4 Operation / 4.5 Stopping the engine
4.4.3 Failure of speed measuring system

4.5 Stopping the engine

© Copyright 2020 . All rights reserved.
NOTICE
Sealing of the speed sensor
The speed sensor is designed with a sealing lip and does not require
any additional gasket for assembly.
Connect cable connector to speed sensor.
u
Switch on lubricating oil supply to turbocharger.
u
Possible reasons for failure of the speed measuring system are de-
scribed in the chapter Troubleshooting.
CAUTION
Stopping the engine of oil-cooled turbocharger version
Heat in the turbocharger must be dissipated by the further circulating
lubricating oil.
Post-lubricate for 15 ... 20 minutes.
u
Maintain oil pressure of 0.5 ... 1.0 bar for post-lubrication.
u
CAUTION
Stopping the engine of water-cooled turbocharger version
Heat in the turbocharger must be dissipated.
Allow turbocharger cooling water to run for 15 ... 20 minutes after
u
stopping engine.
Allow oil lubrication to continue running until rotor comes to a stop.
u
Further post-lubrication is not required and not recommended.