This eliminates the need for high voltage power at the terminal locations. Note: The Ethernet Network must support POE communications. External Readers: The SY-765 has two reader ports to connect external devices such as a Bar code Gun or an Access Control Swipe Reader that could be mounted outside a door.
Host – RS-232 / RS-485 Communications 1.4 Internal Components The SY-765 has two back-up battery modules, one for the real time clock memory and the other for operation during a power failure. The standard memory back-up module is a lithium battery, which will keep the internal clock running and the memory intact, for 30 days during a power failure.
Page 4
1.2 Internal Components The SY-765 has two back-up battery modules, one for the real time clock memory and the other for operation during a power failure. The standard memory back-up module is a lithium battery, which will keep the internal clock running and the memory intact, for 30 days during a power failure.
Note: Do not throw away the box or packing materials. Check the box and the contents for any signs of damage that may have happened during shipment. Carefully unpack and check the contents. The SY-765 package contains: 1 SY-765 terminal Mounting panel/back plate 10 meter serial cable.
2.2 Mounting the Terminal Make sure the unit is unplugged and that it is not connected to the network/PC. Caution: The terminal should not be mounted where it will be exposed to extreme heat or cold, water, steam, violent vibrations, high electromagnetic radiation including high voltage power lines and electrical equipment.
3.0 Terminal Configuration The SY-765 Terminal can be connected to the host computer using either RS-232(Direct), RS-485(LAN), Ethernet including Wi-Fi. 3.1 Entering Technician Mode The SY-765 Terminal contains a built in configuration program called Technician mode.
The terminal can be connected to one of the following communication networks: Ethernet (optional card) - For this type of communication, an IP address is defined for every SY-765 terminal, enabling communication with each terminal in any 10/100 Ethernet network.
Page 9
FPU - Setting the fingerprint unit mode 3.3.1.1 RS-232 Connection The SY-765 terminal can be connected to the host computer via RS-232 with the DB9 Serial Adapter and a serial cable. The maximum supported cable length for the serial cable is currently 50’.
Page 10
3.3.3 Ethernet Settings For this type of communication an IP address is defined for every TA-785 terminal enabling communication with each terminal in any 10/100 Ethernet network. Unless otherwise noted, the default settings in bold on the right should always be used. •...
Page 11
3.3.4 Wi-Fi Card Settings Setting the Wi–Fi network connection is done by entering the parameters into the terminal via the keypad. Some of the parameters are entered in HEX form. To enter the parameters in their HEX form, enter the corresponding HEX value into the terminal.
Page 12
• Set/Reset/Exit: Select S to continue and setup the Wi-Fi settings. Reset Use this menu to reset the Wi-Fi card and to change the password. Exit Use this menu option to exit out of the Network Connection settings. ...
Page 13
User Name User Password • WPA PSK: Set by drilling down and selecting the parameters. WEP PSK Password – enter password. TKIP WEP PSK Password – enter password. CCMP WEP PSK Password – enter password. ...
4.0 Terminal Maintenance 4.1 Recovery from Memory Error MEM CRASH If there is a memory error, a message will appear on the terminal screen. You will need to clear the NO PROG terminal’s memory and return the terminal to the (No Programming) state according to the procedure below.
Page 15
5.0 Field Upgrades and Servicing One of the many features of the SY-765 terminal is the ability to do field upgrades and servicing. This section provides an explanation on how to perform the following upgrades: • Internal Ethernet Card installation •...
Page 16
Line up the pins to the connectors on the board. Slide the pins into the connectors until the board rests on the two screw mounts. Use the image below as a reference for proper card placement. Type B Type F Insert the two screws for the Ethernet card.
Page 17
5.3 Procedure – Internal Wi-Fi Card Installation NOTE: Refer to the section 3.3.4 for additional information on configuration settings for this option. Unplug the power cord from the bottom of the Terminal and allow the unit to shut down after the battery backup takes over.
Page 18
5.4 Procedure – POE Card Installation Warning: These functions should only be performed by qualified personnel only. It requires working with an open unit. Make sure to unplug the unit wherever the instructions call for it. Failure to take the proper precautions may result serious injury or death.
Page 19
Remove the main board from the unit. Remove the screws from the plastic protection cover on the power board. Warning: Be very careful when handling the power board, failure to take proper precautions may result in serious injury or death. Remove the power cable by loosening the 3 screws for the black, white and green wires and pulling them from the connectors.
Page 20
5.6 Procedure – Proximity Reader Installation Unplug the power cord from the bottom of the Terminal and allow the unit to shut down after the battery backup takes over. This will last about 20 seconds. Unscrew and remove the front panel; there are 5 screws on the back side of the terminal. Using the image below as a guide, attach the proximity reader into the unit using the two screws that came with the kit.
Page 21
The Setup should now look like the image below. Replace the front panel, insert the screws inserting the 5 screws and being careful not to over tighten them. Plug the Terminal back into a power source and make sure that the date/time appears in the terminal display - 20 -...
Appendix – A Supervisor Mode You can assign multiple badge numbers to enter into Supervisor mode, but you cannot use these numbers to clock in with. A.1 Adding Transactions Use the following steps to add transactions into the terminal: NOTE: The clock is programmed initially with a supervisor badge of 11111. This badge number will normally be cleared the first time you program the clock if you use different badge numbers or badge lengths for supervisors.
A.2 Diagnostics Mode A.2.1 Guidelines and procedures for Diagnostics Mode: Use the following step to go through the options within the Diagnostics Mode of the terminal: Step 1. Enter the supervisor badge number and press [ENTER]. Step 2. From the menu that appears select (2) Diag (or Diagnostics if no finger reader is installed). Step 3.
D 1.1 Signal Control With the SY-765’s internal relay, the terminal can control a 30 VDC, 1 Amp dry-contact circuit. The signal control relay can be turned on by both a specific employee badge/number for access control or by time of day for bell ringing.
Page 25
Appendix – E External Wiring Diagrams E.1 RS-232 RS-232 uses the DB9 Serial Adapter and a serial cable. Note: Supported distances for cabling is currently 50 feet. - 24 -...
Appendix – E External Connectors HOST RJ-45 (8-pin) RS-232 Signal Value Remarks RS-485 (-TRX) 0-5 Volt RS-485 (+TRX) 0-5 Volt RS – 232 (TXD) -/+15Vdc Standard RS-232 levels RS – 232 (RXD) -/+15Vdc Standard RS-232 levels RJ-45 (8-pin) Ethernet Signal Value Remarks Transmit data...
Page 27
Barcode Reader Signal Value Remarks Data(-) For RS-422 Led 1 Led 2 Led 3 DATA Data +, For RS – 422 - 26 -...