Advertisement

Quick Links

Corning MobileAccess GX System
Tune up procedure
Corning MobileAccess GX System Tune up procedure
Index
1
INTRODUCTION...................................................................................................................... 2
2
PREPARATION ....................................................................................................................... 2
2.1. PERSONAL PREPARATION ............................................................................................... 2
2.2 POSITION AND CONNECTION ........................................................................................... 3
2.3 POWER UP AND INDICATORS ........................................................................................... 4
3. OMT OPERATION .................................................................................................................... 6
3.1 SET IP ADDRESS OF COMPUTER ..................................................................................... 6
3.2 CONNECT DEVICE VIA OMT .............................................................................................. 6
3.3 EQUIPMENT PARAMETERS ............................................................................................... 7
Page1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MobileAccess GX Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for CORNING MobileAccess GX Series

  • Page 1: Table Of Contents

    Corning MobileAccess GX System Tune up procedure Corning MobileAccess GX System Tune up procedure Index INTRODUCTION........................2 PREPARATION ........................2 2.1. PERSONAL PREPARATION ....................2 2.2 POSITION AND CONNECTION ................... 3 2.3 POWER UP AND INDICATORS ................... 4 3. OMT OPERATION ........................6 3.1 SET IP ADDRESS OF COMPUTER ..................
  • Page 2: Introduction

    Corning MobileAccess GX System Tune up procedure 1 INTRODUCTION This document is primarily written for those who are new to Corning MobileAccess GX and wish to tune up the equipment. The document is applicable to below products from Comba. Model number: GX-P19S80A17-40 and GX-P19S80A17-40-DC Corning MobileAccess OCH (Optical Central Hub) is needed to be connected to equip- ment as a system for the entire test.
  • Page 3: Position And Connection

    Corning MobileAccess GX System Tune up procedure 2.2 POSITION AND CONNECTION 1 - Equipment experimental position Equipment shall be placed in stable position during testing, e.g. place on a table or stand on the floor. Be aware of the table shall be firm enough to support the equipment.
  • Page 4: Power Up And Indicators

    Corning MobileAccess GX System Tune up procedure 2.3 POWER UP AND INDICATORS Before power up, please check product voltage requirement, and make sure the equip- ment is with good grounding protection. Warning: Always be caution to voltage safety. Before hands-on operation, check if the equipment is powered off and disconnected from power supply or otherwise will cause personnel injury and equipment damage.
  • Page 5 Corning MobileAccess GX System Tune up procedure COMM 1900MHz SYS_ALM CPL-50dB CPL-50dB 850 MHz EXT_ALM CPL-50dB AUX_5 AUX_6 Diagnostic LEDs of each unit are located on the bottom of enclosure; each indicates the status of a particular function. Identifier Color Indication On –...
  • Page 6: Omt Operation

    Corning MobileAccess GX System Tune up procedure 3. OMT OPERATION 3.1 SET IP ADDRESS OF COMPUTER The equipment default IP address is “192.168.8.101/255.255.255.0” The IP address of computer has to be set in the same subnet. E.g. 192.168.8.10/255.255.255.0 Note: It’s strongly recommended to keep the equipment IP address in default value.
  • Page 7: Equipment Parameters

    Corning MobileAccess GX System Tune up procedure After successful connection, click “OK” in the pop up window. 3.3 EQUIPMENT PARAMETERS Before tuning RF parameter, check equipment property parameters are correctly set. Equipment Property parameters: Serial No.: Identifier of the equipment. Every piece of equipment has a unique ID.
  • Page 8 Corning MobileAccess GX System Tune up procedure Equipment RF Parameters: Equipment RF Switch: All switches are off of new equipment from the factory. Particular switch has to be turned on for real application or RF testing. Service On/Off (ATE) service 1-3: (Manufacturer level control) This switch has the highest priority.
  • Page 9 Corning MobileAccess GX System Tune up procedure Equipment Power: DL Output Max Power service 1-3: This parameter sets the maximum output level of each service. The range is from 16dBm – 47dBm. DL Output Power service 1-3: This is the read only value of the DL power of each service.

Table of Contents