Pet immune dual technology intrusion detector - duo-mask

Advertisement

SPECIFICHE TECNICHE / SPECIFICATIONS
Alimentazione / Input Voltage
Consumo / Current Drain (Alarm/Stand-By)
Portata in lunghezza / Coverage
Portata in larghezza / Angle
Piroelettrico / PIR
Microonda / Microwave
Lente (fasci e livelli) / Lens (beams and levels)
Segnale emesso / Signal emitted
Durata allarme / Alarm period
Tipo allarme / Alarm Type
Antiapertura / Anti-opening
Antistrisciamento / Creep zone
Contatto di allarme / Alarm Contact
Contatto di tamper / Tamper switch
Temperatura di esercizio / Operating Temperature
Temperatura di stoccaggio / Storage Temperature
RFI Protezione / Protection
Led WALK TEST (MW and PIR)
Cover / Housing
Accessori / Accessories
Dimensioni / Dimensions
*: Non conforme alla Norma EN 50131-2-4
Not Compliant to the EN 50131-2-4
Meets the requirements:
Conforme ai requisiti:
R&TTE 99/5/CE
EN 50131-2-4: 2008
EN 50131-2-4 Grade 2
EN 50131-2-4 Class 2
CEI 79-2: II° Level
Prodotto conforme alla Direttiva 99/5/CE. La dichiarazione di conformità è disponibile presso la nostra sede.
Tutti i ns. prodotti sono conformi ai requisiti richiesti dalla norma CEI 79-2 2°ed. 1998 + Ab 2000.
L'installazione deve essere eseguita a regola d'arte da personale specializzato.
Il produttore declina ogni responsabilità nel caso in cui il prodotto venga manomesso da persone non autorizzate.
Si raccomanda di verificare il corretto funzionamento del sistema d'allarme almeno una volta al mese, tuttavia un sistema
di allarme elettronico affidabile non evita intrusioni, rapine, incendi o altro, ma si limita a diminuire il rischio che tali situa-
zioni si verifichino.
This product comply the 99/5/CE directive. The declaration of conformity is available at our offices.
Our products/systems comply with the essential requirements of EEC directives.
Installation must be carried out following the local installation norms by qualified personnel.
The manufacturer refuses any responsibility when changes or unauthorized repairs are made to the product/system.
It is recommended to test the operation of the alarm product/system at least once a month. Despite frequent testing and
due to, but not limited to, any or all of the following: tampering, electrical or communication disruption or improper use, it
is possible for the product/system to fail to prevent burglary, rubbery, fire or otherwise. A properly installed and maintained
alarm system can only reduce the risk that this happens.
www.amcelettronica.com
Frequenza / Frequency
Mouse 01 Dual Technology - Rev. 1.3
4
9 to 15 Vdc
(26 mA/18.5 mA) @ 13.8 Vdc
14 m
90°
2 elementi / 2 elements
10.525 GHz
29 patterns on 5 levels
1 mW impulsato / pulsed
4 sec.
AND - OR
100 mA - 40 V - 16 Ω
Max 40 mA - 30 Vdc
From -10 °C to +55 °C
From -20 °C to +60 °C
10 V / m (80 /2000 MHz)
ABS
Snodo orientabile / Swivel bracket /
Rotule orientable *
110 x 60 x 46 mm
installation instructions