Summary of Contents for PerformancePro Artesian Pro Series
Page 1
OWNER’S MANUAL ARTESIAN PRO HIGH RPM PUMPS PUMP MODEL: ________________________ SERIAL #: ____________________________ DATE PURCHASED: ___________________ Retain this information for future reference. For questions regarding installation, operation or maintenance call (503) 356-5888 5976 SE Alexander St., Ste F, Hillsboro, OR 97123 P (503) 356-5888 F (503) 356-1660 E sales@performancepropumps.com WWW.PERFORMANCEPROPUMPS.COM...
Important Safety Instructions Please read all instructions completely before installing or operating the pump. Save this manual for future reference regarding installation, operation, maintenance and troubleshooting of this pump. Please note the safety warning symbols as noted below: This warning symbol indicates the potential for personal injury or damage to the pump! Please be cautious! This symbol indicates a hazard which if not avoided could result WARNING...
Page 3
Understanding priming and pump operation The Basics Your pump is powered by an electric motor that directly a ects your water ow rate. When the electric motor is turned on it utilizes centrifugal force to generate velocity of the water. The water then ows into the strainer pot from the water source, ltering out debris.
Page 4
Ensure the vault is properly ventilated. 6. The pump ports are 3” slip on both the inlet and discharge ports. The Artesian Pro series o ers 2” or 3” tting sizes.
Installation After thorough inspection, carefully remove the pump from the box. Secure the pump on a solid, at foundation. A covered location is always best and care should be taken to ensure adequate ventilation. See installation tips for bene cial tips. Install a ball or swing type check valve as needed to facilitate pump disconnection, ow control and servicing.
Page 6
Electrical Before wiring any part of the motor be sure the power is disconnected. It is recommended that wiring be performed by a licensed electrician or professional serviceperson. WARNING If pump has a factory preinstalled cord, wiring has already been set and this step is not needed; unless voltage change is required in which case the cord will need to be removed and steps followed below.
3. If you are mechanically minded, the option to order bearings and a seal kit from PerformancePro Pumps or your local dealer is available to perform the repair.
Pump Disassembly All moving parts are located in the rear sub-assembly of this pump. Tools required: 1. 3/32 inch Allen wrench 2. 7/16 inch open end wrench 3. 9/16 inch open end wrench 4. Small and large athead screwdrivers 5. #3 Phillips screw driver Rear Sub-assembly 7/8”...
Page 9
Monitor water level in the volute/basket area to ensure water is always present. If the pump has been running with no incoming water ow for more than 15 minutes, shut the system o immediately and call PerformancePro Pumps for technical assistance. WARNING * Handle the mechanical seal with care to protect the polished and lapped faces of the seal from damage.
Page 10
Winterization Winterizing your pump is necessary if freezing temperatures occur in your geographic area for extended periods of time. If freezing tempuratures are not common but may on occassion drop below freezing, it is advised to follow winterization procedure to protect your pump. Freezing tempuratures cause water to expand and may result in damage to the pump, plumbing, and other connected components resulting in costly repairs.
Troubleshooting The following troubleshooting tips support the most common issues. For additional assistance, please contact techhelp@performancepropumps.com or 503-356-5888. PROBLEM KNOWN ISSUE TRY THIS Pump is not priming No water in strainer pot Fill strainer pot with water and close lid. Ensure plumbing valves are open.
Page 12
Parts Clamp Ring Union Hex Bolts (6) 1 1/8” Hex Bolts (4) Assembly 7/8” Bracket o-ring Motor Basket Tailpiece Mechanical Tailpiece Lid o-ring Seal o-ring Union Assembly Slinger Impeller Bracket o-ring Bracket Bore Motor Base Drain plug o-ring & o-ring Volute ITEM DESCRIPTION...
Page 13
Parts 7/8” Hex Bolts (4) Union 1 1/8” Hex Bolts (6) Assembly Bracket Bracket o-ring Diffuser Quick Clamp Set Screws Mechanical Seal Union Assembly Slinger Motor Lid o-ring Bracket Impeller Bore o-ring Set Screw Diffuser Motor Base with Gasket Diffuser o-ring Drain Plug Volute with Gasket...
Performance Data Pump Model: ArtesianPro High Flow Series Impeller: Various Hz: 60 Db: 50 - 65 Horsepower: 1/2 - 5 RPM: 3450 ENC: ODP Date: 11-7-19 For performance that’s OFF THE CHARTS of ordinary pumps! Pump Model: ArtesianPro High Head Series Impeller: Various Hz: 60 Db: 50 - 65...
Limited Warranty This Artesian Pro series product is warranted to the Purchaser (defined herein as the original end user) to be free of defects in construction and workmanship at the time of purchase. In the event this product malfunctions within three years (for fresh water use) or one year (for use with salt water...
PROTECT YOUR INVESTMENT! Exposure to the elements can result in corrosion and reduced service life of your pump. Protect your pump motor from the elements today! * Excellent weather protection * Noise abatement * Easy to assemble * Customizable precut knockout sections * Sturdy construction * Fits Artesian, Artesian 2, ArtesianPro and Cascade series 15”...