Optional Speed Sensing Diagram & Calibration - Salsco 810 Operator And Parts Manual

Wood / brush chipper
Table of Contents

Advertisement

CAL #
627XT
6210XT
2
824
8416/25
8635/40
826
8625
30
810
810PTO
810
810PTO
22
813
813XT
40
818
818XT
1.
Set the Calibration
A.
Find the Mag Pick-Up. It is either on the bell housing or on
the impeller shaft.
a. If it is on the Bell Housing call factory with engine
b. If the Mag Pick-Up is on the Impeller Shaft return to the chart
B.
Turn on power to the dial and the meter will light up. You should
see a zero with a dot in the lower right side of the meter. The dot
means the Feed Sensing is on.
a. Press and hold until the meter gets dark then release the left
b. Press and hold the right button until the meter gets dark then
C.
Now hold both buttons in together until the screen is dark and let
them go. You will see CAL (and a #). At this time, press the left
button to lower the number or the right to raise the number until
the number of choice appears. Now press both buttons to say
"OK". Keep pressing both buttons until you get back to the zero
with a dot.
O:\Manuals\810 CHIPPER\810 WOOD..BRUSH CHIPPER P.W. 10.30.2017.doc
SPEED SENSING CALIBRATION
"SMALL" HYD. LIFT CYLS 0330052-N (BEFORE S/N 1519)
"LARGE" HYD. LIFT CYLS 0330053-N (AFTER S/N 1520)
Setting Speed Sensing
model number, and ask for the number of teeth on the
flywheel. That number must be set as the calibration number.
above and plug the calibration number into the meter.
button. You will see the meter read "auto feed off" and the dot
will disappear.
release the button "auto feed on" and the dot will appear
again.
- 22 -