Automatic Protection - weedingtech FOAMSTREAM L12 User Manual

Hide thumbs Also See for FOAMSTREAM L12:
Table of Contents

Advertisement

L12 – User manual – English (EU/USA) – 15/01/2020 - ISSUE 4

8.7 AUTOMATIC PROTECTION

The L12 automatically responds to protect itself under
certain conditions. These include:
Low diesel – the L12 will shut down completely
Low water – the L12 will shut down completely
Low petrol/gasoline – the L12 will shut down
completely
Low engine oil – the L12 will shut down completely
In the above conditions, whereby the machine has run low
on input fluids, the user simply has to re-fill the required
fluids and then can restart the machine as usual.
The below conditions indicate that there may be a problem
with the machine. Refer to the troubleshooting guide.
High boiler outlet temperature (over 120C/248F) –
the L12 will shut down the boiler.
High system water pressure (over 120 bar/1740 PSI)
– the safety valve will open.
THE L12 SHOULD BE SWITCHED OFF AND CHECKED BY
A COMPETENT SERVICE ENGINEER IF IT DOES NOT
OPERATE AS EXPECTED.
16

Advertisement

Table of Contents
loading

Related Products for weedingtech FOAMSTREAM L12

This manual is also suitable for:

Foamstream l12-019

Table of Contents