Calculating the quantity of refrigerant to add
The quantity of additional refrigerant is variable according
to the installation situation. Thus, make sure the outdoor
unit situation before adding refrigerant.
If you install the excessive length of pipe, add additional
refrigerant as 10g or 20g per unit meter ; refer to the table
below.
Refer to the Service Manual for more details on this
operation.
Total connecting
Model
pipe length (L)
AJ040TXJ2KG
LT≤30m
AJ050TXJ2KG
LT≤30m
AJ052TXJ3KG
LT≥30m
AJ068TXJ3KG
LT≤30m
AJ080TXJ4KG
LT≥30m
CAUTION
• The filled-out label must be adhered in the proximity
of the product charging port (e.g. onto the inside of the
stop valve cover).
• Make sure that the total refrigerant charge does not
exceed (A), the maximum refrigerant charge, which
is calculated in the following formula: Maximum
refrigerant charge (A)= factory refrigerant charge (B) +
maximum additional refrigerant charge due to piping
extension (C).
• Here below, the summary table with refrigerant charge
limits for each products.
(Unit:g)
Model
AJ040TXJ2KG/EU
AJ050TXJ2KG/EU
AJ052TXJ3KG/EU
AJ068TXJ3KG/EU
AJ080TXJ4KG/EU
Adding refrigerant
Chargeless
Chargeless
(LT-30m)x10g
Chargeless
(LT-30m)x20g
A
B
C
980
980
0
1180
1180
0
1750
1550
200
2200
2000
200
2800
2000
800
Step 11 Connecting the drain hose to
the outdoor unit
When heating, ice may accumulate. During the process of
defrosting, check if condensation draining is adequate.
For adequate draining, do the following :
1 Insert the drain plug into the drain hole on the
underside of the outdoor unit.
2 Connect the drain hose to the drain plug.
3 Ensure that condensation draining is adequate.
4 Be sure to plug the rest of drain holes not connected
with drain plugs using drain caps.
• When installing the product, make sure that the
rack is not placed under the drain hole.
• If the product is installed in a region of heavy snow,
allow enough separation distance between the
product and the ground.