that Nuaire product is made safe from any electrical / water
/ refrigerant supplies before dismantling commences. This work
should only be undertaken by a qualified person in accordance with
local authority regulations and guidelines, taking into account all
site based risks.
27. 10. 20. Document Number 671590
AVT-(R/X)
8