18. Mount file systems on canister B.
• Steps 1–3 are expected to be customer task
• Steps 4–6 are SSR task
• Steps 7–12 are expected to be customer task
• Steps 13–15 are SSR task
• Steps 16–18 are expected to be customer task
Summary
The goal of this procedure is primarily to add a third high-speed adapter into each ESS 3000 canister.
Customer can add supported InfiniBand or Ethernet adapters into the third PCI slot.
• The PCI address is af:00.1
• The adapter type is ConnectX-5 [ConnectX-5 Ex]
Figure 12. Ethernet ports on canister 1 (upper canister)
Figure 13. Ethernet ports on canister 2 (lower canister)
Note: These images show the PCIe ports for two adapters for each canister. The MES upgrade installs the
third adapter with two more ports in the PCIe slot between the original two adapters.
Online adapter MES procedure
1. Prepare canister A (bottom canister slot) for an adapter MES. (Customer task)
a. Determine the node class of the ESS 3000 enclosure where you want to perform MES.
# mmvdisk nodeclass list
b. Display the state of the nodeclass associated with the ESS 3000.
# mmgetstate -N the ESS 3000 nodeclass
Example:
[root@ess3k5a ~]# mmvdisk nodeclass list
node class
--------------------------
ece_nc_1
ess_x86_64_mmvdisk_78E016N
ess_x86_64_mmvdisk_78E05N1
recovery groups
--------------------------
ece_rg_1
ess3k_78E016N
ess3k_78E05N1
Chapter 2. Servicing 31